Search Results - "Nyenhuis, J.A."

Refine Results
  1. 1

    Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging by So, P.P.M., Stuchly, M.A., Nyenhuis, J.A.

    “…A heterogeneous model of the human body and the scalar potential finite difference method are used to compute electric fields induced in tissue by magnetic…”
    Get full text
    Journal Article
  2. 2

    Power deposition inside a phantom for testing of MRI heating by Amjad, A., Kamondetdacha, R., Kildishev, A.V., Park, S.M., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-10-2005)
    “…A patient in MRI is exposed to the time varying gradient and radio-frequency (RF) fields. Measurements of RF-induced temperature rise in implant in phantoms…”
    Get full text
    Journal Article Conference Proceeding
  3. 3

    MRI safety: RF-induced heating near straight wires by Park, S.M., Kamondetdacha, R., Amjad, A., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-10-2005)
    “…One of the most crucial magnetic resonance (MR) safety concerns is related to excessive heating of metallic implants by the radio frequency (RF) magnetic…”
    Get full text
    Journal Article Conference Proceeding
  4. 4

    Gelled versus nongelled phantom material for measurement of MRI-induced temperature increases with bioimplants by Park, S.M., Nyenhuis, J.A., Smith, C.D., Lim, E.J., Foster, K.S., Baker, K.B., Hrdlicka, G., Rezai, A.R., Ruggieri, P., Sharan, A., Shellock, F.G., Stypulkowski, P.H., Tkach, J.

    Published in IEEE transactions on magnetics (01-09-2003)
    “…Measurements in phantoms are used to predict temperature changes that would occur in vivo for medical implants due to the radio frequency (RF) field in…”
    Get full text
    Journal Article Conference Proceeding
  5. 5

    Simulation of human respiration in fMRI with a mechanical model by Brosch, J.R., Talavage, T.M., Ulmer, J.L., Nyenhuis, J.A.

    “…Obtaining functional magnetic resonance images of the brain is a challenging measurement process having a low characteristic signal-to-noise ratio. Images…”
    Get full text
    Journal Article
  6. 6

    Multipole characterization of a magnetic source using a truncated SVD by Kamondetdacha, R., Kildishev, A.V., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-07-2004)
    “…This paper presents a new technique for characterizing a magnetic source using truncated singular value decomposition (TSVD). It shows how the smallest…”
    Get full text
    Journal Article Conference Proceeding
  7. 7

    Multipole analysis of an elongated magnetic source by a cylindrical sensor array by Kildishev, A.V., Nyenhuis, J.A., Morgan, M.A.

    Published in IEEE transactions on magnetics (01-09-2002)
    “…This paper covers basics of the magnetic characterization of an elongated source. The core element of the work is to obtain a magnetic multipole image (MI) of…”
    Get full text
    Journal Article Conference Proceeding
  8. 8

    Multipole imaging of an elongated magnetic source by Kildishev, A.V., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-09-2000)
    “…This paper describes a mathematical method for modeling the magnetic field from an elongated source, a method that is relevant to the reduction of the magnetic…”
    Get full text
    Journal Article Conference Proceeding
  9. 9

    Method for detection of broken bars in induction motors by Dobrodeyev, P.N., Volokhov, S.A., Kildishev, A.V., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-09-2000)
    “…A method and apparatus for detection of broken bars in the rotor of a squirrel cage induction motor are described. The test method is easy to implement, no…”
    Get full text
    Journal Article Conference Proceeding
  10. 10

    Investigation of the magnetization process of domain walls in an iron-garnet film by direct optical observation of vertical Bloch lines by Fedyunin, Y., Friedlaender, F.J., Nyenhuis, J.A.

    Published in IEEE transactions on magnetics (01-09-1990)
    “…Vertical Bloch lines (VBL) were observed in a (YLuBi)/sub 3/(FeGa)/sub 5/O/sub 12/ magnetic garnet film from the light diffracted from the stripe domains…”
    Get full text
    Journal Article
  11. 11

    MRI and implanted medical devices: basic interactions with an emphasis on heating by Nyenhuis, J.A., Sung-Min Park, Kamondetdacha, R., Amjad, A., Shellock, F.G., Rezai, A.R.

    “…There are three principal magnetic fields in magnetic resonance imaging (MRI) that may interact with medical implants. The static field will induce force and…”
    Get full text
    Magazine Article
  12. 12

    Heating near implanted medical devices by the MRI RF-magnetic field by Nyenhuis, J.A., Kildishev, A.V., Bourland, J.D., Foster, K.S., Graber, G., Athey, T.W.

    Published in IEEE transactions on magnetics (01-09-1999)
    “…The temperature rise in the vicinity of a medical implant due to the RF field in Magnetic Resonance Imaging (MRI) was evaluated. For the calculations, the…”
    Get full text
    Journal Article Conference Proceeding
  13. 13

    Interactions of medical implants with the magnetic fields in MRI by Nyenhuis, J.A.

    “…Interactions of the static, gradient and radio frequency (RF) magnetic fields in a magnetic resonance (MR) imager with implanted medical devices are…”
    Get full text
    Conference Proceeding
  14. 14

    Comparison of rectangular and damped sinusoidal dB/dt waveforms in magnetic stimulation by Havel, W.J., Nyenhuis, J.A., Bourland, J.D., Foster, K.S., Geddes, L.A., Graber, G.P., Waninger, M.S., Schaefer, D.J.

    Published in IEEE transactions on magnetics (01-09-1997)
    “…In magnetic (eddy-current) stimulation, sensory and motor nerve are stimulated by a time-varying magnetic field (dB/dt) produced in an appropriate coil. In…”
    Get full text
    Journal Article
  15. 15

    Deperming technology in large ferromagnetic pipes by Kildishev, A.V., Nyenhuis, J.A., Dobrodeyev, P.N., Volokhov, S.A.

    Published in IEEE transactions on magnetics (01-09-1999)
    “…This report describes a deperming technique for reducing the arc blow effect in DC welding of ferromagnetic pipelines. The technique is based on compensation…”
    Get full text
    Journal Article Conference Proceeding
  16. 16
  17. 17

    Magnetic stimulation of excitable tissue: calculation of induced eddy-currents with a three-dimensional finite-element model by Mouchawar, G.A., Nyenhuis, J.A., Bourland, J.D., Geddes, L.A., Schaefer, D.J., Riehl, M.E.

    Published in IEEE transactions on magnetics (01-11-1993)
    “…The eddy-current distribution in a 3-D inhomogeneous model of a dog's thorax due to time varying fields in magnetic resonance imaging (MRI) x, y, and…”
    Get full text
    Journal Article Conference Proceeding
  18. 18

    Prediction of the magnetic field below an axisymmetrical planar sensor array with a magnetic source located above the measurement plane by Kildishev, A.V., Kamondetdacha, R., Nyenhuis, J.A.

    “…Summary form only given. Rapid advancements in magnetic sensor technology are creating opportunities for solving traditional problems of ship magnetism. Both…”
    Get full text
    Conference Proceeding
  19. 19

    Multipole imaging source by a cylindrical sensor array by Kildishev, A.V., Nyenhuis, J.A., Morgan, M.A.

    “…Summary form only given. In magnetic multipole imaging, the spheroidal expansions coefficients (c," , snm ) characterizing the magnetostatic potential are…”
    Get full text
    Conference Proceeding
  20. 20

    A comparison of phantom materials used in evaluation of radiofrequency heating of implanted medical devices during MRI by Smith, C.D., Nyenhuis, J.A., Foster, K.S.

    “…The safety of implanted medical devices within the magnetic resonance imaging (MRI) environment is an issue that must be continually addressed. All magnetic…”
    Get full text
    Conference Proceeding