Search Results - "Nigg, D.W."
-
1
Optimization of an accelerator-based epithermal neutron source for neutron capture therapy
Published in Applied radiation and isotopes (01-11-2004)“…A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton…”
Get full text
Journal Article -
2
Biodistribution of the boron carriers boronophenylalanine (BPA) and/or decahydrodecaborate (GB-10) for Boron Neutron Capture Therapy (BNCT) in an experimental model of lung metastases
Published in Applied radiation and isotopes (01-06-2014)“…BNCT was proposed for the treatment of diffuse, non-resectable tumors in the lung. We performed boron biodistribution studies with 5 administration protocols…”
Get full text
Journal Article -
3
A Feasibility and Optimization Study to Design a Nondestructive ATR Fuel Permanent Scanning System to Determine Fuel Burnup
Published in Nuclear data sheets (01-04-2014)“…The goal of this project was to develop the best available non-destructive technique to determine burnup of the Advanced Test Reactor (ATR) fuels at Idaho…”
Get full text
Journal Article -
4
Dosimetry and radiobiology at the new RA-3 reactor boron neutron capture therapy (BNCT) facility: Application to the treatment of experimental oral cancer
Published in Applied radiation and isotopes (01-07-2009)“…The National Atomic Energy Commission of Argentina (CNEA) constructed a novel thermal neutron source for use in boron neutron capture therapy (BNCT)…”
Get full text
Journal Article -
5
Spectral performance of a composite single-crystal filtered thermal neutron beam for BNCT research at the University of Missouri
Published in Applied radiation and isotopes (01-07-2009)“…Parameter studies, design calculations and initial neutronic performance measurements have been completed for a new thermal neutron beamline to be used for…”
Get full text
Journal Article -
6
Boron neutron capture therapy (BNCT) inhibits tumor development from precancerous tissue: An experimental study that supports a potential new application of BNCT
Published in Applied radiation and isotopes (01-07-2009)“…We previously demonstrated the efficacy of boron neutron capture therapy (BNCT) mediated by boronophenylalanine (BPA), GB-10 (Na 2 10B 10H 10) and (GB-10+BPA)…”
Get full text
Journal Article -
7
Boron neutron capture therapy (BNCT): Implications of neutron beam and boron compound characteristics
Published in Medical physics (Lancaster) (01-07-1999)“…The potential efficacy of boron neutron capture therapy (BNCT) for malignant glioma is a significant function of epithermal-neutron beam biophysical…”
Get full text
Journal Article -
8
Methods for radiation dose distribution analysis and treatment planning in boron neutron capture therapy
Published in International journal of radiation oncology, biology, physics (30-03-1994)“…This article presents a survey of recent progress in the development and application of analytical methods for calculating macroscopic and microscopic…”
Get more information
Journal Article -
9
Flux and instrumentation upgrade for the epithermal neutron beam facility at Washington State University
Published in Applied radiation and isotopes (01-11-2004)“…An epithermal neutron beam facility for preclinical neutron capture therapy research has been constructed at the Washington State University TRIGA research…”
Get full text
Journal Article -
10
MINERVA—a multi-modal radiation treatment planning system
Published in Applied radiation and isotopes (01-11-2004)“…Researchers at the Idaho National Engineering and Environmental Laboratory and Montana State University have undertaken development of MINERVA, a…”
Get full text
Journal Article -
11
Modelling of brain tissue substitutes for phantom materials in neutron capture therapy (NCT) dosimetry
Published in Radiation physics and chemistry (Oxford, England : 1993) (01-07-1999)“…The aim of this study was to define the most suitable brain tissue phantom material for neutron capture therapy (NCT). The calculated distributions of the…”
Get full text
Journal Article -
12
Demonstration of three-dimensional deterministic radiation transport theory dose distribution analysis for boron neutron capture therapy
Published in Medical physics (Lancaster) (01-01-1991)“…The Monte Carlo stochastic simulation technique has traditionally been the only well-recognized method for computing three-dimensional radiation dose…”
Get more information
Journal Article -
13
Macroscopic geometric heterogeneity effects in radiation dose distribution analysis for boron neutron capture therapy
Published in Medical physics (Lancaster) (01-05-1992)“…Calculations of radiation flux and dose distributions for boron neutron capture therapy (BNCT) of brain tumors are typically performed using sophisticated…”
Get more information
Journal Article -
14
Physics design for the Brookhaven Medical Research Reactor epithermal neutron source
Published in Basic life sciences (1990)“…A collaborative effort by researchers at the Idaho National Engineering Laboratory and the Brookhaven National Laboratory has resulted in the design and…”
Get more information
Journal Article