Search Results - "PHILIPP, M. O"

  • Showing 1 - 15 results of 15
Refine Results
  1. 1

    Radiological emergency room management with emphasis on multidetector-row CT by Philipp, M.O., Kubin, K., Hörmann, M., Metz, V.M.

    Published in European journal of radiology (01-10-2003)
    “…Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The…”
    Get full text
    Journal Article
  2. 2

    Predictors of long-term results after treatment of iliac artery obliteration by transluminal angioplasty and stent deployment by FUNOVICS, M. A, LACKNER, B, CEJNA, M, PELOSCHEK, P, SAILER, J, PHILIPP, M. O, MACA, T, AHMADI, A, MINAR, E, LAMMER, J

    “…To investigate initial and long-term success rate after percutaneous treatment of iliac artery occlusion with angioplasty and stent deployment. To investigate…”
    Get full text
    Journal Article
  3. 3

    Feasibility Study of NeoMend, a Percutaneous Arterial Closure Device That Uses a Nonthrombogenic Bioadhesive by Funovics, M. A, Wolf, F, Philipp, M. O, Kee, S, Tichy, B, Dirisamer, A, Rand, T, Lammer, J

    Published in American journal of roentgenology (1976) (01-02-2003)
    “…The aim of this prospective single-center phase I feasibility study was to investigate the safety and efficacy of a novel vascular sealing device, the NeoMend…”
    Get full text
    Journal Article
  4. 4

    Galactography: method of choice in pathologic nipple discharge? by Funovics, M A, Philipp, M O, Lackner, B, Fuchsjaeger, M, Funovics, P T, Metz, V

    Published in European radiology (01-01-2003)
    “…Our objective was to assess the role of galactography in the diagnostic work-up of patients with pathological nipple discharge together with exfoliative…”
    Get full text
    Journal Article
  5. 5

    Role of doppler sonography in the evaluation of accessory spleens after splenectomy by Herneth, A. M, Pokieser, P, Philipp, M. O, Bader, T. R, Helbich, T. H, Mallek, R, Mostbeck, G. H

    Published in Journal of ultrasound in medicine (01-12-2001)
    “…Splenectomy influences the Doppler blood flow pattern in the splenic artery. Blood flow in this vessel might return to normal if an accessory spleen increases…”
    Get full text
    Journal Article
  6. 6

    Acute osseous traumatic lesions of the shoulder girdle by Philipp, M O, Philipp-Hauser, S, Gäbler, C, Breitenseher, M

    Published in Radiologe (01-06-2004)
    “…Traumatic injuries to the shoulder girdle are common lesions and occur from birth on through the whole life. Depending on the patient's age, localization and…”
    Get full text
    Journal Article
  7. 7
  8. 8

    Vertebral metastases: assessment with apparent diffusion coefficient by Herneth, Andreas M, Philipp, Marcel O, Naude, Jonathan, Funovics, Martin, Beichel, Reinhard R, Bammer, Roland, Imhof, Herwig

    Published in Radiology (01-12-2002)
    “…The authors evaluated the apparent diffusion coefficient (ADC) in the assessment of vertebral metastases and acute vertebral compression fractures in 22…”
    Get more information
    Journal Article
  9. 9

    Imaging of the scrotum in children by Hörmann, Marcus, Balassy, Csilla, Philipp, Marcel O, Pumberger, Wolfgang

    Published in European radiology (01-06-2004)
    “…Clinical examination of the scrotum is difficult due to the small size of the testes and the epididymis in infants and young children, and eliciting patients'…”
    Get full text
    Journal Article
  10. 10

    Asymmetric Closure of Ischiopubic Synchondrosis in Pediatric Patients: Correlation with Foot Dominance by Herneth, Andreas M, Philipp, Marcel O, Pretterklieber, Michael L, Balassy, Csilla, Winkelbauer, Friedrich W, Beaulieu, Christopher F

    Published in American journal of roentgenology (1976) (01-02-2004)
    “…The enlarged ischiopubic synchondrosis is a well-known anatomic structure; however, little is known about its physiology. In early childhood, enlargement of…”
    Get full text
    Journal Article
  11. 11

    Three-dimensional volume rendering of multidetector-row CT data: applicable for emergency radiology by Philipp, Marcel O., Kubin, Klaus, Mang, Thomas, Hörmann, Marcus, Metz, Viktor M.

    Published in European journal of radiology (01-10-2003)
    “…Multidetector-row computed tomography (MD-CT) not only creates new opportunities but also challenges for medical imaging. Isotropic imaging allows in-depth…”
    Get full text
    Journal Article
  12. 12

    Four-Channel Multidetector CT in Facial Fractures: Do We Need 2 x 0.5 mm Collimation? by Philipp, Marcel O, Funovics, Martin A, Mann, Frederick A, Herneth, Andreas M, Fuchsjaeger, Michael H, Grabenwoeger, Florian, Lechner, Gerhard, Metz, Viktor M

    Published in American journal of roentgenology (1976) (01-06-2003)
    “…Our aim was to optimize acquisition protocols and multiplanar reformation algorithms for the evaluation of facial fractures using multidetector CT (MDCT) and…”
    Get full text
    Journal Article
  13. 13

    The effect of varying low-dose protocols on perceived image quality in multidetector CT in a rabbit model of acute appendicitis by Hörmann, Marcus, Philipp, Marcel O, Eberl, Heidrun, Windberger, Ursula, Matzek, Wolfgang, Schäfer-Prokop, Cornelia, Metz, Viktor M

    Published in European radiology (01-08-2004)
    “…The aim of this study was to evaluate the value of multidetector CT (MD-CT) with low-dose protocols in the diagnosis of acute appendicitis in a rabbit model…”
    Get full text
    Journal Article
  14. 14

    Diagnostic management of nipple discharge by Fuchsjäger, Michael H, Philipp, Marcel O, Loewe, Christian, Helbich, Thomas H

    Published in Wiener Klinische Wochenschrift (2003)
    “…Nipple discharge may be a symptom of a variety of diseases. The importance of nipple discharge is its possible association with breast carcinoma. Not only the…”
    Get full text
    Journal Article
  15. 15