Search Results - "PAULTER, N. G"

Refine Results
  1. 1

    The Effect of Non-equispaced Sampling Instants, Sub-period Record Epochs, and Timebase Gain on the Information Content of Discretized Replicas of Periodic Signals by Paulter, Jr, N G

    “…The effect of non-equispaced sampling instants and timebase gain on the information content of the discretized replica of a periodic signal is examined. The…”
    Get full text
    Journal Article
  2. 2

    An assessment on the accuracy of time-domain reflectometry for measuring the characteristic impedance of transmission lines by Paulter, N.G.

    “…An assessment of time-domain reflectometry (TDR) for measuring the characteristic impedance Z/sub TL/ of transmission lines is performed. The assessment…”
    Get full text
    Journal Article
  3. 3

    Wide-Bandwidth Coaxial PWB Transmission Line Probe by Paulter, N. G., Palm, R. H., Barry, D. D.

    “…The design, fabrication, and test of a wide-bandwidth (3-dB attenuation bandwidth \geq 30 GHz), 50 \Omega , passive coaxial probe for the electrical…”
    Get full text
    Journal Article
  4. 4

    Sources of uncertainty in the nose-to-nose sampler calibration method by Paulter, N.G., Larson, D.R.

    “…We analyze the nose-to-nose (ntn) method for use as an accurate sampler calibration method. The variations in the measurement of the sampler impulse response…”
    Get full text
    Journal Article
  5. 5

    Long-term repeatability of a TDR-based printed wiring board dielectric constant measurement system by Paulter, N.G.

    “…A new time-domain-reflectometry-based method has been recently developed that provides accurate determinations of the dielectric constant of printed wiring…”
    Get full text
    Journal Article
  6. 6

    The "Median" Method for the Reduction of Noise and Trigger Jitter on Waveform Data by Paulter, N G, Larson, D R

    “…The "median" method for the reduction of the effect of noise and trigger jitter on waveform data is described. The effectiveness of this method was examined…”
    Get full text
    Journal Article
  7. 7

    NIST-NPL interlaboratory pulse measurement comparison by Paulter, N.G., Smith, A.J.A., Larson, D.R., Souders, T.M., Roddie, A.G.

    “…A comparison of the pulse parameter values obtained from the pulse measurement services of the National Institute of Standards and Technology, USA, and the…”
    Get full text
    Journal Article
  8. 8

    Low-jitter trigger system for pulse calibration and intercomparison of high-speed samplers by Paulter, N.G.

    “…A low-jitter (<1 ps) trigger system for pulse-waveform-based calibration and intercomparison of high-speed samplers is described. The system uses a…”
    Get full text
    Journal Article
  9. 9

    The effect of histogram size on histogram-derived pulse parameters by Paulter, N.G.

    “…The effects of the number of histogram bins on histogram-derived pulse parameters of step-like waveforms is examined. An empirical method for selecting the…”
    Get full text
    Journal Article
  10. 10

    Carrier lifetimes in ion-damaged GaAs by JOHNSON, M. B, MCGILL, T. C, PAULTER, N. G

    Published in Applied physics letters (12-06-1989)
    “…Photoluminescence excitation correlation spectroscopy has been used to measure the dependence of carrier lifetime on the H+ ion implantation dose in GaAs. For…”
    Get full text
    Journal Article
  11. 11

    The effects of offset voltage on the amplitude and bandwidth of kick-out pulses used in the nose-to-nose sampler impulse response characterization method by Larson, D.R., Paulter, N.G.

    “…The amplitude and bandwidth of kick-out pulses used in the nose-to-nose sampler impulse response characterization method were measured as a function of offset…”
    Get full text
    Journal Article
  12. 12

    High-speed optoelectronic pulse generation and sampling system by Paulter, N.G.

    “…A very-high-frequency (>100-GHz) optoelectronic pulsing and sampling system is presented. This system is used for the characterization of high-speed electronic…”
    Get full text
    Journal Article
  13. 13

    Uncertainty in the Nose-to-Nose Sampler Calibration Method Due to the Assertion That the Generator and Receiver Functions Are Identical by Paulter, N.G., Larson, D.R.

    “…The nose-to-nose (ntn) sampler calibration method can only be used for particular sampler structures; however, for such structures, it provides a technique for…”
    Get full text
    Journal Article
  14. 14

    Impedance of Transfer Standards Used in the Calibration of High-Speed Samplers and Pulse Generators by Paulter, N.G., Larson, D.R.

    “…The impedance of the calibration artifact or transfer standard (TS; pulse generator or sampler) is often ignored in high-speed pulse metrology. Using an air…”
    Get full text
    Journal Article
  15. 15

    Observed circuit limits to time resolution in correlation measurements with Si-on-sapphire, GaAs, and InP picosecond photoconductors by HAMMOND, R. B, PAULTER, N. G, WAGNER, R. S

    Published in Applied physics letters (01-08-1984)
    “…We report cross-correlation measurements of the response of photoconductor pulsers and sampling gates excited by a femtosecond laser. The photoconductors were…”
    Get full text
    Journal Article
  16. 16

    The IEEE standard on transitions, pulses, and related waveforms, Std-181-2003 by Paulter, N.G., Larson, D.R., Blair, J.J.

    “…The IEEE has written a new standard on pulse techniques and definitions to replace the withdrawn standards IEEE Std-181-1977 and Std-194-1977. The new…”
    Get full text
    Journal Article
  17. 17

    Pulse parameter dependence on transition occurrence instant and waveform epoch by Larson, D.R., Paulter, N.G., Bergman, D.I.

    “…The pulse parameters of amplitude and transition duration are dependent on the waveform epoch and transition occurrence instant of the pulse transition in the…”
    Get full text
    Journal Article
  18. 18

    Integrated picosecond photoconductors produced on bulk Si substrates by HAMMOND, R. B, PAULTER, N. G, WAGNER, R. S, EISENSTADT, W. R

    Published in Applied physics letters (15-08-1984)
    “…Optoelectronic cross-correlation measurements of the response of photoconductor pulsers and sampling gates formed on Si wafers are reported. These…”
    Get full text
    Journal Article
  19. 19

    An accurate method for measuring the dielectric constant of printed wiring board materials by Paulter, N.G.

    Published in Circuit world (01-03-2000)
    “…A new time-domain reflectometry measurement method is described that provides accurate measurements of the average high-frequency (0.1GHz - 10GHz) dielectric…”
    Get full text
    Journal Article
  20. 20

    A discussion of the IEEE standard on transition and pulse waveforms, Std-181-2003 by Paulter, N.G., Larson, D.R., Blair, Jerome J.

    “…The IEEE Std-181-2003, which is a new standard on pulse techniques and definitions, has been recently published. This standard was written to replace the…”
    Get full text
    Journal Article