Search Results - "Phlips, B.F."
-
1
Alumina and silicon oxide/nitride sidewall passivation for P- and N-type sensors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-01-2013)“…Silicon detectors normally have an inactive region along the perimeter of the sensor. In this paper we describe a “scribe, cleave, and passivate” (SCP)…”
Get full text
Journal Article -
2
The effect of different dicing methods on the leakage currents of n-type silicon diodes and strip sensors
Published in Solid-state electronics (01-03-2013)“…► We investigate different scribing methods for dicing silicon radiation detectors. ► The leakage current strongly depends on the sidewall quality. ►…”
Get full text
Journal Article -
3
Front-End ASIC for a Silicon Compton Telescope
Published in IEEE transactions on nuclear science (01-08-2008)“…We describe a front-end application specific integrated circuit (ASIC) developed for a silicon Compton telescope. Composed of 32 channels, it reads out signals…”
Get full text
Journal Article -
4
Three-Compton telescope: theory, simulations, and performance
Published in IEEE transactions on nuclear science (01-08-2002)“…The advent of highly segmented gamma-ray detectors with good energy resolution has made a new class of gamma-ray detectors possible. These instruments record…”
Get full text
Journal Article -
5
Germanium strip detector Compton telescope using three-dimensional readout
Published in IEEE transactions on nuclear science (01-08-2003)“…Compton telescopes using two germanium strip detectors with depth resolution have been demonstrated at the Naval Research Laboratory. Depth resolution allows…”
Get full text
Journal Article -
6
Thick silicon strip detector Compton imager
Published in IEEE transactions on nuclear science (01-10-2004)“…We present results obtained with double-sided, thick (2 mm) silicon strip detectors used as a Compton imager. Reconstructed images and spectra from /sup 137/Cs…”
Get full text
Journal Article -
7
Wafer-Bonded Silicon Gamma-Ray Detectors
Published in IEEE transactions on nuclear science (01-04-2008)“…A wafer-bonded silicon power transistor has been shown to function as an x-ray detector. The device consists of two thin device wafers bonded onto either side…”
Get full text
Journal Article -
8
Germanium orthogonal strip detectors with amorphous-semiconductor contacts
Published in IEEE transactions on nuclear science (01-08-2000)“…Germanium orthogonal strip detectors have been produced using amorphous-semiconductor contacts. The amorphous-semiconductor contact fabrication process is…”
Get full text
Journal Article -
9
Development of germanium strip detectors for environmental remediation
Published in IEEE transactions on nuclear science (01-04-2002)“…We present the initial results of the first germanium strip detector array for the imaging and high-resolution spectroscopy of gamma-ray sources. The array…”
Get full text
Journal Article -
10
Front-end ASIC for germanium strip detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-02-2020)“…The characteristics of a recently developed front-end application specific integrated circuit (ASIC) designed for high-purity germanium (HPGe) strip detectors…”
Get full text
Journal Article -
11
Development of a silicon gamma ray spectrometer
Published in IEEE transactions on nuclear science (01-10-2004)“…We present the initial results obtained with double-sided silicon strip detectors used as a nonimaging gamma ray spectrometer. Silicon detectors have…”
Get full text
Journal Article -
12
An advanced Compton telescope based on thick, position-sensitive solid-state detectors
Published in New astronomy reviews (01-02-2004)“…The development of high-resolution, position-sensitive solid-state detectors enables γ-ray instruments with improved sensitivity and imaging capabilities. For…”
Get full text
Journal Article -
13
The construction and performance of the CsI hodoscopic calorimeter for the GLAST beam test engineering module
Published in IEEE transactions on nuclear science (01-08-2001)“…We describe the design, construction, and performance of the CsI hodoscopic calorimeter of the GLAST beam test engineering module (BTEM), a full-size prototype…”
Get full text
Journal Article -
14
Gamma and proton irradiation effects and thermal stability of electrical characteristics of metal-oxide-silicon capacitors with atomic layer deposited Al2O3 dielectric
Published in Solid-state electronics (01-02-2016)“…•Gamma and proton irradiation effects and thermal stability of Al2O3 layers for Si passivation.•MOS capacitors implementing differently processed ALD Al2O3…”
Get full text
Journal Article -
15
Scribe–cleave–passivate (SCP) slim edge technology for silicon sensors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2013)“…We are pursuing scribe–cleave–passivate (SCP) technology of making “slim edge” sensors. Such sensors have only a minimal amount of inactive peripheral region,…”
Get full text
Journal Article -
16
Update on scribe–cleave–passivate (SCP) slim edge technology for silicon sensors: Automated processing and radiation resistance
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-11-2014)“…We pursue scribe–cleave–passivate (SCP) technology for making “slim edge” sensors. The goal is to reduce the inactive region at the periphery of the devices…”
Get full text
Journal Article -
17
Recent results on 3D double sided detectors with slim edges
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2013)“…This paper reports on the first characterization of double sided 3D silicon radiation pixel detectors with slim edges. These detectors consist of a…”
Get full text
Journal Article -
18
200 mm silicon wafer processing for large area strip detectors
Published in 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (01-10-2009)“…We developed large silicon single-sided strip detectors made of 200 mm float-zone Si wafers. The single-sided silicon strip detectors have an effective active…”
Get full text
Conference Proceeding -
19
A liquid scintillator fast neutron double-scatter imager
Published in 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (01-10-2009)“…A liquid scintillator fast neutron imager based on double-scatter neutron detection is in development for the purpose of identifying and locating special…”
Get full text
Conference Proceeding -
20
Gamma-ray imaging with thick position-sensitive silicon detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-11-2006)“…The construction of a prototype Compton imager at the Naval Research Laboratory (NRL) is nearly complete. The instrument is an 8-layer stacked silicon detector…”
Get full text
Journal Article