Search Results - "Paltauf, Guenther"
-
1
Photoacoustic tomography reveals structural and functional cardiac images of animal models
Published in Light, science & applications (13-02-2023)“…Three-dimensional photoacoustic tomography synchronized with an electrocardiogram provides highly resolved images of a beating heart with optical absorption…”
Get full text
Journal Article -
2
Laser ultrasound wave pattern analysis for efficient defect detection in samples with curved surfaces
Published in Photoacoustics (Munich) (01-12-2024)“…Many production processes involve curved sample surfaces, such as welding or additive manufacturing. These pose new challenges to characterization methods for…”
Get full text
Journal Article -
3
Piezoelectric line detector array for photoacoustic tomography
Published in Photoacoustics (Munich) (01-12-2017)“…Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate…”
Get full text
Journal Article -
4
Efficient testing of weld seam models with radii of curvature in the millimeter range using laser ultrasound
Published in Ultrasonics (01-04-2024)“…Laser ultrasound is a widely used tool for industrial quality assurance when a contactless and fast method is required. In this work, we used a laboratory…”
Get full text
Journal Article -
5
Photoacoustic computational ghost imaging
Published in Optics letters (15-03-2022)“…Photoacoustic imaging with optical resolution usually requires a single-pixel raster scan. An alternative approach based on illumination with patterns obtained…”
Get more information
Journal Article -
6
High resolution three-dimensional photoacoutic tomography with CCD-camera based ultrasound detection
Published in Biomedical optics express (01-08-2014)“…A photoacoustic tomograph based on optical ultrasound detection is demonstrated, which is capable of high resolution real-time projection imaging and fast…”
Get full text
Journal Article -
7
Artifact removal in photoacoustic section imaging by combining an integrating cylindrical detector with model-based reconstruction
Published in Journal of biomedical optics (01-02-2014)“…Photoacoustic section imaging reveals optically absorbing structures within a thin slice of an object. It requires measuring acoustic waves excited by…”
Get full text
Journal Article -
8
Modeling photoacoustic imaging with a scanning focused detector using Monte Carlo simulation of energy deposition
Published in Journal of biomedical optics (01-12-2018)“…Photoacoustic imaging using a focused, scanning detector in combination with a pulsed light source is a common technique to visualize light-absorbing…”
Get full text
Journal Article -
9
Combined photoacoustic, pulse-echo laser ultrasound, and speed-of-sound imaging using integrating optical detection
Published in Journal of biomedical optics (01-08-2016)“…A purely optical setup for the coregistration of photoacoustic (PA), ultrasound (US), and speed-of-sound (SOS) section images is presented. It extends a…”
Get full text
Journal Article -
10
Femtosecond-laser-induced nanocavitation in water: implications for optical breakdown threshold and cell surgery
Published in Physical review letters (25-01-2008)“…We determined the bubble radius R_(max) for femtosecond optical breakdown in water at 347, 520, and 1040 nm with an unprecedented accuracy (+/-10 nm). At…”
Get full text
Journal Article -
11
Stealth ryanodine-sensitive Ca2+ release contributes to activity of capacitative Ca2+ entry and nitric oxide synthase in bovine endothelial cells
Published in The Journal of physiology (01-12-1998)“…The involvement of ryanodine-sensitive Ca 2+ release (RsCR) in bradykinin (Bk)-induced Ca 2+ release, capacitative Ca 2+ entry (CCE) and nitric oxide synthase…”
Get full text
Journal Article -
12
Conical ring array detector for large depth of field photoacoustic macroscopy
Published in Biomedical optics express (01-05-2020)“…Photoacoustic microscopy and macroscopy (PAM) using focused detector scanning are emerging imaging methods for biological tissue, providing high resolution and…”
Get full text
Journal Article -
13
Full field detection in photoacoustic tomography
Published in Optics express (15-03-2010)“…Imaging the full acoustic field around an object by use of an optical phase contrast method is used to accelerate the data acquisition in photoacoustic…”
Get full text
Journal Article -
14
Comparison of Piezoelectric and Optical Projection Imaging for Three-Dimensional In Vivo Photoacoustic Tomography
Published in Journal of imaging (11-01-2019)“…Ultrasound sensor arrays for photoacoustic tomography (PAT) are investigated that create line projections of the pressure generated in an object by pulsed…”
Get full text
Journal Article -
15
Photoacoustic section imaging with an integrating cylindrical detector
Published in Biomedical optics express (01-11-2011)“…A piezoelectric detector with a cylindrical shape is investigated for photoacoustic section imaging. Images are acquired by rotating a sample in front of the…”
Get full text
Journal Article -
16
Hybrid photoacoustic and ultrasound section imaging with optical ultrasound detection
Published in Journal of biophotonics (01-06-2013)“…A setup is proposed that provides perfectly co‐registered photoacoustic (PA) and ultrasound (US) section images. Photoacoustic and ultrasound backscatter…”
Get full text
Journal Article -
17
Deblurring algorithms accounting for the finite detector size in photoacoustic tomography
Published in Journal of biomedical optics (01-05-2014)“…Most reconstruction algorithms for photoacoustic tomography, like back projection or time reversal, work ideally for point-like detectors. For real detectors,…”
Get full text
Journal Article -
18
High resolution three-dimensional photoacoustic tomography with CCD-camera based ultrasound detection
Published in Biomedical optics express (01-08-2014)Get full text
Journal Article -
19
Simultaneous three-dimensional photoacoustic and laser-ultrasound tomography
Published in Biomedical optics express (2013)“…A tomographic setup that provides the co-registration of photoacoustic (PA) and ultrasound (US) images is presented. For pulse-echo US-tomography laser-induced…”
Get full text
Journal Article -
20
Downstream Fabry-Perot interferometer for acoustic wave monitoring in photoacoustic tomography
Published in Optics letters (15-03-2011)“…An optical detection setup consisting of a focused laser beam fed into a downstream Fabry-Perot interferometer (FPI) for demodulation of acoustically generated…”
Get more information
Journal Article