Search Results - "Panther, Jared G."
-
1
Speciation of Dissolved Inorganic Arsenic by Diffusive Gradients in Thin Films: Selective Binding of AsIII by 3-Mercaptopropyl-Functionalized Silica Gel
Published in Analytical chemistry (Washington) (01-11-2011)“…A diffusive gradients in thin films (DGT) technique for selectively measuring AsIII utilizes commercially available 3-mercaptopropyl-functionalized silica gel…”
Get full text
Journal Article -
2
Titanium dioxide-based DGT for measuring dissolved As(V), V(V), Sb(V), Mo(VI) and W(VI) in water
Published in Talanta (Oxford) (15-02-2013)“…A titanium dioxide-based DGT method (Metsorb-DGT) was evaluated for the measurement of As(V), V(V), Sb(V), Mo(VI), W(VI) and dissolved reactive phosphorus…”
Get full text
Journal Article -
3
DGT Measurement of Dissolved Aluminum Species in Waters: Comparing Chelex-100 and Titanium Dioxide-Based Adsorbents
Published in Environmental science & technology (21-02-2012)“…Aluminum is acutely toxic, and elevated concentrations of dissolved Al can have detrimental effects on both terrestrial and aquatic ecosystems. Robust…”
Get full text
Journal Article -
4
Evaluation of the Chelex-DGT technique for the measurement of rare earth elements in the porewater of estuarine and arine sediments
Published in Talanta (Oxford) (01-08-2021)“…This study describes the validation of a diffusive gradients in thin film (DGT) technique for determining lanthanide rare earth elements (REEs) and in situ…”
Get full text
Journal Article -
5
Simultaneous Measurement of Trace Metal and Oxyanion Concentrations in Water using Diffusive Gradients in Thin Films with a Chelex–Metsorb Mixed Binding Layer
Published in Analytical chemistry (Washington) (07-01-2014)“…A new diffusive gradients in thin films (DGT) technique with a mixed binding layer (Chelex-100 and the titanium dioxide based adsorbent Metsorb) is described…”
Get full text
Journal Article -
6
Titanium Dioxide-Based DGT Technique for In Situ Measurement of Dissolved Reactive Phosphorus in Fresh and Marine Waters
Published in Environmental science & technology (15-12-2010)“…A new diffusive gradients in a thin film (DGT) technique for measuring dissolved reactive phosphorus (DRP) in fresh and marine waters is reported. The new…”
Get full text
Journal Article -
7
New Diffusive Gradients in a Thin Film Technique for Measuring Inorganic Arsenic and Selenium(IV) Using a Titanium Dioxide Based Adsorbent
Published in Analytical chemistry (Washington) (01-09-2010)“…A new diffusive gradients in a thin film (DGT) technique, using a titanium dioxide based adsorbent (Metsorb), has been developed and evaluated for the…”
Get full text
Journal Article -
8
Investigating Arsenic Speciation and Mobilization in Sediments with DGT and DET: A Mesocosm Evaluation of Oxic-Anoxic Transitions
Published in Environmental science & technology (03-04-2012)“…Mobilization of arsenic from freshwater and estuarine sediments during the transition from oxic to anoxic conditions was investigated using recently developed…”
Get full text
Journal Article -
9
A colorimetric DET technique for the high-resolution measurement of two-dimensional alkalinity distributions in sediment porewaters
Published in Chemosphere (Oxford) (01-01-2015)“…•Method to measure high-resolution, 2D porewater alkalinity is presented.•Deployment in coastal sediment revealed heterogeneous alkalinity…”
Get full text
Journal Article -
10
Comparing dissolved reactive phosphorus measured by DGT with ferrihydrite and titanium dioxide adsorbents: Anionic interferences, adsorbent capacity and deployment time
Published in Analytica chimica acta (18-07-2011)“…The accuracy of the DGT technique for the measurement of DRP in natural waters is dependent on the adsorbent, adsorbent capacity and deployment time. [Display…”
Get full text
Journal Article -
11
Development and application of the diffusive gradients in thin films technique for the measurement of total dissolved inorganic arsenic in waters
Published in Analytica chimica acta (01-08-2008)“…The diffusive gradients in thin films (DGT) technique, utilizing an iron-hydroxide adsorbent, has been investigated for the in situ accumulation of total…”
Get full text
Journal Article -
12
Diurnal shifts in co-distributions of sulfide and iron(II) and profiles of phosphate and ammonium in the rhizosphere of Zostera capricorni
Published in Estuarine, coastal and shelf science (10-12-2012)“…High resolution, two dimensional distributions of porewater iron(II) and sulfide were measured, using colourimetric DET (diffusive equilibration in a thin…”
Get full text
Journal Article -
13
Evaluation of a titanium dioxide-based DGT technique for measuring inorganic uranium species in fresh and marine waters
Published in Talanta (Oxford) (15-08-2012)“…A new diffusive gradients in a thin film (DGT) technique for measuring dissolved uranium (U) in freshwater is reported. The new method utilises a previously…”
Get full text
Journal Article -
14
Optimization of colorimetric DET technique for the in situ, two-dimensional measurement of iron(II) distributions in sediment porewaters
Published in Talanta (Oxford) (15-01-2012)“…► An optimized DET method for measuring iron(II) in sediment porewaters is reported. ► Colorimetric analysis allows 2D distributions to be represented at 1mm2…”
Get full text
Journal Article -
15
Perfluorosulfonated Ionomer-Modified Diffusive Gradients in Thin Films: Tool for Inorganic Arsenic Speciation Analysis
Published in Analytical chemistry (Washington) (15-12-2008)“…A new concept in speciation analysis based on the diffusive gradients in thin films (DGT) technique is described. By use of two sets of DGT devices, one set…”
Get full text
Journal Article -
16
Micro/nanostructured MgO hollow spheres with selective adsorption performance and their application for fluoride monitoring in water
Published in Separation and purification technology (15-10-2022)“…•A micro/nanostructured porous MgO hollow sphere was prepared by a hydrothermal and subsequent annealing process.•The MgO exhibits selectively high adsorption…”
Get full text
Journal Article -
17
Evaluation of the Chelex-DGT technique for the measurement of rare earth elements in the porewater of estuarine and marine sediments
Published in Talanta (Oxford) (01-08-2021)“…This study describes the validation of a diffusive gradients in thin film (DGT) technique for determining lanthanide rare earth elements (REEs) and in situ…”
Get full text
Journal Article -
18
Micro/nanostructured porous ZnO as a new DGT binding phase for selective measurement of Cu(II) in water
Published in Colloids and surfaces. A, Physicochemical and engineering aspects (20-01-2018)“…[Display omitted] Micro/nanostructured porous ZnO was first utilized as a new binding phase in DGT (diffusive gradients in thin film) devices for selective…”
Get full text
Journal Article -
19
Development and application of diffusive gradients in thin films for determining inorganic arsenic concentrations in natural waters
Published in Acta geochimica (01-03-2006)Get full text
Journal Article -
20