Search Results - "Pelicon, P"

Refine Results
  1. 1

    Influence of surface roughness on the sputter yield of Mo under keV D ion irradiation by Kelemen, M., Schwarz-Selinger, T., Mutzke, A., Balden, M., Vassallo, E., Pedroni, M., Dellasega, D., Passoni, M., Romeo, F., Hakola, A., Pelicon, P., Zaplotnik, R., Markelj, S.

    Published in Journal of nuclear materials (01-11-2021)
    “…In this work the influence of surface roughness on the sputter yield of Mo under keV D ion bombardment was investigated for different impact angles. For this…”
    Get full text
    Journal Article
  2. 2

    The potential of accelerator-based techniques as an analytical tool for forensics: The case of coffee by Chytry, P., Souza, G.M.S., Debastiani, R., dos Santos, C.E.I., Antoine, J.M.R., Banas, A., Banas, K., Calcagnile, L., Chiari, M., Hajdas, I., Molnar, M., Pelicon, P., Pessoa Barradas, N., Quarta, G., Romolo, F.S., Simon, A., Dias, J.F.

    Published in Forensic science international (01-06-2022)
    “…We discuss how different accelerator-based techniques can be employed synergistically as a powerful analytical tool for forensic studies of foodstuff…”
    Get full text
    Journal Article
  3. 3

    Determination of Tritium-Helium-3 differential cross-section in the energy range between 0.6 MeV and 3.3 MeV for tritium depth profiling in solids by Markelj, S., Cvetinović, A., Lipoglavšek, M., Kelemen, M., Čekada, M., Pelicon, P., Payet, M., Grisolia, C.

    Published in Nuclear materials and energy (01-03-2024)
    “…•Determination of the differential cross-sections for the measured 3He+3H nuclear reaction, which has three decaying channels.•First cross-section measurements…”
    Get full text
    Journal Article
  4. 4

    Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe by Vavpetič, P., Pelicon, P., Vogel-Mikuš, K., Grlj, N., Pongrac, P., Jeromel, L., Ogrinc, N., Regvar, M.

    “…Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Deuterium retention in tungsten simultaneously damaged by high energy W ions and loaded by D atoms by Markelj, S., Schwarz-Selinger, T., Založnik, A., Kelemen, M., Vavpetič, P., Pelicon, P., Hodille, E., Grisolia, C.

    Published in Nuclear materials and energy (01-08-2017)
    “…•Deuterium retention measured for the first time in tungsten samples simultaneously damaged by high energy W ions and loaded by D atoms.•Synergistic effects…”
    Get full text
    Journal Article
  7. 7

    Tritium measurements by nuclear reaction analysis using 3He beam in the energy range between 0.7 MeV and 5.1 MeV by Markelj, S., Payet, M., Bernard, E., Lipoglavšek, M., Kelemen, M., Cvetinović, A., Grisolia, C., Pelicon, P.

    Published in Nuclear materials and energy (01-09-2021)
    “…•Production of stable tritiated sample.•Detection of reaction products from nuclear reaction between tritium and 3-helium.•Establishment of a new nuclear…”
    Get full text
    Journal Article
  8. 8

    Laser-induced surface alloying in nanosized Ni/Ti multilayer structures by Petrović, Suzana, Radak, B., Peruško, D., Pelicon, P., Kovač, J., Mitrić, M., Gaković, B., Trtica, M.

    Published in Applied surface science (01-01-2013)
    “…► Different multilayer (Ni/Ti) structures were modified by picoseconds Nd:YAG laser. ► Laser-induced alloying was achieved within the heat affected zone (HAZ)…”
    Get full text
    Journal Article
  9. 9

    In situ nuclear reaction analysis of D retention in undamaged and self-damaged tungsten under atomic D exposure by Markelj, S, Ogorodnikova, O V, Pelicon, P, Schwarz Selinger, T, Vavpeti, P, ade, I

    Published in Physica scripta (01-04-2014)
    “…In situ deuterium depth profile measurements by nuclear reaction analysis (NRA) were performed on undamaged and neutron-like damaged W during D atom exposure…”
    Get full text
    Journal Article
  10. 10
  11. 11

    Study of thermal hydrogen atom interaction with undamaged and self-damaged tungsten by Markelj, S., Ogorodnikova, O.V., Pelicon, P., Schwarz-Selinger, T., Sugiyama, K., Čadež, I.

    Published in Journal of nuclear materials (01-07-2013)
    “…Retention of deuterium in undamaged and damaged polycrystalline tungsten exposed to thermal D beam was studied between 370K and 500K as a function of D…”
    Get full text
    Journal Article
  12. 12

    Analysis of nitrogen-doped ion-beam-deposited hydrogenated diamond-like carbon films using ERDA/RBS, TOF-ERDA and Raman spectroscopy by Čekada, M., Kahn, M., Pelicon, P., Siketić, Z., Radović, I. Bogdanović, Waldhauser, W., Paskvale, S.

    Published in Surface & coatings technology (25-10-2012)
    “…In this work we deposited a series of hydrogenated amorphous carbon (a-C:H) films and nitrogen-doped a-C:H films on silicon substrates using an…”
    Get full text
    Journal Article Conference Proceeding
  13. 13

    The relationship between structure and mechanical properties of hydrogenated amorphous carbon films by Kahn, M., Paskvale, S., Čekada, M., Schöberl, T., Waldhauser, W., Mitterer, C., Pelicon, P., Brandstätter, E.

    Published in Diamond and related materials (01-10-2010)
    “…There is increasing interest in the relations between Raman fit parameters and the mechanical properties of diamond-like carbon films. The present work…”
    Get full text
    Journal Article
  14. 14

    Construction of a confocal PIXE set-up at the Jožef Stefan Institute and first results by Grlj, N., Pelicon, P., Žitnik, M., Vavpetič, P., Sokaras, D., Karydas, A.G., Kanngießer, B.

    “…A new confocal PIXE set-up at the Jožef Stefan Institute in Ljubljana was recently designed and built. It consists of a silicon-drift detector, a specially…”
    Get full text
    Journal Article
  15. 15

    Time-resolved measurements of aerosol elemental concentrations in indoor working environments by Žitnik, M., Kastelic, A., Rupnik, Z., Pelicon, P., Vaupetič, P., Bučar, K., Novak, S., Samardžija, Z., Matsuyama, S., Catella, G., Ishii, K.

    Published in Atmospheric environment (1994) (01-12-2010)
    “…We have measured the elemental concentrations in aerosols with a 2-h time resolution in two different types of working environment: a chemistry laboratory…”
    Get full text
    Journal Article
  16. 16

    Fuel retention study in fusion reactor walls by micro-NRA deuterium mapping by Pelicon, P., Vavpetič, P., Grlj, N., Čadež, I., Markelj, S., Brezinsek, S., Kreter, A., Dittmar, T., Tsitrone, E., Pégourié, B., Languille, P., Rubel, M., Schwarz-Selinger, T.

    “…Nuclear Reaction Analysis (NRA) with a 3He ion beam is a powerful analytical technique for analysis of light elements in thin films. The main motivation for…”
    Get full text
    Journal Article
  17. 17

    Deuterium Inventory in Tore Supra (DITS): 2nd post-mortem analysis campaign and fuel retention in the gaps by Dittmar, T., Tsitrone, E., Pégourié, B., Čadež, I., Pelicon, P., Gauthier, E., Languille, P., Likonen, J., Litnovsky, A., Markelj, S., Martin, C., Mayer, M., Pascal, J.-Y., Pardanaud, C., Philipps, V., Roth, J., Roubin, P., Vavpetič, P.

    Published in Journal of nuclear materials (01-08-2011)
    “…A dedicated study on fuel retention has been launched in Tore Supra, which includes a D wall-loading campaign and the dismantling of the main limiter…”
    Get full text
    Journal Article Conference Proceeding
  18. 18

    Metal analysis with PIXE: The case of Roman military equipment by Šmit, Ž., Pelicon, P., Simčič, J., Istenič, J.

    “…For the analysis of thick metal targets with PIXE, an algorithm for the evaluation of elemental concentrations from the measured X-ray intensities was…”
    Get full text
    Journal Article
  19. 19

    Electron screening in the 1H(7Li,)4He reaction by Lipoglavšek, M., Čadež, I., Markelj, S., Pelicon, P., Vavpetič, P.

    “…We have measured the cross-section for the 1 H( 7 Li, ) 4 He reaction at lithium beam energies from 0.34 to 1.05MeV. Hydrogen was forced by diffusion into Pd…”
    Get full text
    Journal Article
  20. 20

    The performance of the Ljubljana ion microprobe by Simičič, J., Pelicon, P., Budnar, M., Šmit, Ž.

    “…In August 2000 the setup of the Ljubljana ion microprobe, based on OM 150 triplet, has been completed. The beam line is installed at the 10° exit port of the 2…”
    Get full text
    Journal Article