Search Results - "Ream, A K"

Refine Results
  1. 1

    Isolated left ventricular assist as bridge to cardiac transplantation by Starnes, V A, Oyer, P E, Portner, P M, Ramasamy, N, Miller, P J, Stinson, E B, Baldwin, J C, Ream, A K, Wyner, J, Shumway, N E

    “…The electrically driven Novacor implantable left ventricular assist device has been implanted in six patients (four men and two women) since Sept. 7, 1984. In…”
    Get more information
    Journal Article
  2. 2

    The longitudinal distribution of pulmonary vascular resistance during unilateral hypoxia by SIEGEL, L. C, PEARL, R. G, SHAFER, S. L, REAM, A. K, PRIELIPP, R. C

    Published in Anesthesiology (Philadelphia) (01-03-1989)
    “…Pulmonary capillary hydrostatic pressure and the longitudinal distribution of pulmonary vascular resistance (arterial and venous components) can be determined…”
    Get full text
    Journal Article
  3. 3

    Medical errors summit held in September by Ream, K A

    Published in Journal of emergency nursing (01-12-2000)
    Get full text
    Journal Article Conference Proceeding
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9

    Reappraisal of cardiopulmonary bypass with deep hypothermia and circulatory arrest for complex neurosurgical operations by Baumgartner, W A, Silverberg, G D, Ream, A K, Jamieson, S W, Tarabek, J, Reitz, B A

    Published in Surgery (01-08-1983)
    “…Although cardiopulmonary bypass (CPB) with hypothermia and circulatory arrest is routinely used for certain cardiovascular procedures, its advantages have…”
    Get more information
    Journal Article
  10. 10
  11. 11

    A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter by Whalen, P, Ream, A K

    Published in Journal of Clinical Monitoring (01-01-1988)
    “…Oscillometrically determined brachial artery pressures were compared with simultaneous contralateral radial intraarterial pressures in 19 anesthetized adult…”
    Get full text
    Journal Article
  12. 12

    Anesthetic mishaps and the cost of monitoring: a proposed standard for monitoring equipment by Whitcher, C, Ream, A K, Parsons, D, Rubsamen, D, Scott, J, Champeau, M, Sterman, W, Siegel, L

    Published in Journal of Clinical Monitoring (01-01-1988)
    “…Review of insurance data indicates that approximately 1.5 claims are paid per 10,000 anesthetic procedures, a conservative estimate of the incidence of…”
    Get full text
    Journal Article
  13. 13
  14. 14

    Operative treatment of a giant cerebral artery aneurysm with hypothermia and circulatory arrest: report of a case by Silverberg, G D, Reitz, B A, Ream, A K, Taylor, G, Enzmann, D R

    Published in Neurosurgery (01-03-1980)
    “…A patient with a giant left middle cerebral artery aneurysm is presented. Because of previous operations and dense adhesions of the dominant frontal and…”
    Get more information
    Journal Article
  15. 15

    Cutaneous monitoring of systemic PCO2 on patients in the respiratory intensive care unit being weaned from the ventilator by Eletr, S, Jimison, H, Ream, A K, Dolan, W M, Rosenthal, M H

    “…A procedure for measuring the partial pressure of CO2 in equilibrium with the epidermis was developed at Hewlett--Packard Laboratories. It consists of…”
    Get more information
    Journal Article
  16. 16

    A conductive catheter to improve patient safety during cardiac catheterization by Lipton, M J, Ream, A K, Hyndman, B H

    Published in Circulation (New York, N.Y.) (01-12-1978)
    “…A 60 Hz current, as small as 20 microamperemeter (rms) is capable of causing ventricular fibrillation when directly applied to the heart. Significant cost and…”
    Get full text
    Journal Article
  17. 17

    Epidural measurement of intracranial pressure by Ream, A K, Silverberg, G D, Corbin, S D, Schmidt, E V, Fryer, T B

    Published in Neurosurgery (01-07-1979)
    “…Although the measurement of intracranial pressure (ICP) is gaining widespread acceptance, the most desirable method of measurement is disputed. Subdural…”
    Get more information
    Journal Article
  18. 18
  19. 19

    Automating the recording and improving the presentation of the anesthesia record by Ream, A K

    Published in Journal of Clinical Monitoring (01-10-1989)
    “…Although anesthesia records have been kept for over a hundred years, there is still discussion of their value and content. Two uses of the record are widely…”
    Get full text
    Journal Article
  20. 20

    Telemetry of intracranial pressure by Fryer, T B, Corbin, S D, Silverberg, G D, Schmidt, E V, Ream, A K

    “…In the care of patients with abnormal intracranial pressure, it is important to continuously and accurately measure the intracranial pressure so that treatment…”
    Get more information