Search Results - "Nichiporov, D."
-
1
Characterization of a GEM-based scintillation detector with He-CF4 gas mixture in clinical proton beams
Published in Physics in medicine & biology (21-04-2016)“…Accurate, high-spatial resolution dosimetry in proton therapy is a time consuming task, and may be challenging in the case of small fields, due to the lack of…”
Get more information
Journal Article -
2
Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking
Published in Medical physics (Lancaster) (01-11-2008)“…A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been…”
Get full text
Journal Article -
3
Range shift and dose perturbation with high-density materials in proton beam therapy
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (15-11-2011)“…Radiotherapy with proton beams requires accurate knowledge of the proton range. When materials with high atomic numbers ( Z) and densities (e.g. prostheses or…”
Get full text
Journal Article -
4
A GEM-based dose imaging detector with optical readout for proton radiotherapy
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2012)“…New techniques in proton radiation therapy and advances in beam delivery systems design such as beam scanning require accurate 2D dosimetry systems to verify…”
Get full text
Journal Article -
5
On the properties of n-type silicon diode detectors for clinical proton dosimetry
Published in Radiation measurements (01-12-2011)“…Silicon diodes of n-type produced at the Institute for Physical and Technical Problems (Russia) have been evaluated in two clinical proton beams with…”
Get full text
Journal Article -
6
SU‐E‐T‐10: A Computational Model for the Estimation of Biological Dose in a Clinical Proton Beam
Published in Medical Physics (01-06-2011)“…Purpose: The variability of relative biological effectiveness (RBE) of a proton beam with spatial distribution is well known. It is dependent on the proton…”
Get full text
Conference Proceeding Journal Article -
7
SU‐E‐T‐491: A FLUKA Monte Carlo Computational Model of a Scanning Proton Beam Therapy Nozzle at IU Proton Therapy Center
Published in Medical Physics (01-06-2012)“…Purpose: Charged particle therapy, especially proton therapy is a growing treatment modality worldwide. Monte Carlo (MC) simulation of the interactions of…”
Get full text
Conference Proceeding Journal Article -
8
Performance characteristics and long-term calibration stability of a beam monitor for a proton scanning gantry
Published in Radiation measurements (01-02-2011)“…A monitor for a uniformly scanned beam was designed and constructed by the Indiana University Cyclotron Facility for use in a clinical proton gantry at the…”
Get full text
Journal Article -
9
Evaluation of aluminum oxide fluorescent and OSL detectors in proton radiotherapy beams
Published in Radiation measurements (01-12-2011)“…Fluorescent Nuclear Track Detectors (FNTD) and Optically Stimulated Luminescence Detectors (OSLD) were investigated for application in proton therapy…”
Get full text
Journal Article Conference Proceeding -
10
SU‐E‐T‐206: A Patient Dose Monitor for a Proton Uniform Scanning Gantry
Published in Medical Physics (01-06-2011)“…Purpose: Discontinuation by the manufacturer of construction materials and several known design imperfections of the existing patient dose monitor (PDM) in our…”
Get full text
Conference Proceeding Journal Article -
11
Dose imaging detectors for radiotherapy based on gas electron multipliers
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2011)“…New techniques in charged particle therapy and widespread use of modern dynamic beam delivery systems demand new beam monitoring devices as well as accurate…”
Get full text
Journal Article -
12
SU‐GG‐T‐336: Effect of Treatment and Beam Parameters on Surface Dose in Proton Beam Therapy
Published in Medical Physics (01-06-2010)“…Purpose: The advantage of lower skin dose in proton beam therapy may result in less radiation‐related side effects which are typically seen in…”
Get full text
Conference Proceeding Journal Article -
13
SU‐FF‐T‐373: Investigation of Humidity Effects On Beam Monitor Performance in a Proton Clinical Gantry
Published in Medical Physics (01-06-2009)“…Purpose: To investigate the effect of ambient humidity on performance characteristics of ionization chambers used as beam monitors in two clinical proton…”
Get full text
Conference Proceeding Journal Article -
14
-
15
SU‐FF‐T‐328: Dose Perturbation and Range Shift with High‐Z Medium in Proton Beam
Published in Medical Physics (01-06-2009)“…Purpose: Treatment planning for proton beams requires accurate CT numbers to correlate with electron densities that define the proton range. When high atomic…”
Get full text
Conference Proceeding Journal Article -
16
-
17
TH‐C‐M100F‐06: Therapeutic Uniform Scanning Proton Beam Development and Characterization: Longitudinal Results
Published in Medical physics (Lancaster) (01-06-2007)“…Purpose: To utilize a new depth‐dose detector and to construct, develop, characterize and quantify longitudinal beam profiles with an active uniform scanning…”
Get full text
Journal Article -
18
-
19
41 POTENTIAL APPLICATIONS OF A GAS ELECTRON MULTIPLIER-BASED DETECTOR TO SMALL FIELD DOSIMETRY AND IMAGING IN PROTON THERAPY
Published in Radiotherapy and oncology (01-03-2012)Get full text
Journal Article -
20
TU‐FF‐A2‐04: Preliminary Radiological Characterization of An Active Proton Beam Spreading System for Therapeutic Use
Published in Medical Physics (01-06-2006)“…Purpose: At most proton therapy centers, a clinically useable radiation field is delivered by means of a passive beam spreading system. However, at this proton…”
Get full text
Conference Proceeding Journal Article