Search Results - "Newcomb, William L."
-
1
Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices
Published in Surgical endoscopy (01-01-2009)“…Background Bipolar electrosurgical devices and ultrasonic devices are routinely used in open and advanced laparoscopic surgery for hemostasis. New…”
Get full text
Journal Article -
2
Optimal treatment of hepatic abscess
Published in The American surgeon (01-02-2008)“…Many treatment strategies have been proposed for pyogenic liver abscesses; however, the indications for liver resection for treatment have not been studied in…”
Get more information
Journal Article -
3
Reversal of Hartmann’s procedure: A high-risk operation?
Published in Surgery (01-10-2007)“…Background Patients who undergo Hartmann’s procedure often do not have their colostomy closed based on the perceived risk of the operation. This study…”
Get full text
Journal Article -
4
Guidelines for Power and Time Variables for Microwave Ablation in an In Vivo Porcine Kidney
Published in The Journal of surgical research (15-05-2009)“…Purpose Microwave technology provides an emerging thermal ablation technique for solid organ tumors. We propose guidelines and recommend optimal time and power…”
Get full text
Journal Article -
5
Postoperative pulmonary embolism: timing, diagnosis, treatment, and outcomes
Published in The American journal of surgery (01-12-2007)“…Abstract Background Postoperative pulmonary embolism (PE) remains a major health concern. The purpose of our study was to evaluate our experience with…”
Get full text
Journal Article -
6
Antibiotic Prophylaxis in Colon Surgery
Published in Journal of the American College of Surgeons (01-07-2007)Get full text
Journal Article -
7
Hepatic tumor ablation with clustered microwave antennae: the US Phase II Trial
Published in HPB (Oxford, England) (01-04-2007)“…Background: Thermal ablation techniques have become important treatment options for patients with unresectable hepatic malignancies. Microwave ablation (MWA)…”
Get full text
Journal Article -
8
Pushing the envelope in biomaterial research: initial results of prosthetic coating with stem cells in a rat model
Published in Surgical endoscopy (01-11-2010)“…Background Coating prosthetic for hernia repair with a patient’s own cells could improve biocompatibility by decreasing inflammation and adhesion formation and…”
Get full text
Journal Article -
9
Comparing quality-of-life outcomes in symptomatic patients undergoing laparoscopic or open ventral hernia repair
Published in Journal of laparoendoscopic & advanced surgical techniques. Part A (01-08-2008)“…The aim of this study was to compare quality-of-life outcomes in patients with symptomatic hernias who were undergoing laparoscopic and open repairs. Clinical…”
Get more information
Journal Article -
10
Short-term outcomes after unilateral versus complete thyroidectomy for malignancy: a national perspective
Published in The American surgeon (01-01-2009)“…The extent of thyroidectomy for well-differentiated thyroid cancer (WDTC) remains controversial. We compared outcomes of patients undergoing unilateral thyroid…”
Get more information
Journal Article -
11
A comparison of gastrojejunal anastomoses with or without buttressing in a porcine model
Published in Surgical endoscopy (01-04-2009)“…Introduction The addition of staple-line reinforcements on circular anastomoses has not been well studied. We histologically and mechanically analyzed…”
Get full text
Journal Article -
12
Guidelines for Power and Time Variables for Microwave Ablation in a Porcine Liver
Published in Journal of gastrointestinal surgery (01-03-2008)“…The purpose of our study was to provide guidelines for the use of a novel microwave ablation system. Microwave ablations using a 915-MHz system were evaluated…”
Get full text
Journal Article -
13
An evaluation of electrosurgical vessel-sealing devices in biliary tract surgery in a porcine model
Published in HPB (Oxford, England) (01-12-2010)“…The purpose of this study was to evaluate two electrosurgical vessel-sealing devices in biliary surgery. Porcine common bile ducts (CBDs) were sealed with two…”
Get full text
Journal Article -
14
Safety and efficacy of the electrothermal bipolar vessel sealer in trauma
Published in Injury (01-05-2009)“…Summary The electrothermal bipolar vessel sealer (EBVS) was developed as an alternative to sutures, clips, and the ultrasonic scalpel for haemostasis during…”
Get full text
Journal Article -
15
Development of a functional, internet-accessible department of surgery outcomes database
Published in The American surgeon (01-06-2008)“…The need for surgical outcomes data is increasing due to pressure from insurance companies, patients, and the need for surgeons to keep their own "report…”
Get more information
Journal Article -
16
QS436. Stem Cell Coated Biomaterials a Possibility in Hernia Repair
Published in The Journal of surgical research (2008)Get full text
Journal Article -
17
Bursting strength evaluation in an experimental model of incisional hernia
Published in The American surgeon (01-01-2008)Get more information
Journal Article -
18
Guidelines for Power and Time Variables for Microwave Ablation in a Porcine Liver
Published in Journal of gastrointestinal surgery (01-03-2008)Get full text
Journal Article -
19
-
20
Abdominal Wall Reconstruction After Temporary Abdominal Closure: A Ten-Year Review
Published in Surgical Innovation (01-12-2006)“…Abdominal wall reconstruction (AWR) is often required for hernias created after temporary abdominal closure (TAC). Demographic and clinical data from patients…”
Get full text
Book Review Journal Article