Search Results - "Niu, BaoLian"
-
1
Optimization on jet‐induced ventilation to enhance the uniformity of airflow distribution in data center
Published in Energy science & engineering (01-11-2021)“…Improving the utilization efficiency of cold airflow in data center (DC) has already attracted widespread concern. A broad consensus has been reached that…”
Get full text
Journal Article -
2
Experimental study of the refrigeration cycle performance for the R744/R290 mixtures
Published in International journal of refrigeration (2007)“…A new binary mixture of R744 and R290 as an alternative natural refrigerant to R13 was first presented in this paper. Its environmental performance is…”
Get full text
Journal Article -
3
Multi-objective optimization of supply air jet enhancing airflow uniformity in data center using Taguchi/CRITIC/TOPSIS triple method
Published in Building and environment (01-10-2023)“…Jet fans have been introduced into under-floor air distribution systems as an active local measure to reduce hot spot temperatures and improve airflow…”
Get full text
Journal Article -
4
Preparation of n-OD@PMMA/PDA photothermal conversion microencapsulated phase change material and application of the suspensions in DASC
Published in Solar energy materials and solar cells (01-03-2024)“…A novel photothermal conversion microencapsulated phase change material (PDA-MPCM) was successfully prepared, contained n-octadecane (n-OD) as the core…”
Get full text
Journal Article -
5
Airflow uniformity and energy consumption investigation on data centers enhanced by jet fans
Published in HVAC&R research (21-04-2023)“…Active adjustment of the airflow organization in data centers (DC) has been increasingly applied due to its superior adjustment performance. But for now, the…”
Get full text
Journal Article -
6
Multi-objective optimization of supply air jet enhancing airflow uniformity in data center with Taguchi-based grey relational analysis
Published in Building and environment (15-01-2022)“…In most data centers (DCs), hot spots reduce the reliability, durability, and efficiency of server cooling. The hot spots are mainly attributed to the uneven…”
Get full text
Journal Article -
7
A review on evaluation metrics of thermal performance in data centers
Published in Building and environment (15-06-2020)“…The rapid development of cloud computing and big data has enabled large-scale applications of data centers over recent years. Characteristics and demands of…”
Get full text
Journal Article -
8
Research on the distribution characteristics of static pressure in data centers from the perspective of airflow transmission path
Published in Journal of Building Engineering (15-06-2024)“…A new observation perspective was proposed to manage the airflow distribution in data centers from the floor plenum and the cold aisle as a unified entity,…”
Get full text
Journal Article -
9
Simulation of the effect of the structure and location of non-closed droplet microchannel on flow/ thermal performance
Published in International communications in heat and mass transfer (01-11-2024)“…In order to investigate the effects of geometric parameters and flow modes on the fluid flow morphology, resistance and heat transfer effect in the non-closed…”
Get full text
Journal Article -
10
Numerical simulation of bubble growth in different nucleation positions and bubble merging near pin fin under the influence of non-closed droplet structure
Published in International communications in heat and mass transfer (01-12-2024)“…The microchannel heat transfer technology is a solution to the problem of efficiently dissipating heat in tight spaces. It's commonly used in electronic…”
Get full text
Journal Article -
11
Improving the Sierpinski carpet model arithmetic to accurately predict the thermal conductivity of fatty acid/carbon composite phase-change materials
Published in Thermal science and engineering progress (01-05-2023)“…•The GTC solution modifies the expression of the general solution of the dimensionless thermal conductivity.•The new formula called the FSC solution can narrow…”
Get full text
Journal Article -
12
Computational and experimental investigation of air supply duct structure in Air-Source water chiller test rooms
Published in Science & technology for the built environment (27-05-2020)“…Air source water chiller (ASWC) (8-90 kW) performance test rooms are expected to be built to manipulate the interior air field only within the prescribed…”
Get full text
Journal Article -
13
Investigation of occupant window opening behaviour during the summer period in a Beijing maternity hospital
Published in Journal of Building Engineering (01-01-2022)“…Window opening behavior in maternity hospital wards is the result of collective actions to create a healthy and comfortable recovery area for the patients and…”
Get full text
Journal Article -
14
Analysis of effective thermal conductivity for circular tubes made with porous media based on fractal theory
Published in Heat transfer (Hoboken, N.J. Print) (01-03-2022)“…Accurately evaluating the relation between heat transfer performance and the complex structure of porous media is still a difficult task. Most previous fractal…”
Get full text
Journal Article -
15
Optimization and analysis of structural parameters of extruded heat collector based on convective heat transfer of tube banks in crossflow
Published in Thermal science and engineering progress (01-03-2024)“…•The structural parameters of the extruded heat absorber are optimized.•Conical extruded absorber sink improves the heat transfer performance of PV/T…”
Get full text
Journal Article -
16
Study on the effect of refrigerant distributing nonuniformity on the performance of falling-film evaporator with liquid recirculation system
Published in International journal of refrigeration (01-10-2017)“…•A test facility of horizontal-tube falling-film water chiller is presented.•New method of dividing liquid distributor into subzones is employed.•Model of…”
Get full text
Journal Article -
17
A Permeability Model of Fractal Porous Media Composed of Arbitrary Shape Capillaries Based on Monte Carlo Simulation
Published in 2023 6th International Conference on Energy, Electrical and Power Engineering (CEEPE) (12-05-2023)“…The permeability plays a vital role in describing the Newtonian fluids in fractal porous media. Assuming that porous media consist of capillaries only with…”
Get full text
Conference Proceeding -
18
Computational and experimental investigation of air supply duct structure in Air-Source water chiller test rooms
Published in HVAC&R research (01-07-2020)“…Air source water chiller (ASWC) (8–90 kW) performance test rooms are expected to be built to manipulate the interior air field only within the prescribed…”
Get full text