Search Results - "Nachab, A"
-
1
Probing new physics models of neutrinoless double beta decay with SuperNEMO
Published in The European physical journal. C, Particles and fields (01-12-2010)“…The possibility to probe new physics scenarios of light Majorana neutrino exchange and right-handed currents at the planned next generation neutrinoless double…”
Get full text
Journal Article -
2
Update of (40)K and (226)Ra and (232)Th series γ-to-dose conversion factors for soil
Published in Journal of environmental radioactivity (01-12-2014)“…Over the last four decades, the dose conversion factors used to calculate external exposure to γ radiation from soil from (40)K and the (226)Ra and (232)Th…”
Get full text
Journal Article -
3
Dosimeter incorporating radiophotoluminescent detectors for thermal neutrons and γ-rays in n-γ fields
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (15-10-2016)“…We have developed a dosimeter associating different neutron converters with two radiophotoluminescent detectors to measure thermal neutrons and γ-rays in a…”
Get full text
Journal Article -
4
Elemental composition effects on self-absorption for photons below 100keV in gamma-ray spectrometry
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-07-2014)“…The influence of elemental composition in the self-absorption phenomenon is observed. The effective atomic number (Zeff) is used to explain this influence for…”
Get full text
Journal Article -
5
Update of 40K and 226Ra and 232Th series γ-to-dose conversion factors for soil
Published in Journal of environmental radioactivity (01-12-2014)“…Over the last four decades, the dose conversion factors used to calculate external exposure to γ radiation from soil from 40K and the 226Ra and 232Th chains…”
Get full text
Journal Article -
6
Low background germanium planar detector for gamma-ray spectrometry
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-04-2011)“…A new ultra-low background planar germanium spectrometer has been developed. The planar geometry improves the sensitivity and energy resolution below 600 keV…”
Get full text
Journal Article -
7
Measurement of the background in the NEMO 3 double beta decay experiment
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-07-2009)“…In the double beta decay experiment NEMO 3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the…”
Get full text
Journal Article -
8
Characterization of a PN3 personal neutron dosimeter based on (n,α) reaction
Published in Results in physics (01-01-2015)“…•We have experimentally calibrated passive detectors with thermal neutrons.•Thermal neutron was generated by (252Cf+D2O) source.•PN3 track detector was…”
Get full text
Journal Article -
9
Evidence of 131I and (134,137)Cs activities in Bordeaux, France due to the Fukushima nuclear accident
Published in Journal of environmental radioactivity (01-12-2012)“…Following the Fukushima nuclear accident, low-background gamma spectrometry measurements were performed with HPGe detectors at the PRISNA platform located at…”
Get full text
Journal Article -
10
Evidence of 131I and 134,137Cs activities in Bordeaux, France due to the Fukushima nuclear accident
Published in Journal of environmental radioactivity (01-12-2012)“…Following the Fukushima nuclear accident, low-background gamma spectrometry measurements were performed with HPGe detectors at the PRISNA platform located at…”
Get full text
Journal Article -
11
A new environmental dosimeter with imaging plates for the fast neutron monitoring
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-01-2005)“…We describe a dosimeter incorporating BaFBr:Eu2+ imaging plates (IPs) for fast neutron ambient dose equivalent measurements. Its configuration and some of its…”
Get full text
Journal Article -
12
MCNPX simulation for α -particle detection by CMOS active pixel sensor
Published in Radiation Measurements (01-11-2005)“…This work assesses the performance of the CMOS electronic system for α -particle detection from sources and in a 222Rn atmosphere and compares the experimental…”
Get full text
Journal Article Conference Proceeding -
13
Uranium analysis of sediments by γ-ray spectrometry with corrections for self-absorption
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (2004)“…We have applied the MCNP Monte Carlo program to calculate γ-ray counting efficiencies and the separate influences of sample density and composition in two of…”
Get full text
Journal Article -
14
Calibration factor for estimating personal dose equivalent with imaging plates
Published in Radiation Measurements (01-11-2005)“…A personal imaging plate (IP) dosimeter is in the process of being developed for neutron fields using the BaFBr: Eu 2 + phosphor. A configuration incorporating…”
Get full text
Journal Article Conference Proceeding -
15
Measurement of double beta decay of 100Mo to excited states in the NEMO 3 experiment
Published in Nuclear physics. A (2007)“…The double beta decay of 100Mo to the 0 1 + and 2 1 + excited states of 100Ru is studied using the NEMO 3 data. After the analysis of 8024 h of data the…”
Get full text
Journal Article -
16
210Pb activity by detection of bremsstrahlung in 210Bi β-decay
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-03-2012)“…A method for the determination of the 210Pb activity by HPGe spectrometry is proposed, consisting of measuring the bremsstrahlung generated in a sample by…”
Get full text
Journal Article -
17
Comparison of imaging plates with track detectors for fast-neutron dosimetry
Published in Radiation protection dosimetry (01-01-2004)“…Imaging plate (IP) radiation detectors are widely used in industrial radiography, medical imagery and autoradiography. When an IP is exposed to ionising…”
Get full text
Journal Article -
18
Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector
Published in Nuclear physics. A (08-12-2010)“…Using 9.4 g of 96Zr isotope and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg y, the obtained 2 ν β β decay half-life measurement is T 1…”
Get full text
Journal Article -
19
Study of a new neutron dosimeter incorporating RPL detectors
Published in Radiation measurements (01-12-2015)“…We characterize a passive dosimeter incorporating RadioPhotoLuminescent (RPL) detectors capable of measuring both fast and thermal neutrons for personal…”
Get full text
Journal Article -
20
Update of super(40)K and super(226)Ra and super(232)Th series gamma -to-dose conversion factors for soil
Published in Journal of environmental radioactivity (01-12-2014)“…Over the last four decades, the dose conversion factors used to calculate external exposure to gamma radiation from soil from super(40)K and the super(226)Ra…”
Get full text
Journal Article