Search Results - "Peräjärvi, K"
-
1
Radioluminescence yield of alpha particles in air
Published in New journal of physics (09-05-2014)“…Alpha particles can be detected by measuring the radioluminescence light which they induce when absorbed in air. The light is emitted in the near ultraviolet…”
Get full text
Journal Article -
2
Method for the diagnosis of aged plastic radiation portal monitors
Published in Applied radiation and isotopes (01-06-2020)“…The light collection efficiency of plastic scintillator panels used in radiation portal monitors (RPM) declines over time. We present an efficiency calibration…”
Get full text
Journal Article -
3
Reactor Decay Heat in Pu 239 : Solving the γ Discrepancy in the 4–3000-s Cooling Period
Published in Physical review letters (08-11-2010)Get full text
Journal Article -
4
Conversion electron spectrometry of Pu isotopes with a silicon drift detector
Published in Applied radiation and isotopes (01-03-2016)“…An electron spectrometry set-up was built at IRMM consisting of a vacuum chamber with a moveable source holder and windowless Peltier-cooled silicon drift…”
Get full text
Journal Article -
5
High-resolution alpha spectrometry at ambient air pressure—Towards new applications
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2012)“…An approach for alpha spectrometry is introduced that allows measuring alpha spectra at ambient air pressure with energy resolution comparable to measurements…”
Get full text
Journal Article -
6
In-situ alpha spectrometry from air filters at ambient air pressure
Published in Radiation measurements (01-06-2013)“…The effect of collimation to the alpha-particle energy spectra was investigated for two different types of air filters, when the measurements were performed at…”
Get full text
Journal Article -
7
Energy loss measurement of protons in liquid water
Published in Physics in medicine & biology (21-04-2011)“…The proton stopping power of liquid water was, for the first time, measured in the energy range 4.7-15.2 MeV. The proton energies were determined by the…”
Get more information
Journal Article -
8
Characterization of a cryogenic ion guide at IGISOL
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-09-2012)“…A small volume cryogenic ion guide has been characterized at the IGISOL facility, Jyväskylä, as a prototype to verify whether there are any major obstacles to…”
Get full text
Journal Article -
9
A sextupole ion beam guide to improve the efficiency and beam quality at IGISOL
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-11-2008)“…The laser ion source project at the IGISOL facility, Jyväskylä, has motivated the development and construction of an rf sextupole ion beam guide (SPIG) to…”
Get full text
Journal Article -
10
Feasibility of conversion electron spectrometry using a Peltier-cooled silicon drift detector
Published in Journal of radioanalytical and nuclear chemistry (2014)“…A Peltier-cooled silicon drift detector was successfully applied for conversion electron spectrometry. The energy resolution of the detector for 45 keV…”
Get full text
Journal Article -
11
A study of on-line gas cell processes at IGISOL
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (15-03-2010)“…The laser ion source at the IGISOL facility, Jyväskylä, has been used to study the effects of the passage of a primary beam through an ion guide via the…”
Get full text
Journal Article -
12
Off-line studies of the laser ionization of yttrium at the IGISOL facility
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-02-2008)“…A laser ion source is under development at the IGISOL facility, Jyväskylä, in order to address deficiencies in the ion guide technique. The key elements of…”
Get full text
Journal Article -
13
Ultra-high resolution mass separator—Application to detection of nuclear weapons tests
Published in Applied radiation and isotopes (01-03-2010)“…A Penning trap-based purification process having a resolution of about 1 ppm is reported. In this context, we present for the first time a production method…”
Get full text
Journal Article -
14
Determining isotopic distributions of fission products with a Penning trap
Published in The European physical journal. A, Hadrons and nuclei (01-04-2010)“…A novel method to determine independent yields in particle-induced fission employing the ion guide technique and ion counting after a Penning trap has been…”
Get full text
Journal Article -
15
Mass measurements of neutron-deficient nuclides close to A = 80 with a Penning trap
Published in The European physical journal. A, Hadrons and nuclei (01-09-2006)Get full text
Journal Article -
16
Design of an air sampler for a small unmanned aerial vehicle
Published in Radiation protection dosimetry (01-12-2008)“…In the aftermath of a nuclear accident or malevolent act, it is of paramount importance to have the capability to monitor airborne radioactive substances by…”
Get full text
Journal Article -
17
Cryogenic helium as stopping medium for high-energy ions
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-10-2008)“…We have investigated the survival and transport efficiency of 219Rn ions emitted by a 223Ra source in high-density cryogenic helium gas, with ionisation of the…”
Get full text
Journal Article -
18
Comparison of gamma-ray coincidence and low-background gamma-ray singles spectrometry
Published in Applied radiation and isotopes (01-02-2012)“…Aerosol samples have been studied under different background conditions using gamma-ray coincidence and low-background gamma-ray singles spectrometric…”
Get full text
Journal Article -
19
Production of neutron deficient rare isotope beams at IGISOL; on-line and off-line studies
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-08-2004)“…This article reports on recent on-line yield measurements employing the light-ion and heavy-ion reaction-based ion guide systems and new results on α-recoil…”
Get full text
Journal Article -
20
Upgrade and yields of the IGISOL facility
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-10-2008)“…The front end of the Jyväskylä IGISOL facility was upgraded in 2003 by increasing its pumping capacity and by improving the radiation shielding. In late 2005,…”
Get full text
Journal Article