Search Results - "Pettersen, Fred Johan"
-
1
Detection of inflow obstruction in left ventricular assist devices by accelerometer: An in vitro study
Published in Medical engineering & physics (01-12-2022)“…•An accelerometer detects inflow obstructions in left ventricular assist devices.•Inflow obstructions-related vibrations emerge before the pump flow…”
Get full text
Journal Article -
2
From 3D tissue data to impedance using Simpleware ScanFE+IP and COMSOL Multiphysics – a tutorial
Published in Journal of electrical bioimpedance (23-07-2019)“…Tools such as Simpleware ScanIP+FE and COMSOL Multiphysics allow us to gain a better understanding of bioimpedance measurements without actually doing the…”
Get full text
Journal Article -
3
Detection of inflow obstruction in left ventricular assist devices by accelerometer: A porcine model study
Published in The Journal of heart and lung transplantation (01-08-2023)“…Left ventricular assist devices (LVAD) provide circulatory blood pump support for severe heart failure patients. Pump inflow obstructions may lead to stroke…”
Get full text
Journal Article -
4
Experimental Estimation of Gap Thickness and Electrostatic Forces Between Contacting Surfaces Under Electroadhesion
Published in Advanced intelligent systems (01-04-2024)“…Electroadhesion (EA) is a promising technology with potential applications in robotics, automation, space missions, textiles, tactile displays, and some other…”
Get full text
Journal Article -
5
Accelerometer Detects Pump Thrombosis and Thromboembolic Events in an In vitro HVAD Circuit
Published in ASAIO journal (1992) (01-09-2018)“…Pump thrombosis and stroke are serious complications of left ventricular assist device (LVAD) support. The aim of this study was to test the ability of an…”
Get full text
Journal Article -
6
Detection of Thromboembolic Events and Pump Thrombosis in HeartWare HVAD Using Accelerometer in a Porcine Model
Published in ASAIO journal (1992) (01-01-2020)“…We have recently demonstrated that accelerometer-based pump thrombosis and thromboembolic events detection is feasible in vitro. This article focuses on…”
Get full text
Journal Article -
7
Measuring Blood Pulse Wave Velocity with Bioimpedance in Different Age Groups
Published in Sensors (Basel, Switzerland) (19-02-2019)“…In this project, we have studied the use of electrical impedance cardiography as a possible method for measuring blood pulse wave velocity, and hence be an aid…”
Get full text
Journal Article -
8
Electrosurgery and Temperature Increase in Tissue With a Passive Metal Implant
Published in Frontiers in surgery (12-03-2019)“…During monopolar electrosurgery in patients, current paths can be influenced by metal implants, which can cause unintentional tissue heating in proximity to…”
Get full text
Journal Article -
9
Extracorporeal driveline vibrations to detect left ventricular assist device thrombosis - A porcine model study
Published in The Journal of heart and lung transplantation (01-01-2024)“…Pump thrombosis (PT) and related adverse complications contributed to the HeartWare Ventricular Assist Device (HVAD) market withdrawal. Many patients still…”
Get full text
Journal Article -
10
Bioimpedance monitoring of 3D cell culturing—Complementary electrode configurations for enhanced spatial sensitivity
Published in Biosensors & bioelectronics (15-01-2015)“…A bioimpedance platform is presented as a promising tool for non-invasive real-time monitoring of the entire process of three-dimensional (3D) cell culturing…”
Get full text
Journal Article -
11
Improved Detection Of Thromboembolic Complications In Left Ventricular Assist Device By Novel Accelerometer-Based Analysis
Published in ASAIO journal (1992) (01-09-2022)“…We have previously demonstrated that accelerometer-based vibration analysis detects thromboembolism and pump thrombosis in HeartWare Left Ventricular Assist…”
Get full text
Journal Article -
12
Improved Detection Of Thromboembolic Complications In Left Ventricular Assist Device By Novel Accelerometer-Based Analysis
Published in ASAIO journal (1992) (19-01-2022)“…We have previously demonstrated that accelerometer-based vibration analysis detects thromboembolism and pump thrombosis in HeartWare Left Ventricular Assist…”
Get full text
Journal Article -
13
Electrosurgery and temperature increase in tissue with a passive metal implant
Published in Frontiers in surgery (2019)“…Importance: During monopolar electrosurgery in patients, current paths can be influenced by metal implants, which can cause unintentional tissue heating in…”
Get full text
Journal Article -
14
Development of a miniaturized wireless arbitrary waveform constant current transcutaneous nerve stimulator for wearable diagnostic tests
Published in 2024 19th Biennial Baltic Electronics Conference (BEC) (02-10-2024)“…Transcutaneous nerve stimulators have numerous applications in both therapeutic and diagnostic medicine. Miniaturization of these devices can widen the range…”
Get full text
Conference Proceeding