Search Results - "OLaighin, Gearóid"
-
1
Development of a Body Sensor Network to Detect Motor Patterns of Epileptic Seizures
Published in IEEE transactions on biomedical engineering (01-11-2012)“…The objective of this study was the development of a remote monitoring system to monitor and detect simple motor seizures. Using accelerometer-based kinematic…”
Get full text
Journal Article -
2
Behaviour change techniques targeting both diet and physical activity in type 2 diabetes: A systematic review and meta-analysis
Published in The international journal of behavioral nutrition and physical activity (08-02-2017)“…Changing diet and physical activity behaviour is one of the cornerstones of type 2 diabetes treatment, but changing behaviour is challenging. The objective of…”
Get full text
Journal Article -
3
A Technological Review of Wearable Cueing Devices Addressing Freezing of Gait in Parkinson's Disease
Published in Sensors (Basel, Switzerland) (13-03-2019)“…Freezing of gait is one of the most debilitating symptoms of Parkinson's disease and is an important contributor to falls, leading to it being a major cause of…”
Get full text
Journal Article -
4
Effectiveness of a smartphone application to promote physical activity in primary care: the SMART MOVE randomised controlled trial
Published in British journal of general practice (01-07-2014)“…Physical inactivity is a major, potentially modifiable, risk factor for cardiovascular disease, cancer, and other chronic diseases. Effective, simple, and…”
Get full text
Journal Article -
5
Inertial Sensor Technology for Elite Swimming Performance Analysis: A Systematic Review
Published in Sensors (25-12-2015)“…Technical evaluation of swimming performance is an essential factor of elite athletic preparation. Novel methods of analysis, incorporating body worn inertial…”
Get full text
Journal Article Book Review -
6
A Continuous Wavelet Transform and Classification Method for Delirium Motoric Subtyping
Published in IEEE transactions on neural systems and rehabilitation engineering (01-06-2009)“…The usefulness of motor subtypes of delirium is unclear due to inconsistency in subtyping methods and a lack of validation with objective measures of activity…”
Get full text
Journal Article -
7
Editorial: Parkinson's disease: Technological trends for diagnosis and treatment improvement
Published in Frontiers in neurology (14-02-2023)Get full text
Journal Article -
8
Monitoring human health behaviour in one's living environment: A technological review
Published in Medical engineering & physics (01-02-2014)“…Abstract The electronic monitoring of human health behaviour using computer techniques has been an active research area for the past few decades. A wide array…”
Get full text
Journal Article -
9
When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors
Published in PloS one (13-01-2017)“…Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures…”
Get full text
Journal Article -
10
Diet Behavior Change Techniques in Type 2 Diabetes: A Systematic Review and Meta-analysis
Published in Diabetes care (01-12-2017)“…Dietary behavior is closely connected to type 2 diabetes. The purpose of this meta-analysis was to identify behavior change techniques (BCTs) and specific…”
Get full text
Journal Article -
11
Analysis of gait and balance through a single triaxial accelerometer in presymptomatic and symptomatic Huntington's disease
Published in Gait & posture (01-01-2013)“…Highlights ► The objective was to investigate the capacity of a single triaxial accelerometer in monitoring gait and balance in Huntington's disease subjects ►…”
Get full text
Journal Article -
12
Analysis of swimming performance: perceptions and practices of US-based swimming coaches
Published in Journal of sports sciences (02-06-2016)“…In elite swimming, a broad range of methods are used to assess performance, inform coaching practices and monitor athletic progression. The aim of this paper…”
Get full text
Journal Article -
13
Home detection of freezing of gait using support vector machines through a single waist-worn triaxial accelerometer
Published in PloS one (15-02-2017)“…Among Parkinson's disease (PD) symptoms, freezing of gait (FoG) is one of the most debilitating. To assess FoG, current clinical practice mostly employs…”
Get full text
Journal Article Publication -
14
Evaluation of the Finis Swimsense® and the Garmin Swim™ activity monitors for swimming performance and stroke kinematics analysis
Published in PloS one (08-02-2017)“…The study aims were to evaluate the validity of two commercially available swimming activity monitors for quantifying temporal and kinematic swimming…”
Get full text
Journal Article -
15
Double-Tap Interaction as an Actuation Mechanism for On-Demand Cueing in Parkinson's Disease
Published in Sensors (Basel, Switzerland) (26-11-2019)“…Freezing of Gait (FoG) is one of the most debilitating symptoms of Parkinson's disease and is an important contributor to falls. When the management of…”
Get full text
Journal Article -
16
Applicability and tolerability of electrical stimulation applied to the upper and lower leg skin surface for cueing applications in Parkinson's disease
Published in Medical engineering & physics (01-01-2021)“…•Sensory electrical stimulation should be applicable & tolerable for cueing in PwP.•Motor electrical stimulation should be applied with caution in PwP.•Upper…”
Get full text
Journal Article -
17
Design of a Planner-Based Intervention to Facilitate Diet Behaviour Change in Type 2 Diabetes
Published in Sensors (Basel, Switzerland) (06-04-2022)“…Diet behaviour is influenced by the interplay of the physical and social environment as well as macro-level and individual factors. In this study, we focus on…”
Get full text
Journal Article -
18
Parents' and healthcare professionals' perceptions of the use of live video recording in neonatal units: a focus group study
Published in BMC pediatrics (01-04-2020)“…The emerging use of video in neonatology units raises ethical and practical questions. This study aims to gain a better understanding of the suitability,…”
Get full text
Journal Article -
19
Validating a new clinical subtyping scheme for delirium with electronic motion analysis
Published in Psychiatry research (30-06-2010)“…Abstract The usefulness of motor subtypes of delirium is unclear due to inconsistency in sub-typing methods and a lack of validation with objective measures of…”
Get full text
Journal Article -
20
The development and preliminary evaluation of a clinician e-learning training platform for a neonatal sepsis risk monitor for use in ICU settings
Published in Applied ergonomics (01-05-2023)“…Training clinicians on the use of hospital-based patient monitoring systems (PMS) is vital to mitigate the risk of use errors and of frustration using these…”
Get full text
Journal Article