Search Results - "Poulsen, Per Rugaard"
-
1
Dynamic Multileaf Collimator Tracking of Respiratory Target Motion Based on a Single Kilovoltage Imager During Arc Radiotherapy
Published in International journal of radiation oncology, biology, physics (01-06-2010)“…Purpose To demonstrate and characterize dynamic multileaf collimator (DMLC) tracking of respiratory moving targets that are spatially localized with a single…”
Get full text
Journal Article -
2
A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided Radiotherapy
Published in International journal of radiation oncology, biology, physics (01-12-2008)“…Purpose To develop a probability-based method for estimating the mean position, motion magnitude, and trajectory of a tumor using cone-beam CT (CBCT)…”
Get full text
Journal Article -
3
Difference between planned and delivered radiotherapy dose to the internal mammary nodes in high-risk breast cancer patients
Published in Physics and imaging in radiation oncology (01-07-2023)“…•The final frame of continuous portal images was used to estimate the delivered dose to the internal mammary nodes.•Delivered internal mammary node V90_CTV…”
Get full text
Journal Article -
4
Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking
Published in International journal of radiation oncology, biology, physics (2011)“…Purpose To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory…”
Get full text
Journal Article -
5
Editorial: Harnessing the potential of FLASH: questions we must address prior to effective clinical translation
Published in Frontiers in oncology (13-11-2024)Get full text
Journal Article -
6
Three-dimensional liver motion tracking using real-time two-dimensional MRI
Published in Medical physics (Lancaster) (01-04-2014)“…Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is…”
Get full text
Journal Article -
7
The first clinical implementation of electromagnetic transponder-guided MLC tracking
Published in Medical physics (Lancaster) (01-02-2014)“…Purpose: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic…”
Get full text
Journal Article -
8
Efficient Interplay Effect Mitigation for Proton Pencil Beam Scanning by Spot-Adapted Layered Repainting Evenly Spread out Over the Full Breathing Cycle
Published in International journal of radiation oncology, biology, physics (01-01-2018)“…To develop and implement a practical repainting method for efficient interplay effect mitigation in proton pencil beam scanning (PBS). A new flexible…”
Get full text
Journal Article -
9
AAPM Task Group 264: The safe clinical implementation of MLC tracking in radiotherapy
Published in Medical physics (Lancaster) (01-05-2021)“…The era of real‐time radiotherapy is upon us. Robotic and gimbaled linac tracking are clinically established technologies with the clinical realization of…”
Get full text
Journal Article -
10
Evaluation of in vitro irradiation setup: Designed for the horizontal beamline at the Danish Centre for Particle Therapy
Published in Acta oncologica (13-02-2024)“…Radiobiological experimental setups are challenged by precise sample positioning along depth dose profile, scattering conditions, and practical difficulties…”
Get full text
Journal Article -
11
The first clinical treatment with kilovoltage intrafraction monitoring (KIM): A real‐time image guidance method
Published in Medical physics (Lancaster) (01-01-2015)“…Purpose: Kilovoltage intrafraction monitoring (KIM) is a real‐time image guidance method that uses widely available radiotherapy technology, i.e., a…”
Get full text
Journal Article -
12
Accuracy of four models and update strategies to estimate liver tumor motion from external respiratory motion
Published in Frontiers in oncology (24-09-2024)“…This study investigates different strategies for estimating internal liver tumor motion during radiotherapy based on continuous monitoring of external…”
Get full text
Journal Article -
13
An experimentally validated couch and MLC tracking simulator used to investigate hybrid couch‐MLC tracking
Published in Medical physics (Lancaster) (01-03-2017)“…Purpose/objective Couch and MLC tracking are two novel techniques to mitigate intrafractional tumor motion on a conventional linear accelerator, but both…”
Get full text
Journal Article -
14
Target position uncertainty during visually guided deep-inspiration breath-hold radiotherapy in locally advanced lung cancer
Published in Radiotherapy and oncology (01-04-2017)“…Abstract Purpose The purpose of this study was to estimate the uncertainty in voluntary deep-inspiration breath-hold (DIBH) radiotherapy for locally advanced…”
Get full text
Journal Article -
15
Spread-out Bragg peak FLASH: quantifying normal tissue toxicity in a murine model
Published in Frontiers in oncology (03-07-2024)“…A favorable effect of ultra-high dose rate (FLASH) radiation on normal tissue-sparing has been indicated in several preclinical studies. In these studies, the…”
Get full text
Journal Article -
16
Intrafraction tumor motion monitoring and dose reconstruction for liver pencil beam scanning proton therapy
Published in Frontiers in oncology (02-03-2023)“…Pencil beam scanning (PBS) proton therapy can provide highly conformal target dose distributions and healthy tissue sparing. However, proton therapy of…”
Get full text
Journal Article -
17
Kilovoltage intrafraction motion monitoring and target dose reconstruction for stereotactic volumetric modulated arc therapy of tumors in the liver
Published in Radiotherapy and oncology (01-06-2014)“…Abstract Purpose To use intrafraction kilovoltage (kV) imaging during liver stereotactic body radiotherapy (SBRT) delivered by volumetric modulated arc therapy…”
Get full text
Journal Article -
18
Image-Based Dynamic Multileaf Collimator Tracking of Moving Targets During Intensity-Modulated Arc Therapy
Published in International journal of radiation oncology, biology, physics (01-06-2012)“…Purpose Intensity-modulated arc therapy (IMAT) enables efficient and highly conformal dose delivery. However, intrafraction motion may compromise the delivered…”
Get full text
Journal Article -
19
A method of dose reconstruction for moving targets compatible with dynamic treatments
Published in Medical physics (Lancaster) (01-10-2012)“…Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to…”
Get full text
Journal Article -
20
Implementation of a New Method for Dynamic Multileaf Collimator Tracking of Prostate Motion in Arc Radiotherapy Using a Single kV Imager
Published in International journal of radiation oncology, biology, physics (01-03-2010)“…To implement a method for real-time prostate motion estimation with a single kV imager during arc radiotherapy and to integrate it with dynamic multileaf…”
Get full text