Search Results - "Nevelos, J.E."

  • Showing 1 - 6 results of 6
Refine Results
  1. 1

    Wear of HIPed and non-HIPed alumina–alumina hip joints under standard and severe simulator testing conditions by Nevelos, J.E., Ingham, E., Doyle, C., Nevelos, A.B., Fisher, J.

    Published in Biomaterials (01-08-2001)
    “…Wear and the biological response to wear debris of artificial joints remain major concerns in total hip arthroplasty (THA). The long–term effects of UHMWPE…”
    Get full text
    Journal Article
  2. 2

    Alumina–alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision by Hatton, A., Nevelos, J.E., Nevelos, A.A., Banks, R.E., Fisher, J., Ingham, E.

    Published in Biomaterials (01-08-2002)
    “…The aims of this study were to investigate the tissues from uncemented Mittelmeier alumina ceramic-on-ceramic total hip replacements using histological methods…”
    Get full text
    Journal Article
  3. 3

    Alumina–alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations by Tipper, J.L., Hatton, A., Nevelos, J.E., Ingham, E., Doyle, C., Streicher, R., Nevelos, A.B., Fisher, J.

    Published in Biomaterials (01-08-2002)
    “…Until recently it was not possible to reproduce clinically relevant wear rates and wear patterns in in vitro hip joint simulators for alumina…”
    Get full text
    Journal Article
  4. 4

    Effects of clinically relevant alumina ceramic wear particles on TNF- α production by human peripheral blood mononuclear phagocytes by Hatton, A., Nevelos, J.E., Matthews, J.B., Fisher, J., Ingham, E.

    Published in Biomaterials (01-03-2003)
    “…The recent introduction of microseparation of the components of ceramic-on-ceramic hip prostheses during hip simulations has produced clinically relevant wear…”
    Get full text
    Journal Article
  5. 5

    Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses by Nevelos, J.E., Ingham, E., Doyle, C., Fisher, J., Nevelos, A.B.

    Published in Biomaterials (01-10-1999)
    “…This study analyses explanted prostheses from a single surgeon's 16-yr series of Mittelmeier cementless total hip replacements. The patient group was young…”
    Get full text
    Journal Article
  6. 6

    Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis by Ashraf, T, Newman, J.H, Desai, V.V, Beard, D, Nevelos, J.E

    Published in The knee (01-06-2004)
    “…Polyethylene wear is considered a threat to the long-term survival of unicompartmental knee replacement (UKR). This study aims to determine the linear…”
    Get full text
    Journal Article