Search Results - "Rizal, Conrad"
-
1
Magneto-Optic-Plasmonic Sensors With Improved Performance
Published in IEEE transactions on magnetics (01-02-2021)“…In this article, a novel magneto-optic-plasmonic (MOP) surface plasmon resonance (SPR) effect-based sensor configuration using a conventional mutlilayer…”
Get full text
Journal Article -
2
Microstructure, Surface Plasmon, Magneto-Optic Surface Plasmon, and Sensitivity Properties of Magneto-Plasmonic Co/Au Multilayers
Published in IEEE transactions on magnetics (01-10-2018)“…Micro-structure properties of (Co 1.2 nm/Au 2 nm) <inline-formula> <tex-math notation="LaTeX">\times N = 20 </tex-math></inline-formula> multilayers (MLs)…”
Get full text
Journal Article -
3
Magneto-Optic Surface Plasmon Resonance Ti/Au/Co/Au/Pc Configuration and Sensitivity
Published in Magnetochemistry (01-09-2018)“…Magneto-optic surface plasmon resonance (MOSPR)-based sensors are highly attractive as next-generation biosensors. However, these sensors suffer from oxidation…”
Get full text
Journal Article -
4
Magneto-Optics Effects: New Trends and Future Prospects for Technological Developments
Published in Magnetochemistry (01-09-2022)“…Magneto-optics (MO) is an effervescent research field, with a wide range of potential industrial applications including sensing, theranostics, pharmaceutics,…”
Get full text
Journal Article -
5
Improved Magneto-Optic Surface Plasmon Resonance Biosensors
Published in Photonics (01-09-2018)“…The magneto-optic (MO) characteristics and sensing performance of noble metal (Ag, Au, Cu) or transition metal (Fe, Ni, Co) single layers and Ag/Co or Au/Co…”
Get full text
Journal Article -
6
Development of electrodeposited multilayer coatings: A review of fabrication, microstructure, properties and applications
Published in Applied surface science advances (01-12-2021)“…The demand for robust engineering materials demonstrating good tribological performance under arduous service conditions has forged the development of novel…”
Get full text
Journal Article -
7
Design of a 2 × 4 Hybrid MMI-MZI Configuration with MMI Phase-Shifters
Published in Materials (12-05-2019)“…This paper reports design of a 2 × 4 hybrid multimode interferometer-Mach-zehnder interferometer (MMI-MZI) configuration consiting of compact thermo-optical…”
Get full text
Journal Article -
8
Improved Transition Metal Dichalcogenides-Based Surface Plasmon Resonance Biosensors
Published in Condensed matter (01-06-2019)“…Surface plasmon resonance (SPR) biosensors based on transition metal dichalcogenides (TMDC) materials have shown improved performance in terms of sensitivity,…”
Get full text
Journal Article -
9
Tunable and Sensitive Detection of Cortisol Using Anisotropic Phosphorene with a Surface Plasmon Resonance Technique: Numerical Investigation
Published in Magnetochemistry (01-03-2022)“…Tunable and ultrasensitive surface plasmon resonance (SPR) sensors are highly desirable for monitoring stress hormones such as cortisol, a steroid hormone…”
Get full text
Journal Article -
10
Sensor with combined plasmonic and magnetic activities
Published in Biosensors and bioelectronics. X (01-08-2024)“…Sensors utilizing magneto-optical surface plasmon resonance are gaining increasing scientific and practical attention to detect atmospheric gases and humidity…”
Get full text
Journal Article -
11
Photoluminescence Property of Eu3+ doped CaSiO3 Nano-phosphor with Controlled Grain Size
Published in Colloids and interfaces (01-12-2018)“…A series of Eu3+ doped CaSiO3/SiO2 nano-phosphor powder of controlled grain size, crystalline structure, and chemical composition were synthesized using the…”
Get full text
Journal Article -
12
Surface Plasmon Resonance (SPR) to Magneto-Optic SPR
Published in Condensed matter (01-06-2019)“…In this editorial, a brief background of the surface plasmon resonance (SPR) principle is discussed, followed by several aspects of magneto-optic SPR (MOSPR)…”
Get full text
Journal Article -
13
Ferromagnetic Multilayers: Magnetoresistance, Magnetic Anisotropy, and Beyond
Published in Magnetochemistry (01-06-2016)“…Obtaining highly sensitive ferromagnetic, FM, and nonmagnetic, NM, multilayers with a large room-temperature magnetoresistance, MR, and strong magnetic…”
Get full text
Journal Article -
14
Microstructure, Surface Plasmon, Magneto-optic Surface Plasmon, and Sensitivity Properties of Magneto-plasmonic Co/Au Multilayers
Published 05-12-2021“…IEEE Transactions on Magnetics, vol. 54, no. 10, pp. 1-9, Oct. 2018, Art no. 5300309 Microstructure properties of Co/Au multilayers prepared using dc-magnetron…”
Get full text
Journal Article -
15
Sensitivity comparison of surface plasmon resonance (SPR) and magneto-optic SPR biosensors
Published in European physical journal plus (01-09-2019)“… Sensitivity of a biosensor is one of the most important parameters that determines its performance. It depends on many factors, such as excitation wavelength…”
Get full text
Journal Article -
16
Magnetophotonics for sensing and magnetometry towards industrial applications
Published 04-10-2021“…Magnetic nanostructures sustaining different kinds of optical modes have been used for magnetometry and label-free ultrasensitive refractive index probing,…”
Get full text
Journal Article -
17
Magnetic Anisotropy and Magnetoresistance Properties of Co/Au Multilayers
Published in IEEE transactions on magnetics (01-02-2015)“…We report on the magnetic anisotropy (MA) and magnetoresistance (MR) properties of [Co (t Co )/Au (t Au )] N θ multilayers prepared by changing the incident…”
Get full text
Journal Article -
18
Microstructure and magneto-optical surface plasmon resonance of Co/Au multilayers
Published in Journal of physics communications (01-05-2018)“…Magneto-optical surface plasmon resonance (MOSPR) sensors benefit from a magneto-optic enhancement with respect to surface plasmon resonance (SPR) sensors,…”
Get full text
Journal Article -
19
Magneto-optic SPR-based Biosensors
Published in 2020 Photonics North (PN) (01-05-2020)“…Magneto-optic surface plasmon resonance (SPR) based material are important in developing new type of sensors. In this work, I propose an Ag-rich Ti/Ag/Co/Au…”
Get full text
Conference Proceeding -
20
Tunable and Sensitive Detection of Cortisol using Anisotropic Phosphorene with a Surface Plasmon Resonance Technique: Numerical Investigation
Published 29-11-2021“…Tunable and ultrasensitive surface plasmon resonance (SPR) sensors are highly desirable for monitoring stress hormones such as cortisol, a steroid hormone…”
Get full text
Journal Article