Search Results - "Niedbala, R. Sam"
-
1
Up-converting phosphor reporters for nucleic acid microarrays
Published in Nature biotechnology (01-03-2001)“…An important application of robotically spotted DNA microarrays is the monitoring of RNA expression levels. A clear limitation of this technology is the…”
Get full text
Journal Article -
2
Rapid Assay Format for Multiplex Detection of Humoral Immune Responses to Infectious Disease Pathogens (HIV, HCV, and TB)
Published in Annals of the New York Academy of Sciences (01-03-2007)“…: A novel assay is described for multiplex detection of antibodies against different pathogens from a single sample. The assay employs a modified lateral flow…”
Get full text
Journal Article -
3
Development of an ultrasensitive immunochromatography test to detect nicotine metabolites in oral fluids
Published in Analytical and bioanalytical chemistry (01-07-2011)“…Passive exposure to tobacco smoke causes a variety of illnesses ranging from allergic responses to cancer. Assessment of exposure to second-hand tobacco smoke…”
Get full text
Journal Article -
4
Use of Up-Converting Phosphor Reporters in Lateral-Flow Assays to Detect Specific Nucleic Acid Sequences: A Rapid, Sensitive DNA Test to Identify Human Papillomavirus Type 16 Infection
Published in Clinical chemistry (Baltimore, Md.) (01-10-2001)“…A lateral-flow (LF) device using the new reporter up-converting phosphor technology (UPT) was applied to DNA (hybridization) assays for the detection of…”
Get full text
Journal Article -
5
An amplification-free hybridization-based DNA assay to detect Streptococcus pneumoniae utilizing the up-converting phosphor technology
Published in Clinical biochemistry (01-07-2003)“…Development of a generally applicable sensitive hybridization-based assay devoid of any target amplification for the detection and identification of…”
Get full text
Journal Article -
6
Development of a Microfluidic Device for Detection of Pathogens in Oral Samples Using Upconverting Phosphor Technology (UPT)
Published in Annals of the New York Academy of Sciences (01-03-2007)“…: Confirmatory detection of diseases, such as HIV and HIV‐associated pathogens in a rapid point‐of‐care (POC) diagnostic remains a goal for disease control,…”
Get full text
Journal Article -
7
A Microfluidic System for Saliva-Based Detection of Infectious Diseases
Published in Annals of the New York Academy of Sciences (01-03-2007)“…: A “lab‐on‐a‐chip” system for detecting bacterial pathogens in oral fluid samples is described. The system comprises: (1) an oral fluid sample collector; (2)…”
Get full text
Journal Article -
8
Evaluation of UPlink-RSV: prototype rapid antigen test for detection of respiratory syncytial virus infection
Published in Annals of the New York Academy of Sciences (01-03-2007)“…A prototype rapid antigen test for the on-site detection of respiratory syncytial virus (RSV) infection was developed and evaluated. The platform uses…”
Get full text
Journal Article -
9
Automated Homogeneous Immunoassay Analysis of Cotinine in Urine
Published in Journal of analytical toxicology (01-04-2002)“…A study was conducted to evaluate the performance comparison of a homogeneous enzyme immunoassay (EIA) designed to detect cotinine in urine and carbon monoxide…”
Get full text
Journal Article -
10
Lateral-flow and up-converting phosphor reporters to detect single-stranded nucleic acids in a sandwich-hybridization assay
Published in Analytical biochemistry (15-01-2003)“…Up-converting Phosphor Technology (UPT) particles were used as reporters in lateral-flow (LF) assays to detect single-stranded nucleic acids. The 400-nm…”
Get full text
Journal Article -
11
Development of a Generic Microfluidic Device for Simultaneous Detection of Antibodies and Nucleic Acids in Oral Fluids
Published in BioMed research international (01-01-2013)“…A prototype dual-path microfluidic device (Rheonix CARD) capable of performing simultaneously screening (antigen or antibody) and confirmatory (nucleic acid)…”
Get full text
Journal Article -
12
Rapid prototyping of lateral flow assays
Published in Methods in molecular biology (Clifton, N.J.) (2009)“…Principles and characteristics of lateral flow strip assays are reviewed. Recent technology developments permit the use of inexpensive electronic readers for…”
Get more information
Journal Article -
13
Biomarker Discovery: Validation and Decision-Making in Product Development
Published in Sexually transmitted diseases (01-03-2009)“…The conference on which this supplement reports was organized to bring together microbicide researchers with researchers in the areas of drug prophylaxis and…”
Get full text
Journal Article Conference Proceeding -
14
Passive Cannabis Smoke Exposure and Oral Fluid Testing. II. Two Studies of Extreme Cannabis Smoke Exposure in a Motor Vehicle
Published in Journal of analytical toxicology (01-10-2005)“…Two studies were conducted to determine if extreme passive exposure to cannabis smoke in a motor vehicle would produce positive results for…”
Get full text
Journal Article -
15
Oral Fluid Testing for Drugs of Abuse: Positive Prevalence Rates by Intercept™ Immunoassay Screening and GC-MS-MS Confirmation and Suggested Cutoff Concentrations
Published in Journal of analytical toxicology (01-11-2002)“…Draft guidelines for the use of oral fluid for workplace drug testing are under development by the Substance Abuse and Mental Health Services Administration…”
Get full text
Journal Article -
16
High prevalence of 6-acetylmorphine in morphine-positive oral fluid specimens
Published in Forensic science international (23-04-2003)“…Identification of 6-acetylmorphine, a specific metabolite of heroin, is considered to be definitive evidence of heroin use. Although 6-acetylmorphine has been…”
Get full text
Journal Article Conference Proceeding -
17
Evaluation of UPlink-RSV
Published in Annals of the New York Academy of Sciences (01-03-2007)“…: A prototype rapid antigen test for the on‐site detection of respiratory syncytial virus (RSV) infection was developed and evaluated. The platform uses…”
Get full text
Journal Article -
18
Immunoassay for Detection of Cocaine/Metabolites in Oral Fluids
Published in Journal of analytical toxicology (01-01-2001)“…There is growing interest in the use of alternate biological fluids for drug testing. An advantage of oral fluids is that collection can be made from…”
Get full text
Journal Article -
19
Varying Results for Immunoassay Screening Kits for Cotinine Level
Published in Psychology of addictive behaviors (01-09-2002)“…Our earlier study found that although enzyme-linked immunosorbent analysis (ELISA) screening assays for urine cotinine indicated use in former smoking…”
Get full text
Journal Article -
20
M. tuberculosis Peptide based Point-of care test for TB
Published in BMC infectious diseases (27-05-2014)Get full text
Journal Article