Search Results - "Okada, Ryoma"

  • Showing 1 - 16 results of 16
Refine Results
  1. 1

    Polarization Image Sensor for Highly Sensitive Polarization Modulation Imaging Based on Stacked Polarizers by Sasagawa, Kiyotaka, Okada, Ryoma, Haruta, Makito, Takehara, Hironari, Tashiro, Hiroyuki, Ohta, Jun

    Published in IEEE transactions on electron devices (01-06-2022)
    “…In this article, We demonstrated an image sensor for detecting changes in polarization with high sensitivity. For this purpose, we constructed an optical…”
    Get full text
    Journal Article
  2. 2

    Millimeter-Wave Band Electro-Optical Imaging System Using Polarization CMOS Image Sensor and Amplified Optical Local Oscillator Source by Okada, Ryoma, Mizuno, Maya, Nagaoka, Tomoaki, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun, Sasagawa, Kiyotaka

    Published in Sensors (Basel, Switzerland) (26-06-2024)
    “…In this study, we developed and demonstrated a millimeter-wave electric field imaging system using an electro-optic crystal and a highly sensitive polarization…”
    Get full text
    Journal Article
  3. 3

    Exposure Time Control Method for Higher Intermediate Frequency in Optical Heterodyne Imaging and Its Application to Electric-Field Imaging Based on Electro-Optic Effect by Sasagawa, Kiyotaka, Okada, Ryoma, Akamatsu, Yoshihiro, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    Published in Sensors (Basel, Switzerland) (15-02-2024)
    “…We propose and demonstrate a method for equivalent time sampling using image sensors to selectively detect only the target frequency. Shortening the exposure…”
    Get full text
    Journal Article
  4. 4

    Investigating the Influence of Morphine and Cocaine on the Mesolimbic Pathway Using a Novel Microimaging Platform by Ganaway, Austin, Tatsuta, Kousuke, Castillo, Virgil Christian Garcia, Okada, Ryoma, Sunaga, Yoshinori, Ohta, Yasumi, Ohta, Jun, Ohsawa, Masahiro, Akay, Metin, Akay, Yasemin M

    “…Dopamine (DA)’s relationship with addiction is complex, and the related pathways in the mesocorticolimbic system are used to deliver DA, regulating both…”
    Get full text
    Journal Article
  5. 5

    Laser-carbonized Electrodes on Implantable CMOS-based Imaging Device for Simultaneous Deep-brain Optical and Electrophysiological Measurements by Castillo, Virgil Christian G., Tso, Kuang-Chih, Okada, Ryoma, Ohta, Yasumi, Sunaga, Yoshinori, Sasagawa, Kiyotaka, Ohta, Jun

    Published in Sensors and materials (12-07-2024)
    “…Optical and electrophysiological methods are widely used in neuroscience to study brain activity. Each technique has its own strengths and weaknesses that…”
    Get full text
    Journal Article
  6. 6

    Implantable Multimodal Sensing Device for Simultaneous Imaging and Electrophysiological Recording of Mouse Brain Activity by Sugie, Kenji, Sasagawa, Kiyotaka, Okada, Ryoma, Ohta, Yasumi, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    Published in Sensors and materials (28-09-2023)
    “…Optical and electrophysiological measurements help us understand mouse brain functions. One type of device available for optical measurements is an implantable…”
    Get full text
    Journal Article
  7. 7

    Multifunctional Implantable Device for Simultaneous Optical and Electrophysiological Measurements by Naganuma, Kyosuke, Ohta, Yasumi, Murakami, Takaaki E., Okada, Ryoma, Guinto, Mark Christian, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Sasagawa, Kiyotaka, Sunaga, Yoshinori, Akay, Yasemin M., Akay, Metin, Ohta, Jun

    Published in Sensors and materials (26-04-2022)
    “…In neuroscience, it is crucial to clarify the relationship between single-cell activity and neural network structure to understand brain neural activity. To…”
    Get full text
    Journal Article
  8. 8

    THz near-field intensity distribution imaging in the 0.3 THz band using a highly sensitive polarization CMOS image sensor using a 0.35 μm CMOS process by Okada, Ryoma, Mizuno, Maya, Nagaoka, Tomoaki, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun, Sasagawa, Kiyotaka

    Published in Japanese Journal of Applied Physics (01-03-2024)
    “…Abstract In this paper, we propose a low-disturbance and fast terahertz (THz) near-field intensity distribution imaging method. The THz detector is fabricated…”
    Get full text
    Journal Article
  9. 9

    Improvement of on-pixel polarizer with 0.35 μm CMOS process for electro-optic imaging systems by Okada, Ryoma, Sasagawa, Kiyotaka, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    Published in Japanese Journal of Applied Physics (01-04-2023)
    “…Abstract In this paper, we propose an improved on-pixel polarizer structure for an image sensor, which was fabricated using the 0.35 μ m standard CMOS process…”
    Get full text
    Journal Article
  10. 10

    Reflective high-sensitivity polarization change imaging using a dual polarizer structure by Sasagawa, Kiyotaka, Okada, Ryoma, Haruta, Makito, Takehara, Hironari, Tashiro, Hiroyuki, Ohta, Jun

    Published in Optics continuum (15-04-2023)
    “…In this study, we demonstrate a reflective imaging system in which a dual polarizer structure, consisting of a uniform polarizer and a polarizer on the pixel…”
    Get full text
    Journal Article
  11. 11

    105-GHz Electric Field Visualization by Electro-Optic Imaging System Using Polarization Image Sensor by Sasagawa, Kiyotaka, Okada, Ryoma, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    “…In this paper, we present a system designed for visualization of high-frequency electric field distributions at 105 GHz. Our approach employs an electro-optic…”
    Get full text
    Conference Proceeding
  12. 12

    Sensitivity improvement in electro-optic imaging based on polarization CMOS image sensor by Okada, Ryoma, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun, Sasagawa, Kiyotaka

    “…In this study, we discuss the maximum signal-to-noise ratio (SNR) at 1GHz in the electric field imaging system that we have developed using the electro-optic…”
    Get full text
    Conference Proceeding
  13. 13

    Frame Interval Control Technique for High-Frequency Electric Field Imaging by Equivalent-Time Sampling by Sasagawa, Kiyotaka, Akamatsu, Yoshihiro, Okada, Ryoma, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    “…We propose an equivalent-time sampling method with controlled frame spacing to improve the intermediate frequency of field imaging systems. Simple…”
    Get full text
    Conference Proceeding
  14. 14

    RF Electric Field Imaging Based on Electro-Optic Effect By Using a Global Shutter Polarization Camera by Sasagawa, Kiyotaka, Okada, Ryoma, Mizuno, Maya, Haruta, Makito, Takehara, Hironari, Tashiro, Hiroyuki, Ohta, Jun

    “…We demonstrate an electric field imaging system with a polarized image sensor, and perform equivalent sampling using a global shutter mechanism. We converted…”
    Get full text
    Conference Proceeding
  15. 15

    10-GHz Imaging by an Electro-Optic Imaging System Based on Polarization CMOS Image Sensor by Okada, Ryoma, Sasagawa, Kiyotaka, Mizuno, Maya, Takehara, Hironari, Haruta, Makito, Tashiro, Hiroyuki, Ohta, Jun

    Published in 2022 IEEE Photonics Conference (IPC) (01-11-2022)
    “…In this study, we demonstrate an electro-optic (EO) imaging system for 10 GHz. By using an optical modulator and an optical amplifier, we generated a…”
    Get full text
    Conference Proceeding
  16. 16

    Development of implantable multimodal sensor for optical and electrophysiological recording of mouse brain activity by Sugie, Kenji, Ohta, Yasumi, Haruta, Makito, Sasagawa, Kiyotaka, Okada, Ryoma, Takehara, Hironari, Tashiro, Hiroyuki, Ohta, Jun

    Published in 2022 IEEE Photonics Conference (IPC) (01-11-2022)
    “…In this study, we developed an implantable device for observing optical and electrophysiological signals from the mouse brain. The proposed multimodal sensor…”
    Get full text
    Conference Proceeding