Search Results - "Neto, Roberto Mendes Finzi"
-
1
On damage location techniques and future prospects for industrial applications utilizing the electromechanical impedance method: a systematic review
Published in Journal of the Brazilian Society of Mechanical Sciences and Engineering (01-05-2024)“…Structures and mechanical systems are constantly exposed to loads that result in damage occurrence, necessitating extensive monitoring. The electromechanical…”
Get full text
Journal Article -
2
Probabilistic Neural Network and Fuzzy Cluster Analysis Methods Applied to Impedance-Based SHM for Damage Classification
Published in Shock and vibration (01-01-2014)“…Impedance-based structural health monitoring technique is performed by measuring the variation of the electromechanical impedance of the structure caused by…”
Get full text
Journal Article -
3
Dehydration of turbine engine lubricant oil using cellulose hydrogel
Published in Colloids and surfaces. A, Physicochemical and engineering aspects (05-01-2025)“…Contamination of oils by water is a recurring problem in the industry and can damage engines and equipment. Oil dehydration systems with hydrogels have shown…”
Get full text
Journal Article -
4
SGS method applied to damage location and uncertainty modeling for sensor grid in the ISHM
Published in Comptes rendus. Mecanique (01-02-2024)Get full text
Journal Article -
5
Use of the electromechanical impedance method in the detection of inclusions: application to mammary tumors
Published in Structural health monitoring (01-05-2021)“…Breast cancer is a public health problem and has the highest incidence and mortality in the female population worldwide. Early detection of breast cancer is…”
Get full text
Journal Article -
6
Electromechanical Impedance - Based Structural Health Monitoring Instrumentation System Applied to Aircraft Structures and Employing a Multiplexed Sensor Array
Published in Journal of aerospace technology and management (01-09-2015)“…The electromechanical impedance method has been seen as a promising tool for structural health monitoring regarding different types of structures and purposes…”
Get full text
Journal Article -
7
Solid state switching and signal conditioning system for Structural Health Monitoring based on piezoelectric sensors actuators
Published in IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society (01-11-2011)“…The Structural Health Monitoring - SHM method based on electrical impedance has been developed as a promising tool for structure failure identification in real…”
Get full text
Conference Proceeding -
8
Reliability-based design of high-performance hydrocyclones: Multi-objective optimization, fabrication using 3D-printing and experimental analysis
Published in Powder technology (15-02-2024)“…In the literature, several works aim to improve the performance of hydrocyclones using geometry optimization. However, these approaches do not consider the…”
Get full text
Journal Article -
9
Impedance-based structural health monitoring and statistical method for threshold-level determination applied to 2024-T3 aluminum panels under varying temperature
Published in Structural health monitoring (01-07-2017)“…The impedance-based structural health monitoring method has become a promising and attractive tool for damage identification and is considered a nondestructive…”
Get full text
Journal Article -
10
A soft-switched current-controlled converter for induction machine drives
Published in IEEE transactions on power electronics (01-01-2001)“…The paper proposes a current controlled inverter operating in zero voltage switching (ZVS) mode for an induction machine drive. Operation with no voltage…”
Get full text
Journal Article -
11
Real-time structural health monitoring of fatigue crack on aluminum beam using an impedance-based portable device
Published in Journal of intelligent material systems and structures (01-12-2017)“…A common problem in aircraft maintenance is the development and detection of fatigue cracks in structural components with localized high-stress concentration…”
Get full text
Journal Article -
12
The use of Hurst exponent in impedance-based structural health monitoring
Published in Journal of the Brazilian Society of Mechanical Sciences and Engineering (01-11-2022)“…This work presents the use of the Hurst exponent in structural health monitoring based on the electromechanical impedance method. This technique uses…”
Get full text
Journal Article -
13
Impedance-based fault detection methodology for rotating machines
Published in Structural health monitoring (01-05-2015)“…Visual examination, ultrasonic tests, and dye penetrant inspection are some examples of nondestructive techniques widely used for crack detection in rotors…”
Get full text
Journal Article -
14
STATISTICAL PROCESS CONTROL (SPC) OF DAMAGE METRICS IN THE IMPEDANCE-BASED STRUCTURAL HEALTH MONITORING
Published in Revista Brasileira de Biometria (30-03-2021)“…Statistical Process Control (SPC) stands out for the use of control charts and for repeatability and reproducibility (R&R) techniques. This work aimed at its…”
Get full text
Journal Article -
15
Near-infrared vision system for monitoring arc welding processes
Published in Welding international (04-03-2015)“…Throughout the years, vision, human beings' favourite sense, along with our great capacity to obtain, process and interpret a great amount of visual data, has…”
Get full text
Journal Article -
16
A Soft Switching Half-Bridge Doubler Boost Converter Operating with Unity Power Factor
Published in Eletrônica de Potência (30-06-2005)“…This paper proposes a half-bridge doubler boost converter associated with an active commutation cell in order to minimize commutation losses. The converter…”
Get full text
Journal Article -
17
A high-power-factor half-bridge doubler boost converter without commutation losses
Published in IEEE transactions on industrial electronics (1982) (01-10-2005)“…This paper proposes a high-power-factor half-bridge doubler boost converter without commutation losses, which provides high output voltages, i.e., from 600 to…”
Get full text
Journal Article -
18
System for Structural Health Monitoring based on piezoelectric sensors/actuators
Published in XI Brazilian Power Electronics Conference (01-09-2011)“…The Structural Health Monitoring - SHM method based on electrical impedance has been developed as a promising tool for structure failure identification in real…”
Get full text
Conference Proceeding -
19
Monitoreo de salud estructural de aeronaves basado en mediciones de impedancia electromecanica
Published in Avances (Universidad Libre) (01-07-2011)“…Se denomina Monitoreo de Salud Estructural al proceso de detección de anomalías (daños o degradación) en varias áreas de ingeniería, tales como, aeroespacial,…”
Get full text
Journal Article