Search Results - "Ossant, Frederic"
-
1
Microbubbles combined with ultrasound therapy in ischemic stroke: A systematic review of in-vivo preclinical studies
Published in PloS one (08-02-2018)“…Microbubbles (MBs) combined with ultrasound sonothrombolysis (STL) appears to be an alternative therapeutic strategy for acute ischemic stroke (IS), but…”
Get full text
Journal Article -
2
Inkjet-printed P(VDF-TrFE) film for high-frequency annular array
Published in IEEE transactions on ultrasonics, ferroelectrics, and frequency control (01-04-2023)“…An innovative processing to deposit P(VDF-TrFE) film on silicon wafers by an inkjet printing method was used to fabricate high-frequency annular array…”
Get full text
Journal Article -
3
High-Resolution Elastography for Thin-Layer Mechanical Characterization: Toward Skin Investigation
Published in Ultrasound in medicine & biology (01-03-2017)“…Abstract Interest in elasticity estimation for thin layers is increasing because of the various potential applications, including dermatology and cosmetology…”
Get full text
Journal Article -
4
3-D-Printed Phantom Fabricated by Photopolymer Jetting Technology for High-Frequency Ultrasound Imaging
Published in IEEE transactions on ultrasonics, ferroelectrics, and frequency control (01-06-2018)“…In the field of high-frequency ultrasound imaging (≥ 20 MHz), tools for characterizing the performance of imaging systems are lacking. Indeed, commercial…”
Get full text
Journal Article -
5
Skin anisotropy in vivo and initial natural stress effect: A quantitative study using high-frequency static elastography
Published in Journal of biomechanics (15-11-2012)“…Abstract Background Most studies on skin anisotropy are carried out in an “average” context, e.g. with an extension/compression test on the skin in vivo , the…”
Get full text
Journal Article -
6
Acoustic and Elastic Properties of a Blood Clot during Microbubble-Enhanced Sonothrombolysis: Hardening of the Clot with Inertial Cavitation
Published in Pharmaceutics (26-09-2021)“…Stroke is the second leading cause of death worldwide. Existing therapies present limitations, and other therapeutic alternatives are sought, such as…”
Get full text
Journal Article -
7
One-step surgical removal of cutaneous melanoma with surgical margins based on preoperative ultrasound measurement of the thickness of the melanoma
Published in EJD. European journal of dermatology (01-03-2018)“…Background Surgical margins of melanoma vary from 5 mm to 1 or 2 cm depending on histology thickness (Breslow). This approach usually requires two surgical…”
Get full text
Journal Article -
8
High-frequency ultrasound imaging for cutaneous neurofibroma in patients with neurofibromatosis type I
Published in EJD. European journal of dermatology (01-05-2017)“…Background Neurofibromas (NFs) are benign tumours arising from a nerve sheath, which are present in nearly all patients with neurofibromatosis type 1 (NF1)…”
Get full text
Journal Article -
9
Evaluation of high resolution ultrasound as a tool for assessing the 3D volume of blood clots during in vitro thrombolysis
Published in Scientific reports (24-07-2017)“…Thrombosis is a major cause of several diseases, i.e . myocardial infarction, cerebral stroke and pulmonary embolism. Thrombolytic therapies are required to…”
Get full text
Journal Article -
10
Axial Ultrasound B-Scans of the Entire Eye With a 20-MHz Linear Array: Correction of Crystalline Lens Phase Aberration by Applying Fermat's Principle
Published in IEEE transactions on medical imaging (01-11-2014)“…In ophthalmic ultrasonography the crystalline lens is known to be the main source of phase aberration, causing a significant decrease in resolution and…”
Get full text
Journal Article -
11
Low-Frequency Intrapulmonary Percussive Ventilation Increases Aerosol Penetration in a 2-Compartment Physical Model of Fibrotic Lung Disease
Published in Frontiers in bioengineering and biotechnology (28-08-2020)“…In patients with fibrotic pulmonary disease such as idiopathic pulmonary fibrosis (IPF), inhaled aerosols deposit mostly in the less affected region of the…”
Get full text
Journal Article -
12
High Frequency Ultrasound Device to Investigate the Acoustic Properties of Whole Blood During Coagulation
Published in Ultrasound in medicine & biology (01-02-2008)“…Abstract This study was designed to investigate the changes in acoustic properties of whole blood during the coagulation process. High frequency (from 20 to 40…”
Get full text
Journal Article -
13
Ultrasonic characterization of maturation of fetal lung microstructure: an animal study
Published in Ultrasound in medicine & biology (01-02-2001)“…Scattering parameters and histological properties of the ewe fetal lung microstructure were examined in vitro. Four groups of lamb fetuses were chosen at 80,…”
Get more information
Journal Article -
14
Mechanical skin thinning-to-thickening transition observed in vivo through 2D high frequency elastography
Published in Journal of biomechanics (16-11-2010)“…Abstract This study was based on two dimensional (2D) high frequency elastography to describe quantitatively the mechanical behavior of the human dermis in…”
Get full text
Journal Article -
15
High frequency ultrasound imaging of whole blood gelation and retraction during in vitro coagulation
Published in The Journal of the Acoustical Society of America (01-05-2012)“…Blood coagulation is a series of biochemical reactions resulting in the mechanical transformation of liquid blood into a gel. As a consequence, ultrasound,…”
Get full text
Journal Article -
16
Interest of the attenuation coefficient in multiparametric high frequency ultrasound investigation of whole blood coagulation process
Published in The Journal of the Acoustical Society of America (2009)“…Previous studies [R. Libgot, F. Ossant, Y. Gruel, P. Lermusiaux, and F. Patat, Proc.-IEEE Utrason. Symp. 4, 2259-2262 (2005); R. Libgot-Calle, F. Ossant, Y…”
Get full text
Journal Article -
17
Impact of exogenous stress on TGF-β inducible early gene 1 in human skin cells
Published in Experimental dermatology (01-11-2015)Get full text
Journal Article -
18
High-Frequency Transient Elastography Prototype to Assess Skin (Dermis) Fibrosis: A Diagnostic Study in Patients with Venous Insufficiency and Controls
Published in Ultraschall in der Medizin (01-10-2021)“…High-frequency transient elastography (HF-TE) is a noninvasive technique for assessing shear-wave speed and finally elasticity in thin tissue such as the skin…”
Get more information
Journal Article -
19
Evaluation of the Sensitivity of an in vitro High Frequency Ultrasound Device to Monitor the Coagulation Process: Study of the Effects of Heparin Treatment in a Murine Model
Published in Ultrasound in medicine & biology (01-02-2010)“…Abstract This study evaluates the sensitivity of a new in vitro high frequency ultrasound test of the whole blood coagulation process. A rat model of…”
Get full text
Journal Article -
20
Impact of Sonothrombolysis on in vitro Blood Clot: Pictographic Validation with Electron Microscopy
Published in Ultraschall in der Medizin (01-01-2017)Get more information
Journal Article