Search Results - "Panayiotakis, George"

Refine Results
  1. 1

    Applications of Generative Adversarial Networks (GANs) in Positron Emission Tomography (PET) imaging: A review by Apostolopoulos, Ioannis D., Papathanasiou, Nikolaos D., Apostolopoulos, Dimitris J., Panayiotakis, George S.

    “…Purpose This paper reviews recent applications of Generative Adversarial Networks (GANs) in Positron Emission Tomography (PET) imaging. Recent advances in Deep…”
    Get full text
    Journal Article
  2. 2

    The ultrasonographic measurement of muscle thickness in sarcopenia. A prediction study by Barotsis, Nikolaos, Galata, Angeliki, Hadjiconstanti, Anastasia, Panayiotakis, George

    “…Sarcopenia is a common disease in the elderly. Although extensive research has been conducted on muscle mass and quality assessment tools, there are still…”
    Get full text
    Journal Article
  3. 3

    Automatic Extraction of Muscle Parameters with Attention UNet in Ultrasonography by Katakis, Sofoklis, Barotsis, Nikolaos, Kakotaritis, Alexandros, Economou, George, Panagiotopoulos, Elias, Panayiotakis, George

    Published in Sensors (Basel, Switzerland) (13-07-2022)
    “…Automatically delineating the deep and superficial aponeurosis of the skeletal muscles from ultrasound images is important in many aspects of the clinical…”
    Get full text
    Journal Article
  4. 4

    MTF of columnar phosphors with a homogenous part: an analytical approach by Psichis, Konstantinos, Kalyvas, Nektarios, Kandarakis, Ioannis, Panayiotakis, George

    “…A method for the theoretical estimation of the MTF of columnar phosphors with a homogeneous part at the end used in X-ray imaging has been developed. This…”
    Get full text
    Journal Article
  5. 5

    PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS by Metaxas, Vasileios I, Messaris, Gerasimos A, Lekatou, Aristea N, Petsas, Theodore G, Panayiotakis, George S

    Published in Radiation protection dosimetry (01-07-2019)
    “…A local survey was conducted, to evaluate the radiation dose to adult patients who underwent diagnostic X-ray examinations. Patient-related and technical data…”
    Get full text
    Journal Article
  6. 6

    Reliability of muscle thickness measurements in ultrasonography by Barotsis, Nikolaos, Tsiganos, Panagiotis, Kokkalis, Zinon, Panayiotakis, George, Panagiotopoulos, Elias

    “…This study aims to clarify some of the issues associated with the reliable measurement of muscle thickness on ultrasonographic images of the musculoskeletal…”
    Get full text
    Journal Article
  7. 7

    Multi-input deep learning approach for Cardiovascular Disease diagnosis using Myocardial Perfusion Imaging and clinical data by Apostolopoulos, Ioannis D., Apostolopoulos, Dimitris I., Spyridonidis, Trifon I., Papathanasiou, Nikolaos D., Panayiotakis, George S.

    Published in Physica medica (01-04-2021)
    “…[Display omitted] •Multi input data classification methodology for Coronary Artery Disease diagnosis.•Integration of InceptionV3 network and Random Forest…”
    Get full text
    Journal Article
  8. 8

    Patient dose in CT angiography examinations: An institutional survey by Metaxas, Vasileios I., Dimitroukas, Christos P., Efthymiou, Fotios O., Zampakis, Petros E., Panayiotakis, George S., Kalogeropoulou, Christina P.

    “…This study aims to evaluate the radiation dose during five computed tomography angiography (CTA) examinations performed with a GE Light Speed 16 (16-slice) and…”
    Get full text
    Journal Article
  9. 9

    Explainable Artificial Intelligence Method (ParaNet+) Localises Abnormal Parathyroid Glands in Scintigraphic Scans of Patients with Primary Hyperparathyroidism by Apostolopoulos, Dimitris J, Apostolopoulos, Ioannis D, Papathanasiou, Nikolaos D, Spyridonidis, Trifon, Panayiotakis, George S

    Published in Algorithms (01-09-2023)
    “…The pre-operative localisation of abnormal parathyroid glands (PG) in parathyroid scintigraphy is essential for suggesting treatment and assisting surgery…”
    Get full text
    Journal Article
  10. 10

    Detection and Localisation of Abnormal Parathyroid Glands: An Explainable Deep Learning Approach by Apostolopoulos, Dimitris J, Apostolopoulos, Ioannis D, Papathanasiou, Nikolaos D, Spyridonidis, Trifon, Panayiotakis, George S

    Published in Algorithms (01-12-2022)
    “…Parathyroid scintigraphy with 99mTc-sestamibi (MIBI) is an established technique for localising abnormal parathyroid glands (PGs). However, the identification…”
    Get full text
    Journal Article
  11. 11

    LOW BMI PATIENT DOSE IN DIGITAL RADIOGRAPHY by Efthymiou, Fotios O, Metaxas, Vasileios I, Dimitroukas, Christos P, Panayiotakis, George S

    Published in Radiation protection dosimetry (07-07-2020)
    “…Abstract In this study, the radiation dose received by 364 low body mass index (BMI) adult patients undergoing chest, abdomen, lumbar spine, kidneys and…”
    Get full text
    Journal Article
  12. 12

    Automatic classification of solitary pulmonary nodules in PET/CT imaging employing transfer learning techniques by Apostolopoulos, Ioannis D., Pintelas, Emmanuel G., Livieris, Ioannis E., Apostolopoulos, Dimitris J., Papathanasiou, Nikolaos D., Pintelas, Panagiotis E., Panayiotakis, George S.

    “…Early and automatic diagnosis of Solitary Pulmonary Nodules (SPN) in Computed Tomography (CT) chest scans can provide early treatment for patients with lung…”
    Get full text
    Journal Article
  13. 13

    Patient dose audit in common CT examinations by Dimitroukas, Christos P., Metaxas, Vasileios I., Efthymiou, Fotios O., Kalogeropoulou, Christina P., Zampakis, Petros E., Panayiotakis, George S.

    “…A dose audit was performed to evaluate the radiation dose to 573 adult patients, who underwent eleven common CT examinations in two different CT scanners: one…”
    Get full text
    Journal Article
  14. 14

    PATIENT DOSE IN DIGITAL RADIOGRAPHY UTILISING BMI CLASSIFICATION by Metaxas, Vasileios I, Messaris, Gerasimos A, Lekatou, Aristea N, Petsas, Theodore G, Panayiotakis, George S

    Published in Radiation protection dosimetry (01-08-2019)
    “…Dose audit is important towards optimisation of patients' radiation protection in diagnostic radiography. In this study, the effect of the body mass index…”
    Get full text
    Journal Article
  15. 15

    DOSIMETRIC EVALUATION OF THE TWO-PHASE COMPUTED TOMOGRAPHY IN PARATHYROID GLANDS IMAGING by Dimitroukas, Christos P, Metaxas, Vasileios I, Efthymiou, Fotios O, Zampakis, Petros E, Kalogeropoulou, Christina P, Panayiotakis, George S

    Published in Radiation protection dosimetry (12-11-2021)
    “…Abstract This study evaluates the patient radiation dose from the two-phase protocols of two different computed tomography (CT) systems and compares this with…”
    Get full text
    Journal Article
  16. 16

    Patient Dose Estimation in Computed Tomography-Guided Biopsy Procedures by Siomou, Evangelia, Filippiadis, Dimitrios K, Efstathopoulos, Efstathios P, Antonakos, Ioannis, Panayiotakis, George S

    Published in Journal of imaging (30-11-2023)
    “…This study establishes typical Diagnostic Reference Levels (DRL) values and assesses patient doses in computed tomography (CT)-guided biopsy procedures. The…”
    Get full text
    Journal Article
  17. 17

    Luminescence Efficiency of Cadmium Tungstate (CdWO4) Single Crystal for Medical Imaging Applications by Michail, Christos, Koukou, Vaia, Martini, Niki, Saatsakis, George, Kalyvas, Nektarios, Bakas, Athanasios, Kandarakis, Ioannis, Fountos, George, Panayiotakis, George, Valais, Ioannis

    Published in Crystals (Basel) (01-06-2020)
    “…Background: In this study, the light output of a cadmium tungstate (CdWO4) single crystal was measured under various X-ray radiographic energies. Methods: A…”
    Get full text
    Journal Article
  18. 18

    Muscle Cross-Sectional Area Segmentation in Transverse Ultrasound Images Using Vision Transformers by Katakis, Sofoklis, Barotsis, Nikolaos, Kakotaritis, Alexandros, Tsiganos, Panagiotis, Economou, George, Panagiotopoulos, Elias, Panayiotakis, George

    Published in Diagnostics (Basel) (06-01-2023)
    “…Automatically measuring a muscle’s cross-sectional area is an important application in clinical practice that has been studied extensively in recent years for…”
    Get full text
    Journal Article
  19. 19

    PATIENT SIZE INDICES AND DOSE IN FLUOROSCOPICALLY GUIDED LUMBAR DISCECTOMY AND FUSION: A PRELIMINARY STUDY by Metaxas, Vasileios I, Gatzounis, George D, Tzortzidis, Fotios N, Panayiotakis, George S

    Published in Radiation protection dosimetry (30-12-2020)
    “…Abstract Patient dose values varied significantly during interventional procedures, mainly due to the patient size, operators’ choices and clinical complexity…”
    Get full text
    Journal Article
  20. 20

    BMI-Based organ doses in endovascular aneurysm repair interventions utilising Monte Carlo simulation by Efthymiou, Fotios O., Metaxas, Vasileios I., Dimitroukas, Christos P., Kakkos, Stavros K., Moulakakis, Konstantinos G., Belavgenis, Andreas C., Panayiotakis, George S.

    Published in Applied radiation and isotopes (01-05-2023)
    “…In this study, the effect of body-mass-index (BMI) on organ doses (ODs) during infrarenal endovascular-aneurysm-repair (EVAR) procedures was evaluated…”
    Get full text
    Journal Article