Search Results - "Panettieri, Vanessa"
-
1
Effects of synchrotron‐based X‐rays and gold nanoparticles on normal and cancer cell morphology and migration
Published in Journal of synchrotron radiation (01-03-2023)“…It has been shown lately that gold nanoparticles (AuNPs) and ionizing radiation (IR) have inhibitory effects on cancer cell migration while having promoting…”
Get full text
Journal Article -
2
Artificial Intelligence and the future of radiotherapy planning: The Australian radiation therapists prepare to be ready
Published in Journal of medical radiation sciences (01-06-2024)“…The use of artificial intelligence (AI) solutions is rapidly changing the way radiation therapy tasks, traditionally relying on human skills, are approached by…”
Get full text
Journal Article -
3
The impact of a prophylactic skin dressing on surface‐guided patient positioning in chest wall Radiation Therapy
Published in Journal of medical radiation sciences (01-06-2024)“…Introduction Surface‐guided radiation therapy (SGRT) has emerged as a powerful tool to improve patient setup accuracy in radiation therapy (RT). Combined with…”
Get full text
Journal Article -
4
Proton versus photon therapy for high-risk prostate cancer with dose escalation of dominant intraprostatic lesions: a preliminary planning study
Published in Frontiers in oncology (08-11-2023)“…Background and purpose This study aimed to investigate the feasibility of safe-dose escalation to dominant intraprostatic lesions (DILs) and assess the…”
Get full text
Journal Article -
5
Predictive modelling for late rectal and urinary toxicities after prostate radiotherapy using planned and delivered dose
Published in Frontiers in oncology (16-12-2022)“…Normal tissue complication probability (NTCP) parameters derived from traditional 3D plans may not be ideal in defining toxicity outcomes for modern…”
Get full text
Journal Article -
6
A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking
Published in Medical physics (Lancaster) (01-05-2016)“…Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is…”
Get full text
Journal Article -
7
Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion
Published in Radiation oncology (London, England) (14-11-2021)“…To determine the optimal volume of barium for oesophageal localisation on cone-beam CT (CBCT) for locally-advanced non-small cell lung cancers (NSCLC) and…”
Get full text
Journal Article -
8
MArkerless image Guidance using Intrafraction Kilovoltage x-ray imaging (MAGIK): study protocol for a phase I interventional study for lung cancer radiotherapy
Published in BMJ open (20-01-2022)“…IntroductionIn radiotherapy, tumour tracking leads the radiation beam to accurately target the tumour while it moves in a complex and unpredictable way due to…”
Get full text
Journal Article -
9
Total body irradiation in Australia and New Zealand: results of a practice survey
Published in Australasian physical & engineering sciences in medicine (01-09-2020)“…Total body irradiation (TBI) is an important treatment modality for the preparation of patients for bone marrow transplants. It is technically challenging and…”
Get full text
Journal Article -
10
Development of an automated radiotherapy dose accumulation workflow for locally advanced high‐risk prostate cancer – A technical report
Published in Journal of medical radiation sciences (01-06-2021)“…An automated dose accumulation and contour propagation workflow using daily cone beam computed tomography (CBCTs) images for prostate cases that require pelvic…”
Get full text
Journal Article -
11
Constituent Components of Out-of-Field Scatter Dose for 18-MV Intensity Modulated Radiation Therapy Versus 3-Dimensional Conformal Radiation Therapy: A Comparison With 6-MV and Implications for Carcinogenesis
Published in International journal of radiation oncology, biology, physics (01-11-2014)“…Purpose To characterize and compare the components of out-of-field dose for 18-MV intensity modulated radiation therapy (IMRT) versus 3-dimensional conformal…”
Get full text
Journal Article -
12
Predictors for late genitourinary toxicity in men receiving radiotherapy for high-risk prostate cancer using planned and accumulated dose
Published in Physics and imaging in radiation oncology (01-01-2023)“…•Accumulated Bladder dose was significantly higher at the intermediate-high dose region (V30-65 Gy) compared to bladder planned dose.•Accumulated bladder dose…”
Get full text
Journal Article -
13
Dose-volume analysis of planned versus accumulated dose as a predictor for late gastrointestinal toxicity in men receiving radiotherapy for high-risk prostate cancer
Published in Physics and imaging in radiation oncology (01-07-2022)“…•Interfractional variations in organs at risk were observed in prostate radiotherapy.•Rectal accumulated dose was significantly higher at the intermediate-high…”
Get full text
Journal Article -
14
Development of a multicentre automated model to reduce planning variability in radiotherapy of prostate cancer
Published in Physics and imaging in radiation oncology (01-07-2019)“…Inter-institutional studies highlighted correlation between consistent radiotherapy quality and improved overall patient survival. In treatment planning…”
Get full text
Journal Article -
15
External Validation of a Predictive Model of Urethral Strictures for Prostate Patients Treated With HDR Brachytherapy Boost
Published in Frontiers in oncology (11-06-2020)“…Purpose: For prostate cancer treatment, comparable or superior biochemical control was reported when using External-Beam-Radiotherapy (EBRT) with…”
Get full text
Journal Article -
16
Identification of Catheter Displacements in HDR Prostate Brachytherapy Using a ‘Shift Image’ Reconstruction Technique
Published in Brachytherapy (01-05-2017)Get full text
Journal Article -
17
Contrast enhanced oesophageal avoidance for stereotactic body radiotherapy: Barium vs. Gastrografin
Published in Technical innovations & patient support in radiation oncology (01-12-2019)“…•Barium and Gastrografin improve oesophageal localisation on CBCT.•Barium allows more precise visualization of the oesophagus than Gastrografin.•Barium induced…”
Get full text
Journal Article -
18
Treatment Delivery Error Trapping in HDR Brachytherapy
Published in Brachytherapy (01-05-2016)Get full text
Journal Article -
19
Clinical Application of Pre-Treatment Image Verification of Catheter Positions for HDR Prostate Brachytherapy
Published in Brachytherapy (01-05-2017)Get full text
Journal Article -
20
Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer
Published in International journal of radiation oncology, biology, physics (01-04-2014)“…Purpose Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469)…”
Get full text
Journal Article