Search Results - "Pappas, Patroklos S."
-
1
Prospective Clinical Study of a Novel Left Atrial Appendage Occlusion Device
Published in The Annals of thoracic surgery (01-06-2012)“…Purpose This Food and Drug Administration–approved investigational device exempt trial assessed the safety and efficacy of a novel device for external left…”
Get full text
Journal Article -
2
Reducing the Effects of the Systemic Inflammatory Response to Cardiopulmonary Bypass: Can Single Dose Steroids Blunt Systemic Inflammatory Response Syndrome?
Published in ASAIO journal (1992) (01-03-2008)“…The use of cardiopulmonary bypass (CPB) is associated with the development of a significant systemic inflammatory response syndrome (SIRS) which can affect…”
Get full text
Journal Article -
3
Minimally invasive mitral valve repair using the da Vinci robotic system
Published in The Annals of thoracic surgery (01-06-2004)“…Minimally invasive mitral valve repair with a shortened hospital stay and quick return to an active lifestyle is the ultimate goal for robotically assisted…”
Get full text
Journal Article -
4
HeartWare miniature axial-flow ventricular assist device: design and initial feasibility test
Published in Texas Heart Institute journal (2009)“…Pulsatile ventricular assist devices have successfully provided circulatory support for many patients throughout the past quarter century; however, persistent…”
Get full text
Journal Article -
5
Platelet activation in heart failure patients supported by the HeartMate II ventricular assist device
Published in International journal of artificial organs (01-06-2011)“…Thromboembolic events have been observed in heart failure (HF) patients supported by long-term mechanical circulatory support (MCS) devices. It has been…”
Get full text
Journal Article -
6
A new method of monitoring recovery and weaning the thoratec left ventricular assist device
Published in The Annals of thoracic surgery (2001)“…Background. Recent scientific and clinical data suggest that chronic mechanical ventricular unloading may lead to myocardial recovery. Evaluating and…”
Get full text
Journal Article -
7
Prospective study on cardiopulmonary bypass prime reduction and its effect on intraoperative blood product and hemoconcentrator use
Published in Perfusion (01-01-2005)“…Purpose: Evaluate the feasibility and clinical significance of crystalloid prime reduction during the initiation of cardiopulmonary bypass (CPB) using a…”
Get full text
Journal Article -
8
Embol-X intra-aortic filtration system: capturing particulate emboli in the cardiac surgery patient
Published in The Journal of extra-corporeal technology (01-06-2005)“…We sought to evaluate the effectiveness of using an intra-aortic filtration system for the prevention of particulate emboli transport and the minimization of…”
Get full text
Journal Article -
9
Device Exchange to HeartMate 3 LVAD: Impact of Previous Pump Model on Clinical Outcomes
Published in Annals of thoracic surgery short reports (01-09-2023)“…We describe our clinical experience performing device exchange from a HeartMate II (HM2) or HVAD to a HeartMate 3 (HM3) left ventricular assist device. A…”
Get full text
Journal Article -
10
Peripheral cardiopulmonary bypass with modified assisted venous drainage and transthoracic aortic crossclamp: optimal management for robotic mitral valve repair
Published in Perfusion (01-09-2003)“…The purpose of this study was to evaluate peripheral cardiopulmonary bypass (CPB) with modified assisted venous drainage (MAVD) and transthoracic aortic…”
Get full text
Journal Article -
11
A Challenging Case: Durable Biventricular Assist Device, Bleeding, Thrombosis, and a Hole
Published in Journal of cardiac failure (01-08-2019)“…Cardiogenic shock requiring mechanical circulatory support as a bridge to recovery continues to pose challenges. For patients who are unable to be weaned off…”
Get full text
Journal Article -
12
An unusual case of hypoxia from benzocaine-induced methemoglobinemia
Published in The Annals of thoracic surgery (01-06-1999)“…Hypoxemia during bronchoscopy occurs frequently. It can usually be managed by supplemental oxygen and bronchodilators or, in some cases, occasionally stopping…”
Get full text
Journal Article Conference Proceeding -
13
Modified Minimally Invasive Technique for Greater Saphenous Vein Harvesting
Published in The Annals of thoracic surgery (01-02-1998)“…A technique is described for minimally invasive harvesting of the greater saphenous vein. This technique requires no new or disposable equipment, thus adding…”
Get full text
Journal Article -
14
Adverse outcomes in nontrial like patients on commercial HeartMate 3 LVAD support
Published in JHLT open (01-12-2023)Get full text
Journal Article -
15
Adverse outcomes in nontrial like patients on commercial HeartMate 3 LVAD support
Published in JHLT Open (01-12-2023)“…Background: Patient selection for real-world use of HeartMate 3 left ventricular assist device (HM3 LVAD) differs from that of clinical trials. We assessed…”
Get full text
Journal Article -
16
A new method of monitoring recovery and weaning the thoratec left ventricular assist device. Commentary
Published in The Annals of thoracic surgery (2001)Get full text
Journal Article -
17
HOME DISCHARGE EXPERIENCE WITH THE THORATEC LVAD TLC-II PORTABLE DRIVER
Published in ASAIO journal (1992) (01-03-2002)Get full text
Journal Article -
18
NEUROLOGIC AND BLEEDING COMPLICATIONS ASSOCIATED WITH THORATEC VENTRICULAR ASSIST DEVICE
Published in ASAIO journal (1992) (01-03-2002)Get full text
Journal Article -
19
SKINNED MYOCYTE FUNCTION AND ATP USE IN PATIENTS WITH LV DYSFUNCTION: PREDICTOR OF RECOVERY?
Published in ASAIO journal (1992) (01-03-2002)Get full text
Journal Article -
20
Minimally invasive mitral valve repair using the da Vinci robotic system. Discussion
Published in The Annals of thoracic surgery (2004)Get full text
Conference Proceeding