Search Results - "Oller, J C"

Refine Results
  1. 1

    Energy and DOI Calibrations for High Spatial Resolution CZT Detectors by Carrascal, J., Castilla, J., Oller, J. C., Vela, O., Romero, L., Rato, P., Perez, J. M.

    Published in IEEE transactions on nuclear science (01-02-2014)
    “…In this paper we investigate the energy calibration methods of a high spatial resolution CdZnTe pixel detector, across a wide energy range, along with a fine…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Implementation of ITER Fast Plant Interlock System Using FPGAs With CompactRIO by Barrera, E., Ruiz, M., Bustos, A., Afif, M., Radle, B., Fernandez-Hernando, J. L., Prieto, I., Pedica, R., Barcala, J. M., Oller, J. C., Castro, R.

    Published in IEEE transactions on nuclear science (01-02-2018)
    “…Interlocks are the instrumented functions of ITER that protect the machine against failures of the plant system components or incorrect machine operation…”
    Get full text
    Journal Article
  4. 4
  5. 5

    A High Dynamic Range ASIC for Time of Flight PET with pixelated and monolithic crystals by Gomez, S., Sanchez, D., Gascon, D., Cela, J. M., Freixas, L., Graciani, R., Manera, R., Marin, J., Mauricio, J., Navarrete, J. J., Oller, J. C., Perez, J. M., Rato Mendes, P., Sanmukh, A., Vela, O.

    “…The HRFlexToT is a 16-channel ASIC for SiPM anode readout with common cathode connection. It is designed for Positron Emission Tomography (PET) applications…”
    Get full text
    Conference Proceeding
  6. 6

    Methodology for the deployment of ITER Fast Plant Interlock system. Use case: ITER Poloidal Field and Central Solenoid coil's power converter protection system by Barrera, E., Astrain, M., Prieto, I., Ruiz, M., Fernandez-Hernando, J.L., Pedica, R., Barcala, J.M., Oller, J.C., Afif, M.

    Published in Fusion engineering and design (01-04-2018)
    “…•ITER Interlock System protect the machine against failures•Programmable logic devices drastically reduce development time of interlocks.•Complex setups can be…”
    Get full text
    Journal Article
  7. 7

    Energy deposition by a 106Ru/ 106Rh eye applicator simulated using LEPTS, a low-energy particle track simulation by Fuss, M.C., Muñoz, A., Oller, J.C., Blanco, F., Williart, A., Limão-Vieira, P., Borge, M.J.G., Tengblad, O., Huerga, C., Téllez, M., García, G.

    Published in Applied radiation and isotopes (01-09-2011)
    “…The present study introduces LEPTS, an event-by-event Monte Carlo programme, for simulating an ophthalmic 106Ru/ 106Rh applicator relevant in brachytherapy of…”
    Get full text
    Journal Article
  8. 8
  9. 9

    Novel experimental setup for time-of-flight mass spectrometry ion detection in collisions of anionic species with neutral gas-phase molecular targets by Oller, J C, Ellis-Gibbings, L., da Silva, F. Ferreira, Limão-Vieira, P., García, G.

    Published in EPJ techniques and instrumentation (01-01-2015)
    “…We report a novel experimental setup for studying collision induced products resulting from the interaction of anionic beams with a neutral gas-phase molecular…”
    Get full text
    Journal Article
  10. 10

    Energy deposition model for I-125 photon radiation in water by Fuss, M. C., Muñoz, A., Oller, J. C., Blanco, F., Limão-Vieira, P., Williart, A., Huerga, C., Téllez, M., García, G.

    “…In this study, an electron-tracking Monte Carlo algorithm developed by us is combined with established photon transport models in order to simulate all primary…”
    Get full text
    Journal Article
  11. 11

    Performance test of the CMS link alignment system by Arce, P, Calvo, E, Figueroa, C.F, Garcı́a, N, Rodrigo, T, Vila, I, Virto, A.L, Barcala, J.M, Fernández, M.G, Ferrando, A, Josa, M.I, Molinero, A, Oller, J.C

    “…A first global test of the CMS Alignment System was performed at the I4 hall of the CERN ISR tunnel. Positions of the network, reproducing a set of points in…”
    Get full text
    Journal Article
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16
  17. 17

    First test of tiltmeters for the alignment system of CMS by Berdugo, J, Burgos, C, Fernández, M.G, Ferrando, A, Josa, M.I, Molinero, A, Oller, J.C, Salicio, J.M, Arce, P, Calvo, E, Figueroa, C.F, Garcı́a, N, Rodrigo, T, Vila, I, Virto, A.L

    “…In this note we present first tests done with the tiltmeters proposed as the key elements of the Laser Level systems to be used in the CMS alignment system…”
    Get full text
    Journal Article
  18. 18
  19. 19
  20. 20

    Charge sharing and interaction depth corrections in a wide energy range for small pixel pitch CZT detectors by Carrascal, J, Castilla, J, Oller, J C, Diaz, A, Vela, O, Romero, L, Perez, J M

    “…The CSTD project aims at developing a high resolution pixel gamma detector based on CdZnTe for Compton imaging applications. Our research group has been…”
    Get full text
    Conference Proceeding