Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
Published in European radiology (01-06-2018)“…Purpose To estimate potential dose reduction in abdominal CT by visually comparing images reconstructed with filtered back projection (FBP) and strengths of 3…”
Get full text
Journal Article -
2
Image quality in CT thorax: effect of altering reconstruction algorithm and tube load
Published in Radiation protection dosimetry (04-04-2024)“…Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-based IR algorithm (advanced…”
Get full text
Journal Article -
3
Assessment of image quality in abdominal computed tomography: Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction
Published in European journal of radiology (01-01-2020)“…•ADMIRE strength 3 renders images of acceptable clinical quality in abdominal CT.•For ADMIRE strength 5, dose reduction is limited to certain image…”
Get full text
Journal Article -
4
IMPLICATIONS OF PATIENT CENTRING ON ORGAN DOSE IN COMPUTED TOMOGRAPHY
Published in Radiation protection dosimetry (01-06-2016)“…Automatic exposure control (AEC) in computed tomography (CT) facilitates optimisation of dose absorbed by the patient. The use of AEC requires appropriate…”
Get full text
Journal Article -
5
Image quality and pathology assessment in CT Urography: when is the low-dose series sufficient?
Published in BMC medical imaging (09-08-2019)“…Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological…”
Get full text
Journal Article -
6
Efficient quality assurance programs in radiology and nuclear medicine in Östergötland, Sweden
Published in Radiation protection dosimetry (01-04-2010)“…Owners of imaging modalities using ionising radiation should have a documented quality assurance (QA) program, as well as methods to justify new radiological…”
Get full text
Journal Article -
7
Image quality in CT thorax: effect of altering reconstruction algorithm and tube load: Image quality in CT thorax
Published in Radiation protection dosimetry (2024)“…Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-basedIR algorithm (advanced…”
Get full text
Journal Article -
8
Estimation of the dose to the unborn child at diagnostic X-ray examinations based on data registrerad in RIS/PACS
Published in European radiology (2007)“…The aim of this work was to determine mean absorbed doses to the unborn child in common conventional X-ray and computed tomography (CT) examinations and to…”
Get full text
Journal Article -
9
VERIFICATION OF INDICATED SKIN ENTRANCE AIR KERMA FORCARDIAC X-RAY-GUIDED INTERVENTION USING GAFCHROMIC FILM
Published in Radiation protection dosimetry (2016)“…The aim of this work was to verify the indicated maximum entrance surface air kerma (ESAK) using a GE Innova IGS 520 imaging system during cardiac…”
Get full text
Journal Article -
10
Image quality assessments in abdominal CT: Relative importance of dose, iterative reconstruction strength and slice thickness
Published in Radiography (London, England. 1995) (01-10-2024)“…Low contrast resolution in abdominal computed tomography (CT) may be negatively affected by attempts to lower patient doses. Iterative reconstruction (IR)…”
Get full text
Journal Article -
11
IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW
Published in Radiation protection dosimetry (12-10-2021)“…Abstract Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the…”
Get full text
Journal Article -
12
Patient Organ Radiation Doses During Treatment for Aneurysmal Subarachnoid Hemorrhage
Published in Clinical neuroradiology (Munich) (01-12-2012)“…Purpose The aim of this retrospective study was to estimate risk organ doses and to estimate radiation risks during the imaging work-up and treatment for…”
Get full text
Journal Article -
13
Automatic tube-current modulation in CT—a comparison between different solutions
Published in Radiation protection dosimetry (01-01-2005)“…In this study, tube-current modulation systems on two different CT equipments have been evaluated: Care Dose from Siemens and Auto mA from GE Medical Systems…”
Get full text
Journal Article