Search Results - "Olsen, R.G."
-
1
Application of a corona onset criterion to calculation of corona onset voltage of stranded conductors
Published in IEEE transactions on dielectrics and electrical insulation (01-08-2004)“…The conditions under which corona first occurs for any set of electrodes are an important design consideration since corona can limit the performance of any…”
Get full text
Journal Article -
2
The Utilization of Satellite Images to Identify Trees Endangering Transmission Lines
Published in IEEE transactions on power delivery (01-07-2009)“…This paper introduces an innovative concept for the use of multispectral stereo pair of satellite images to identify dangerous trees and plants along overhead…”
Get full text
Journal Article -
3
A new method for real-time monitoring of high-voltage transmission-line conductor sag
Published in IEEE transactions on power delivery (01-10-2002)“…The amount of power flowing through a high-voltage transmission line is proportional to its voltage and the current flowing through it. To increase power flow…”
Get full text
Journal Article -
4
Electromagnetic wave propagation on a thin wire above earth
Published in IEEE transactions on antennas and propagation (01-09-2000)“…The electromagnetic properties of a current on a thin horizontal wire above a flat lossy earth is reviewed. Attention is given to the historical development of…”
Get full text
Journal Article -
5
Corona onset as a design optimization criterion for high voltage hardware
Published in IEEE transactions on dielectrics and electrical insulation (01-12-2000)“…Hardware for use on HV systems is designed to be corona free. Recent hardware design activity has been centered around attempts to increase the corona onset…”
Get full text
Journal Article -
6
Interaction Between Power Frequency Electric Fields and RF Survey Meters: Test Protocol and Evaluation of Commercial Meters
Published in IEEE transactions on power delivery (01-10-2007)“…A radio-frequency (RF) survey meter is often used to evaluate the safety of human exposure to RF electromagnetic fields. However, erroneous meter indications…”
Get full text
Journal Article -
7
Corona Onset Voltage at 60 Hz and at High Frequency for an Isolated Cylindrical Monopole
Published in IEEE transactions on electromagnetic compatibility (01-08-2008)“…Corona on electrified conductors (power lines, transmission lines, and antennas) is a significant source of electromagnetic interference to aircraft. The…”
Get full text
Journal Article -
8
Use of Global Positioning System (GPS) receivers under power-line conductors
Published in IEEE transactions on power delivery (01-10-2002)“…The use of Global Positioning System (GPS) technology continues to grow and accuracy augmentations will generate ever more innovative applications. The issue…”
Get full text
Journal Article -
9
A simple hybrid method for ELF shielding by imperfect finite planar shields
Published in IEEE transactions on electromagnetic compatibility (01-05-2004)“…A simple method is described for calculating the shielding performance of a two-dimensional (2-D) thin finite-width shield made of imperfect material in the…”
Get full text
Journal Article -
10
The interaction between ELF electric fields and RF survey meters: theory and experiment
Published in IEEE transactions on electromagnetic compatibility (01-02-2005)“…An RF survey meter is often used to evaluate the safety of human exposure to RF electromagnetic fields. However, it has been noted that erroneous meter…”
Get full text
Journal Article -
11
On simple methods for calculating ELF shielding of infinite planar shields
Published in IEEE transactions on electromagnetic compatibility (01-08-2003)“…Simple approximate methods are developed and described for calculating the extremely low-frequency magnetic-shielding effectiveness for single- and…”
Get full text
Journal Article -
12
Closure on "A new method for real-time monitoring of high voltage transmission line conductor sag"
Published in IEEE transactions on power delivery (01-10-2003)“…The authors reply to the comments by Y Moltis (see ibid., vol.18, n0.4, p.1597-8, 2003) on their original paper (see ibid., vol.17, p.1142-52, 2002). The…”
Get full text
Journal Article -
13
Electrical design parameters of all-dielectric-self-supporting fiber optic cable
Published in IEEE transactions on power delivery (01-07-2000)“…A lumped circuit model for calculating voltages and currents on all-dielectric self-supporting (ADSS) fiber optic cable near high voltage transmission lines…”
Get full text
Journal Article -
14
Closure on "Use of global positioning system (GPS) receivers under power line conductors"
Published in IEEE transactions on power delivery (01-04-2003)“…As closure to the discussion of the original paper "Use of Global Positioning System (GPS) receivers under power line conductors" (see ibid., vol.17, p.938-44,…”
Get full text
Journal Article -
15
Discussion of "Calculation of electric field and potential distribution along nonceramic insulators considering the effects of conductors and transmission towers" [Closure to discussion]
Published in IEEE transactions on power delivery (01-10-2000)“…The author comments on the paper by T. Zhao et al. (see ibid., vol.15, no.1, p.313-18, 2000) with particular emphasis on the effect of weathersheds. The…”
Get full text
Journal Article -
16
A simple theory for optimizing finite width ELF magnetic field shields for minimum dependence on source orientation
Published in IEEE transactions on electromagnetic compatibility (01-11-1997)“…The effectiveness of single layer, finite width, planar extremely low frequency (ELF) magnetic field shields is strongly dependent upon the orientation of the…”
Get full text
Journal Article -
17
Portable ADSS surface contamination meter calibrated in high voltage environment
Published in IEEE transactions on power delivery (01-07-2003)“…All dielectric self-supporting (ADSS) fiber optic cable is known to have a limited service lifetime in some environments when installed near high voltage…”
Get full text
Journal Article -
18
An improved model for the electromagnetic compatibility of all-dielectric self-supporting fiber-optic cable and high-voltage power lines
Published in IEEE transactions on electromagnetic compatibility (01-08-1999)“…It has become common for utilities to locate optical-fiber communication systems on their transmission line towers. One type of cable used for this purpose is…”
Get full text
Journal Article -
19
Electromagnetic properties of dry and water saturated basalt rock, 1-110 GHz
Published in IEEE transactions on geoscience and remote sensing (01-05-1998)“…This paper reports on the measured electromagnetic properties of dry and water saturated basalt rock over a frequency range of 1-110 GHz. Tests were conducted…”
Get full text
Journal Article -
20
Magnetic fields from electric power lines: theory and comparison to measurements
Published in IEEE transactions on power delivery (01-10-1988)“…It is shown that currents and magnetic fields should be described statistically, because load currents fluctuate considerably during the day. The source…”
Get full text
Journal Article Conference Proceeding