Search Results - "Pradhan, M S"

Refine Results
  1. 1

    A multi-stage machine learning algorithm for estimating personal dose equivalent using thermoluminescent dosimeter by Pathan, Munir S, Pradhan, S M, Selvam, T Palani, Sapra, B K

    Published in Machine learning: science and technology (01-03-2024)
    “…In the present age, marked by data-driven advancements in various fields, the importance of machine learning (ML) holds a prominent position. The ability of ML…”
    Get full text
    Journal Article
  2. 2

    Study of minimum detection limit of TLD personnel monitoring system in India by Sneha, C., Pradhan, S. M., Adtani, M. M.

    Published in Radiation protection dosimetry (01-09-2010)
    “…Personnel monitoring of radiation workers in India is carried out using a thermoluminescence dosemeter (TLD) system based on CaSO4:Dy Teflon TLD disc. The dose…”
    Get full text
    Journal Article
  3. 3

    Hepatitis B vaccination status and needle-stick and sharps-related Injuries among medical school students in Nepal: a cross-sectional study by Bhattarai, Suraj, K C, Smriti, Pradhan, Pranil M S, Lama, Sami, Rijal, Suman

    Published in BMC research notes (03-11-2014)
    “…Hepatitis B is a dreadful infectious disease and a major global health problem. Health-care workers including clinical students are more vulnerable to such…”
    Get full text
    Journal Article
  4. 4

    MACHINE LEARNING ALGORITHMS FOR IDENTIFICATION OF ABNORMAL GLOW CURVES AND ASSOCIATED ABNORMALITY IN CaSO4:DY-BASED PERSONNEL MONITORING DOSIMETERS by Pathan, Munir S, Pradhan, S M, Selvam, T Palani

    Published in Radiation protection dosimetry (16-09-2020)
    “…Abstract In the present study, machine learning (ML) methods for the identification of abnormal glow curves (GC) of CaSO4:Dy-based thermoluminescence…”
    Get full text
    Journal Article
  5. 5

    ESTIMATION OF ACTUAL DOSE BASED ON BAYESIAN PROBABILISTIC APPROACH USING PERSONNEL MONITORING DOSE RECORDS by Pathan, Munir S, Pradhan, S M, Selvam, T Palani

    Published in Radiation protection dosimetry (30-12-2020)
    “…Abstract In this study, the Bayesian probabilistic approach is applied for the estimation of the actual dose using personnel monitoring dose records of…”
    Get full text
    Journal Article
  6. 6

    MAPPING OF WORKPLACE RADIATION FIELDS IN DIAGNOSTIC RADIOLOGY FACILITIES USING PERSONNEL MONITORING TLD BADGES by Srivastava, Kshama, Chakrabarty, Shatabdi, Pai, Rajeshri, Pradhan, S M, Chaubey, Ajay, Selvam, T P, Sapra, B K

    Published in Radiation protection dosimetry (30-12-2020)
    “…Abstract The radiation protection programme is aimed at safe usage of radiation at workplace, ensuring minimum possible dose to radiation workers, patients and…”
    Get full text
    Journal Article
  7. 7

    ESTIMATION OF UNCERTAINTY IN MEASUREMENT OF DOSE EQUIVALENT AT LABORATORY LEVEL USING CASO4 :Dy-BASED TLD BADGE SYSTEM IN INDIA by Pradhan, S M, Datta, D, Pathan, Munir S, Srivastava, Kshama, Selvam, T Palani

    Published in Radiation protection dosimetry (13-06-2020)
    “…Abstract The objective of this paper is to estimate the combined uncertainty in the measurement of dose equivalent at laboratory level using CaSO4:Dy-based…”
    Get full text
    Journal Article
  8. 8

    STUDY OF EFFECT OF CONSECUTIVE HEATING ON THERMOLUMINESCENCE GLOW CURVES OF MULTI-ELEMENT TL DOSEMETER IN HOT GAS-BASED READER SYSTEM by Pathan, Munir S, Pradhan, S M, Datta, D, Selvam, T Palani

    Published in Radiation protection dosimetry (31-12-2019)
    “…The objective of this paper is to study the effect of consecutive heating of TL elements of a thermoluminescence dosemeter (TLD) card in hot N2 gas-based TLD…”
    Get full text
    Journal Article
  9. 9

    Study of Residual TL of CaSO4:Dy-based Thermoluminescence Dosemeter by Sahai, Manish K, Pradhan, S M, Bakshi, A K, Datta, D

    Published in Radiation protection dosimetry (01-12-2017)
    “…Thermoluminescence (TL) signal obtained during second readout of a TL dosemeter disc previously exposed to ionising radiation is termed as residual TL. The…”
    Get full text
    Journal Article
  10. 10

    DEVELOPMENT OF AN ALGORITHM TO ESTIMATE EYE LENS DOSE IN TERMS OF OPERATIONAL QUANTITY Hp(3) USING HEAD TLD BADGE by Madhumita, B, Sneha, C, Dipali, V, Pradhan, S M, Bakshi, A K, Datta, D, Tripathi, S M, Singh, S K

    Published in Radiation protection dosimetry (01-03-2018)
    “…In view of the recommendations of International Commission on Radiological Protection for reduction of the occupational annual dose limit for eye lens from 150…”
    Get full text
    Journal Article
  11. 11
  12. 12

    Successful treatment of Ascites of hepatic origin in Dog by Pradhan, M S, Dakshinkar, N P, Waghaye, U G, Bodkhe, A M

    Published in Veterinary World (01-01-2008)
    “…Detailed clinico-pathological study of a Doberman pinsiner female, 8 years of age confirmed the ascites of hepatic origin. Administration of diuretic, liver…”
    Get full text
    Journal Article
  13. 13

    Paralytic ileus in a cattle by Pradhan, M.S, Waghaye, U.G, Jadhave, S.C

    Published in Veterinary World (01-06-2008)
    “…[Veterinary World 2008; 1(6.000): 180-180]…”
    Get full text
    Journal Article
  14. 14

    Development of a technique for improving coefficient of variation of CaSO4:Dy teflon-based TLD personnel monitoring system in low-dose region by Pradhan, S M, Sneha, C, Sahai, M K, Chougaonkar, M P, Babu, D A R

    Published in Radiation protection dosimetry (01-12-2015)
    “…In view of the importance of zero-dose background (null signal) in influencing the coefficient of variation in low-dose region, a technique for the estimation…”
    Get full text
    Journal Article
  15. 15

    Integrated modeling for assessing climate change impacts on water resources and hydropower potential in the Himalayas by Baniya, Rupesh, Regmi, Ram Krishna, Talchabhadel, Rocky, Sharma, Sanjib, Panthi, Jeeban, Ghimire, Ganesh R., Bista, Sunil, Thapa, Bhesh Raj, Pradhan, Ananta M. S., Tamrakar, Jebin

    Published in Theoretical and applied climatology (01-05-2024)
    “…Regional hydroclimatic variability and change can affect water resources and hydropower generation. It is essential to assess hydropower potential under…”
    Get full text
    Journal Article
  16. 16

    A method of identification of abnormal glow curves in individual monitoring using CaSO4:Dy teflon TLD and hot gas reader by Pradhan, S M, Sneha, C, Adtani, M M

    Published in Radiation protection dosimetry (01-03-2011)
    “…In the present study, a method of identifying abnormal glow curves to electronically screen the glow curves of TL readout is presented. The method is based on…”
    Get full text
    Journal Article
  17. 17

    Response of ionization chamber based pocket dosimeter to beta radiation by Kumar, Munish, Gupta, Anil, Pradhan, S.M., Bakshi, A.K., Chougaonkar, M.P., Babu, D.A.R.

    Published in Applied radiation and isotopes (01-12-2013)
    “…Quantitative estimate of the response of ionization chamber based pocket dosimeters (DRDs) to various beta sources was performed. It has been established that…”
    Get full text
    Journal Article
  18. 18

    A new look at blind test procedures in personnel monitoring by Chandrasekhar, Sneha, Pradhan, S, Bhattacharya, Madhumita, Bakshi, A, Datta, D

    Published in Radiation Protection and Environment (01-01-2019)
    “…In India, a single type of dosimeter is used all over the country for estimation of occupational doses due to X, beta, and gamma radiations. The quality…”
    Get full text
    Journal Article
  19. 19

    Development of an algorithm for evaluating personal doses due to photon fields in terms of operational quantities for TLD badge system in India by Pradhan, S. M., Sneha, C., Chourasiya, G., Adtani, M. M., Tripathi, S. M., Singh, S. K.

    Published in Radiation protection dosimetry (01-09-2009)
    “…In order to evaluate and report the personal doses in terms of personal dose equivalent, the performance of the CaSO4:Dy based thermoluminescence dosemeter…”
    Get full text
    Journal Article
  20. 20

    Seasonal effect on the composition of blood in cattle by Shrikhande, G B, Rode, A M, Pradhan, M S, Satpute, Ashlesha K

    Published in Veterinary World (01-11-2008)
    “…A group of 84 Lactating cows was selected for study. Heamoglobin, blood glucose level, total serum proteins, albumin, globulin, calcium, inorganic phosphorous…”
    Get full text
    Journal Article