Search Results - "Muzic, R.F"

  • Showing 1 - 15 results of 15
Refine Results
  1. 1
  2. 2
  3. 3

    Distributed versus compartment models for PET receptor studies by Muzic, R.F., Saidel, G.M.

    Published in IEEE transactions on medical imaging (01-01-2003)
    “…Although distributed models are generally accepted as being more realistic than compartment models, use of simpler compartment models is pervasive in nuclear…”
    Get full text
    Journal Article
  4. 4
  5. 5

    Optimal experiment design for PET quantification of receptor concentration by Muzic, R.F., Nelson, A.D., Saidel, G.M., Miraldi, F.

    Published in IEEE transactions on medical imaging (01-02-1996)
    “…The mathematical models used to analyze positron emission tomography (PET) data obtained for receptor quantitation have many unknown parameters which must be…”
    Get full text
    Journal Article
  6. 6

    PET Performance of the GEMINI TF: A Time-of-flight PET/CT Scanner by Muzic, R.F., Kolthammer, J.A.

    “…We present a summary of the performance of a new-generation of commercial PET/CT scanners with time-of-flight (TOF) capability. The Philips GEMINI TF uses…”
    Get full text
    Conference Proceeding
  7. 7

    A method to correct for scatter, spillover, and partial volume effects in region of interest analysis in PET by Muzic, R.F., Chi-Hsien Chen, Nelson, A.D.

    Published in IEEE transactions on medical imaging (01-04-1998)
    “…Scatter and spatial resolution effects degrade the accuracy of radioactivity concentration estimates obtained from positron emission tomography (PET) data. The…”
    Get full text
    Journal Article
  8. 8

    Temporal alignment of tissue and arterial data and selection of integration start times for the H/sub 2//sup 15/O autoradiographic CBF model in PET by Muzic, R.F., Nelson, A.D., Miraldi, F.

    Published in IEEE transactions on medical imaging (01-09-1993)
    “…A technique has been developed and tested that provides an automated method of temporally aligning the PET tissue activity curve with the arterial activity…”
    Get full text
    Journal Article
  9. 9

    A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET by Chi-Hsien Chen, Muzic, R.F., Nelson, A.D., Adler, L.P.

    Published in IEEE transactions on medical imaging (01-04-1998)
    “…Accurate quantitation of small lesions with positron emission tomography (PET) requires correction for the partial volume effect. Traditional methods that use…”
    Get full text
    Journal Article
  10. 10

    Comments, with reply, on "Monte Carlo simulation of BaF/sub 2/ detectors used in time-of-flight positron emission tomography" by A.N. Bice et al by Muzic, R.F., Nelson, A.D., Miraldi, F.

    Published in IEEE transactions on nuclear science (01-04-1991)
    “…The commenters point out an error in Fig.2 of the above-named work of A.N. Bice et al. (see ibid., vol.37, no.2, p.696-701, April 1990). The error arose…”
    Get full text
    Journal Article
  11. 11

    Measurement of human cerebral blood flow with [15O]butanol and positron emission tomography by Berridge, M S, Adler, L P, Nelson, A D, Cassidy, E H, Muzic, R F, Bednarczyk, E M, Miraldi, F

    “…Although H2(15)O is widely used for CBF measurement by positron tomography, it underestimates CBF, especially at elevated flow rates. Several tracers,…”
    Get more information
    Journal Article
  12. 12

    Temporal alignment of tissue and arterial data and selection of integration start times for the H(2)(15)O autoradiographic CBF model in PET by Muzic, Jr, R F, Nelson, A D, Miraldi, F

    Published in IEEE transactions on medical imaging (01-09-1993)
    “…A technique has been developed and tested that provides an automated method of temporally aligning the PET tissue activity curve with the arterial activity…”
    Get full text
    Journal Article
  13. 13

    Mathematical simplification of a PET blood flow model by Muzic, R.F., Nelson, A.D., Miraldi, F.

    Published in IEEE transactions on medical imaging (01-06-1990)
    “…The positron emission tomography (PET) H/sub 2//sup 15/O bolus injection model for cerebral blood flow (CBF) requires calculation of a certain double integral…”
    Get full text
    Journal Article
  14. 14

    Monte Carlo simulation of a TOF PET scanner. I. Preliminary report by Muzic, R.F., Nelson, A.D., Miraldi, F.

    “…A Monte Carlo simulation was developed to study scattered radiation in the SP3000 (Scanditronix/PETT) time-of-flight (TOF) positron emission tomography (PET)…”
    Get full text
    Conference Proceeding
  15. 15

    Non-invasive arterial monitor for H2/sup 15/O blood flow studies by Nelson, A.D., Miraldi, F., Leisure, G.P., Muzic, R.F.

    “…A noninvasive arterial radioactivity monitor has been developed that measures the flux of photons emanating from the superior lobe of the right lung following…”
    Get full text
    Conference Proceeding