Search Results - "Ramp, H."

Refine Results
  1. 1

    Elimination of Thermomechanical Noise in Piezoelectric Optomechanical Crystals by Ramp, H, Hauer, B D, Balram, K C, Clark, T J, Srinivasan, K, Davis, J P

    Published in Physical review letters (30-08-2019)
    “…Mechanical modes are a potentially useful resource for quantum information applications, such as quantum-level wavelength transducers, due to their ability to…”
    Get full text
    Journal Article
  2. 2

    Wavelength transduction from a 3D microwave cavity to telecom using piezoelectric optomechanical crystals by Ramp, H., Clark, T. J., Hauer, B. D., Doolin, C., Balram, K. C., Srinivasan, K., Davis, J. P.

    Published in Applied physics letters (27-04-2020)
    “…Microwave-to-optical transduction has received a great deal of interest from the cavity optomechanics community as a landmark application for…”
    Get full text
    Journal Article
  3. 3

    Tunable open-access microcavities for on-chip cavity quantum electrodynamics by Potts, C. A., Melnyk, A., Ramp, H., Bitarafan, M. H., Vick, D., LeBlanc, L. J., Davis, J. P., DeCorby, R. G.

    Published in Applied physics letters (25-01-2016)
    “…We report on the development of on-chip microcavities and show their potential as a platform for cavity quantum electrodynamics experiments. Microcavity arrays…”
    Get full text
    Journal Article
  4. 4

    Turyn-Type Sequences: Classification, Enumeration, and Construction by Best, D., Ðoković, D. Ž., Kharaghani, H., Ramp, H.

    Published in Journal of combinatorial designs (01-01-2013)
    “…Turyn‐type sequences, TT(n), are quadruples of {±1}‐sequences (A;B;C;D), with lengths n,n,n,n−1, respectively, where the sum of the nonperiodic autocorrelation…”
    Get full text
    Journal Article
  5. 5

    A Preliminary Survey of Impression Trays Used in the Fabrication of Fixed Indirect Restorations by Mitchell, Sonya T., Ramp, Merrie H., Ramp, Lance C., Liu, Perng-Ru

    Published in Journal of prosthodontics (01-10-2009)
    “…Purpose: A variety of impression trays are used in the fabrication of fixed indirect restorations. Impressions used in the construction of fixed indirect…”
    Get full text
    Journal Article
  6. 6

    In vitro mechanical property comparison of four resins used for fabrication of provisional fixed restorations by Ireland, Michele F., Dixon, Donna L., Breeding, Larry C., Ramp, Merrie H.

    Published in The Journal of prosthetic dentistry (01-08-1998)
    “…Purpose. This study recorded and compared the flexural elastic moduli and moduli of rupture of four materials (Provipont DC resin, Triad provisional…”
    Get full text
    Journal Article
  7. 7

    Hardness and wear resistance of two resin composites cured with equivalent radiant exposure from a low irradiance LED and QTH light-curing units by Ramp, Lance C, Broome, James C, Ramp, Merrie H

    Published in American journal of dentistry (01-02-2006)
    “…To measure and compare three-body wear and Vickers hardness at depths of 0 mm and 2 mm in two composite resin materials cured with either a low irradiance…”
    Get more information
    Journal Article
  8. 8

    Evaluation of wear: Enamel opposing three ceramic materials and a gold alloy by Ramp, Merrie H., Suzuki, Shiro, Cox, Charles F., Lacefield, William R., Koth, David L.

    Published in The Journal of prosthetic dentistry (01-05-1997)
    “…Statement of problem. The wear of human enamel and of the restorative material is often a critical concern when selecting a restorative material for any given…”
    Get full text
    Journal Article
  9. 9

    Tensile bond strengths of provisional luting agents used with an implant system by Ramp, Merrie H., Dixon, Donna L., Ramp, Lance C., Breeding, Larry C., Barber, Lindsay L.

    Published in The Journal of prosthetic dentistry (01-05-1999)
    “…Statement of problem. Retrievability of cemented implant-supported fixed prostheses is desirable. Retentive strengths of new provisional luting agents have not…”
    Get full text
    Journal Article
  10. 10

    Mutually unbiased weighing matrices by Best, D., Kharaghani, H., Ramp, H.

    Published in Designs, codes, and cryptography (01-08-2015)
    “…Inspired by the many applications of mutually unbiased Hadamard matrices, we study mutually unbiased weighing matrices. These matrices are studied for small…”
    Get full text
    Journal Article
  11. 11

    Vertical Height Loss: An Investigation of Four Restorative Materials Opposing Enamel by Ramp, Merrie H., Ramp, Lance C., Suzuki, Shiro

    Published in Journal of prosthodontics (01-12-1999)
    “…Purpose The objective of this in vitro investigation was to compare the vertical wear produced by cone‐shaped styli of three ceramic restorative materials and…”
    Get full text
    Journal Article
  12. 12
  13. 13

    Tooth structure loss apical to preparations for fixed partial dentures when using self-limiting burs by Ramp, Merrie H., McCracken, Michael S., Mazer, Raquel B.

    Published in The Journal of prosthetic dentistry (01-05-1998)
    “…Statement of problem. Burs with guide pins may be used to limit the depth of tooth preparation for fixed partial dentures. The effects of guide pins on tooth…”
    Get full text
    Journal Article
  14. 14

    Cryogenic Microwave Filter Cavity with a Tunability Greater than 5 GHz by Clark, T. J, Vadakkumbatt, V, Souris, F, Ramp, H, Davis, J. P

    Published 04-10-2018
    “…Rev. Sci. Inst. 89, 114704 (2018) A wide variety of applications of microwave cavities, such as measurement and control of superconducting qubits, magnonic…”
    Get full text
    Journal Article
  15. 15

    Elimination of Thermomechanical Noise in Piezoelectric Optomechanical Crystals by Ramp, H, Hauer, B. D, Balram, K. C, Clark, T. J, Srinivasan, K, Davis, J. P

    Published 16-06-2019
    “…Phys. Rev. Lett. 123, 093603 (2019) Mechanical modes are a potentially useful resource for quantum information applications, such as quantum-level wavelength…”
    Get full text
    Journal Article
  16. 16

    Wavelength transduction from a 3D microwave cavity to telecom using piezoelectric optomechanical crystals by Ramp, H, Clark, T. J, Hauer, B. D, Doolin, C, Balram, K. C, Srinivasan, K, Davis, J. P

    Published 25-04-2020
    “…Appl. Phys. Lett. 116, 174005 (2020) Microwave to optical transduction has received a great deal of interest from the cavity optomechanics community as a…”
    Get full text
    Journal Article
  17. 17

    Coherent Magneto-Optomechanical Signal Transduction and Long-Distance Phase-Shift Keying by Rudd, M. J, Kim, P. H, Potts, C. A, Doolin, C, Ramp, H, Hauer, B. D, Davis, J. P

    Published 16-04-2019
    “…Phys. Rev. Applied 12, 034042 (2019) A transducer capable of converting quantum information stored as microwaves into telecom-wavelength signals is a critical…”
    Get full text
    Journal Article
  18. 18

    Tunable open-access microcavities for on-chip cQED by Potts, C. A, Melnyk, A, Ramp, H, Bitarafan, M. H, Vick, D, LeBlanc, L. J, Davis, J. P, DeCorby, R. G

    Published 13-01-2016
    “…Appl. Phys. Lett. 108, 041103 (2016) We report on the development of on-chip microcavities and show their potential as a platform for cavity quantum…”
    Get full text
    Journal Article
  19. 19

    Thermo-mechanical characterization of on-chip buckled dome Fabry-Perot microcavities by Bitarafan, M. H, Ramp, H, Allen, T. W, Potts, C, Rojas, X, MacDonald, A. J. R, Davis, J. P, DeCorby, R. G

    Published 27-10-2015
    “…J. Opt. Soc. Am. B 32, 1214 (2015) We report on the thermomechanical and thermal tuning properties of curved-mirror Fabry-Perot resonators, fabricated by the…”
    Get full text
    Journal Article
  20. 20

    Turyn-type sequences: Classification, Enumeration and Construction by Best, D, Djokovic, D. Z, Kharaghani, H, Ramp, H

    Published 19-06-2012
    “…J. Combin. Designs 21: 24--35, 2013 Turyn-type sequences, TT(n), are quadruples of {+,-1}-sequences (A;B;C;D), with lengths n,n,n,n-1 respectively, where the…”
    Get full text
    Journal Article