Search Results - "Phung, T T B"

Refine Results
  1. 1

    DA-DCGAN: An Effective Methodology for DC Series Arc Fault Diagnosis in Photovoltaic Systems by Lu, Shibo, Sirojan, Tharmakulasingam, Phung, B. T., Zhang, Daming, Ambikairajah, Eliathamby

    Published in IEEE access (2019)
    “…DC arc faults, especially series arcing, can occur in photovoltaic (PV) systems and pose a challenging detection and protection problem. Machine learning-based…”
    Get full text
    Journal Article
  2. 2

    Motor Winding Insulation Degradation Under Repetitive Voltage Pulses by Yang, Mengchen, Phung, B. T.

    Published in IEEE access (2024)
    “…Variable speed drives (VSDs) are widely utilized to control motors such as pumps, compressors, fans, etc. However, the endurance of motor winding insulation…”
    Get full text
    Journal Article
  3. 3

    Air Core Transformer Winding Disk Deformation: A Precise Study on Mutual Inductance Variation and Its Influence on Frequency Response Spectrum by Bagheri, Mehdi, Nezhivenko, Svyatoslav, Phung, B. T., Blackburn, Trevor

    Published in IEEE access (01-01-2018)
    “…It is well-known that the deformation of transformer winding can produce detectable changes to the frequency response spectrum compared with a referenced past…”
    Get full text
    Journal Article
  4. 4

    Condition Monitoring Based on Partial Discharge Diagnostics Using Machine Learning Methods: A Comprehensive State-of-the-Art Review by Lu, Shibo, Chai, Hua, Sahoo, Animesh, Phung, B. T.

    “…This paper presents a state-of-the-art review on machine learning (ML) based intelligent diagnostics that have been applied for partial discharge (PD)…”
    Get full text
    Journal Article
  5. 5

    Clinical and Pathogenic Characteristics of Lower Respiratory Tract Infection Treated at the Vietnam National Children’s Hospital by Phung, Thuy T. B., Tran, Sinh T., Nguyen, Phuc T. T., Pham, Hien T.

    “…Lower respiratory tract infections are commonly caused by viruses and cause significant morbidity and mortality among children. Early identification of the…”
    Get full text
    Journal Article
  6. 6

    Dielectric response study of service-aged XLPE cable based on polarisation and depolarisation current method by Morsalin, S., Phung, B. T.

    “…Dielectric response measurement based on the polarisation and depolarisation current (PDC) method is a diagnostic tool commonly employed to the insulation…”
    Get full text
    Journal Article
  7. 7

    Application of UHF Sensors in Power System Equipment for Partial Discharge Detection: A Review by Chai, Hua, Phung, B T, Mitchell, Steve

    Published in Sensors (Basel, Switzerland) (28-02-2019)
    “…Condition monitoring of an operating apparatus is essential for lifespan assessment and maintenance planning in a power system. Electrical insulation is a…”
    Get full text
    Journal Article
  8. 8

    Modeling of dielectric dissipation factor measurement for XLPE cable based on Davidson-Cole model by Morsalin, S., Phung, B. T.

    “…Dielectric response analysis is one approach for the condition assessment of high voltage insulation systems, and measurement of the dissipation factor or tan…”
    Get full text
    Journal Article
  9. 9

    Performance of silicone rubber composites with SiO2 micro/nano-filler under AC corona discharge by Nazir, M. Tariq, Phung, B. T., Hoffman, Mark

    “…Outdoor insulators are often subject to corona discharges and the problem is becoming more prevalent with the increasing use of higher transmission voltage…”
    Get full text
    Journal Article
  10. 10

    Effects of thermal properties on tracking and erosion resistance of micro-ATH/AlN/BN filled silicone rubber composites by Nazir, M. Tariq, Phung, B. T., Yu, Shihu, Li, Shengtao

    “…Silicone rubber is a hydrophobic polymer which is widely employed for high voltage outdoor insulation. The material offers excellent electrical performance…”
    Get full text
    Journal Article
  11. 11

    Accurate Surface Condition Classification of High Voltage Insulators based on Deep Convolutional Neural Networks by Serikbay, Arailym, Bagheri, Mehdi, Zollanvari, Amin, Phung, B. T.

    “…Outdoor insulators in high voltage power lines serve as electrical insulation barriers and mechanical supports for live conductors. They are exposed to…”
    Get full text
    Journal Article
  12. 12

    Sustainable Deep Learning at Grid Edge for Real-Time High Impedance Fault Detection by Sirojan, Tharmakulasingam, Lu, Shibo, Phung, B.T., Zhang, Daming, Ambikairajah, Eliathamby

    Published in IEEE transactions on sustainable computing (01-04-2022)
    “…High impedance faults (HIFs) on overhead power lines are known to cause fires. They are difficult to detect using conventional protection relays because the…”
    Get full text
    Journal Article
  13. 13

    Comparative Damages in RTV Silicone Rubber Exposed to Mineral and Natural Ester Oil by Varun, Jatoth, Mishra, Palash, Phung, B. T., Sarathi, R., Paramane, Ashish, Mondal, Mithun

    “…Room-temperature vulcanized (RTV) silicone rubber is widely used as a protective coating for power transformer bushings due to its exceptional hydrophobicity,…”
    Get full text
    Journal Article
  14. 14

    Measurement and modeling of partial discharge arising from different cavity geometries at very low frequency by Morsalin, S., Phung, B. T., Cavallini, Andrea

    “…In this paper, a comparative study including measurement and modeling of partial discharge for various void geometries (cylinder, block, and prisms) at very…”
    Get full text
    Journal Article
  15. 15

    Resistance against AC corona discharge of micro-ATH/ nano-Al2O3 co-filled silicone rubber composites by Nazir, M. Tariq, Phung, B. T., Shihu Yu, Shengtao Li

    “…Exposure to corona discharge damages the polymeric structure of alumina trihydrate (ATH) filled silicone rubber composite insulators. In this work, an attempt…”
    Get full text
    Journal Article
  16. 16

    Partial discharge localization in transformers using UHF detection method by Sinaga, H. H., Phung, B. T., Blackburn, T. R.

    “…The location of a partial discharge (PD) source inside a transformer can be determined from the time differences of arrival (TDOA) between signals that are…”
    Get full text
    Journal Article
  17. 17
  18. 18

    Online technique for insulation assessment of induction motor stator windings under different load conditions by Malekpour, Majid, Phung, B. T., Ambikairajah, Eliathamby

    “…This paper presents a new condition monitoring system which is able to evaluate and diagnose the stator winding insulation deterioration (SWID) at its initial…”
    Get full text
    Journal Article
  19. 19

    Characterization of Partial Discharge With Polyimide Film in \hbox Considering High Temperature Superconducting Cable Insulation by Du, B. X., Xing, Y. Q., Jin, J. X., Blackburn, T. R., Grantham, C., Phung, B. T., Liu, Z. Y., Rahman, M. F.

    “…High temperature superconducting (HTS) cable has now reached the stage where their application in power systems is in the process of being implemented. Liquid…”
    Get full text
    Journal Article
  20. 20

    Confidence Level Estimation for Advanced Decision-Making in Transformer Short-circuit Fault Diagnosis by Nurmanova, Venera, Akhmetov, Yerbol, Bagheri, Mehdi, Zollanvari, Amin, Phung, B. T., Gharehpetian, Gevork B.

    Published in IEEE transactions on industry applications (01-01-2022)
    “…Frequency response analysis (FRA) is almost certainly the most efficient and well-established method for evaluating the mechanical integrity of transformer…”
    Get full text
    Journal Article