Time Multiplexed Active Neural Probe with 1356 Parallel Recording Sites
Published in Sensors (Basel, Switzerland) (19-10-2017)“…We present a high electrode density and high channel count CMOS (complementary metal-oxide-semiconductor) active neural probe containing 1344 neuron sized…”
Get full text
Journal Article -
2
Dynamic sub-array selection-based energy-efficient localization and tracking method to power implanted medical devices in scattering heterogenous media employing ultrasound
Published in IEEE transactions on biomedical circuits and systems (04-11-2024)“…Ultrasound (US) as a wireless power transfer methodology has drawn considerable attention from the implantable medical devices (IMD) research community…”
Get full text
Journal Article -
3
Neuropixels Data-Acquisition System: A Scalable Platform for Parallel Recording of 10 000+ Electrophysiological Signals
Published in IEEE transactions on biomedical circuits and systems (01-12-2019)“…Although CMOS fabrication has enabled a quick evolution in the design of high-density neural probes and neural-recording chips, the scaling and miniaturization…”
Get full text
Journal Article -
4
A 128-channel neural stimulation and recording ASIC for scalable cortical visual prosthesis
Published in ESSCIRC 2023- IEEE 49th European Solid State Circuits Conference (ESSCIRC) (11-09-2023)“…Blindness affects millions of people around the world, being triggered by various defects within the human visual system. Different kinds of prostheses have…”
Get full text
Conference Proceeding -
5
Modeling and Characterization of Intra-Body Links for a Smart Contact Lens
Published in 2021 IEEE International Symposium on Circuits and Systems (ISCAS) (01-05-2021)“…Modern and miniaturized ASICs enable the development of anatomically constrained applications within the biomedical framework, such as smart contact lenses…”
Get full text
Conference Proceeding -
6
An Artificial Iris ASIC With High Voltage Liquid Crystal Driver, 10-nA Light Range Detector and 40-nA Blink Detector for LCD Flicker Removal
Published in IEEE solid-state circuits letters (2020)“…In a normally functioning eye, the iris controls the pupil diameter to regulate the amount of light reaching the retina. Various iris deficiencies exist,…”
Get full text
Journal Article -
7
An Artificial Iris ASIC with High Voltage Liquid Crystal Driver, 10 nA Light Range Detector and 40 nA Blink Detector for LCD Flicker Removal
Published in 2020 IEEE Symposium on VLSI Circuits (01-06-2020)“…In a functional eye, the iris controls the pupil diameter to regulate the exposure of the retina. While iris deficiencies such as aniridia or leiomyoma can be…”
Get full text
Conference Proceeding -
8
Time multiplexed active neural probe with 678 parallel recording sites
Published in 2016 46th European Solid-State Device Research Conference (ESSDERC) (01-09-2016)“…We present a high density CMOS neural probe with active electrodes (pixels), consisting of dedicated in-situ circuits for signal source amplification. The…”
Get full text