Search Results - "Rosol, Rodolphe"
-
1
PPPS-2013: Design and development of a 6.25 kV / 1 kA PFN to supply the new PS Booster distributor magnets
Published in 2013 Abstracts IEEE International Conference on Plasma Science (ICOPS) (01-06-2013)“…Linac4 is an H - ion linear accelerator, intended to replace Linac2 as injector to the PS Booster (PSB). In order to distribute the 160 MeV beam from Linac4 to…”
Get full text
Conference Proceeding -
2
Development and characterisation of self pinch and rod pinch diodes at 1.9 MEV
Published in 2009 IEEE International Conference on Plasma Science - Abstracts (01-06-2009)“…Summary form only given. Angelixl is a CEA flash X-ray facility witch consist of a 1.6 MV Marx generator, a 2 switches transmission line and a self…”
Get full text
Conference Proceeding -
3
Expansion of the radiographic linear transformer driver (LTD) TO 2.5 MV
Published in 2010 Abstracts IEEE International Conference on Plasma Science (01-06-2010)“…Summary form only given. The radiographic linear transformer driver (LTDR) was built as a 1-MV test stand to demonstrate component reliability and the ability…”
Get full text
Conference Proceeding -
4
Negative polarity rod pinch diode experiments on the astertx generator
Published in 2010 Abstracts IEEE International Conference on Plasma Science (01-06-2010)“…ASTERTX is a 6MV Marx+Blumlein X-ray generaton, dedicated to the testing of electrical components. For our experiments, the vacuum diode has been modified in…”
Get full text
Conference Proceeding -
5
Load Line Evaluation of a 1-MV Linear Transformer Driver (LTD)
Published in 2008 IEEE International Power Modulators and High-Voltage Conference (01-05-2008)“…A seven cavity LTD system has been assembled and tested in a voltage adder configuration capable of producing approximately 1-MV into a 7-Omega, critically…”
Get full text
Conference Proceeding -
6
Linear Transformer Driver (LTD) research for radiographic applications
Published in 2011 IEEE Pulsed Power Conference (01-06-2011)“…URSA Minor is a 21-cavity Linear Transformer Driver (LTD) that has been built to evaluate LTD technology as a driver for flash radiography diode research. The…”
Get full text
Conference Proceeding -
7
Testing of a 1-MV linear transformer driver (LTD) for radiographic applications
Published in 2009 IEEE Pulsed Power Conference (01-06-2009)“…A seven cavity LTD accelerator for radiography applications has been tested with a large area electron beam diode. Individual cavities have been tested with a…”
Get full text
Conference Proceeding