Search Results - "Muehlsteff, J."
-
1
Systolic blood pressure estimation using PPG and ECG during physical exercise
Published in Physiological measurement (01-12-2016)“…In this work, a model to estimate systolic blood pressure (SBP) using photoplethysmography (PPG) and electrocardiography (ECG) is proposed. Data from 19…”
Get more information
Journal Article -
2
Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis
Published in Physiological measurement (01-12-2014)“…The presence of motion artifacts in photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular parameters…”
Get more information
Journal Article -
3
Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram
Published in Physiological measurement (01-09-2015)“…Monitoring of cardiovascular function on a beat-to-beat basis is fundamental for protecting patients in different settings including emergency medicine and…”
Get more information
Journal Article -
4
Real-Time Prediction of Neurally Mediated Syncope
Published in IEEE journal of biomedical and health informatics (01-03-2016)“…Neurally mediated syncope (NMS) patients suffer from sudden loss of consciousness, which is associated with a high rate of falls and hospitalization. NMS…”
Get full text
Journal Article -
5
Beat-to-beat systolic time-interval measurement from heart sounds and ECG
Published in Physiological measurement (01-02-2012)“…Systolic time intervals are highly correlated to fundamental cardiac functions. Several studies have shown that these measurements have significant diagnostic…”
Get more information
Journal Article -
6
Can PPG be used for HRV analysis?
Published in 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-08-2016)“…Heart rate variability (HRV) represents one of the most promising markers of the autonomic nervous system (ANS) regulation. However, it requires the…”
Get full text
Conference Proceeding Journal Article -
7
Evaluation of a PPG-based algorithm for prediction of neurally mediated syncope
Published in 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) (01-02-2016)“…Syncope is a transient and self-limited loss of consciousness that affects mostly elderly people. Although it is not lethal it can lead to serious injuries and…”
Get full text
Conference Proceeding Journal Article -
8
Insights into oscillometry: An Experimental Study for Improvement of Cuff-Based Blood Pressure Measurement Technology
Published in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-07-2019)“…Non-invasive blood pressure (BP) measurements are usually performed by means of an empirical interpretation of arterial oscillations recorded via cuff based…”
Get full text
Conference Proceeding Journal Article -
9
Feasibility of in-vivo estimation of the brachial artery area-pressure relation from CINE and real-time MRI during upper arm cuff inflations
Published in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-07-2019)“…Objective: We investigate the basic feasibility of estimating the brachial artery area-pressure relationship from MRI data obtained during pressure cuff…”
Get full text
Conference Proceeding Journal Article -
10
Cuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period
Published in 2006 International Conference of the IEEE Engineering in Medicine and Biology Society (2006)“…This paper investigates the specific contributions of the pre-ejection period (PEP) and pulse transit time (PTT) for blood pressure estimation based on the…”
Get full text
Conference Proceeding Journal Article -
11
Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population?
Published in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology (01-01-2010)“…The Pulse Transit Time (PTT) is generally assumed to be a good surrogate measure to comfortably track blood pressure (BP) and blood pressure changes. This…”
Get full text
Conference Proceeding Journal Article -
12
Artifact detection in accelerometer signals acquired from the carotid
Published in 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (01-07-2017)“…Manual pulse palpation is the common procedure to assess pulse in unconscious patients. This is an error prone procedure during cardiopulmonary resuscitation…”
Get full text
Conference Proceeding Journal Article -
13
Personalization of pulse arrival time based blood pressure surrogates through single spot check measurements
Published in 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) (01-11-2021)“…Objective: We investigate the effect of selective single parameter personalization on the performance of multi-parameter models for pulse arrival time (PAT)…”
Get full text
Conference Proceeding Journal Article -
14
Optimized non-uniform sampling of blood pressure time series from the operating room
Published in 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) (01-07-2020)“…Objective: We investigate an optimized non-uniform sampling strategy for blood pressure time series from the operating room (OR). Our aim is to obtain an…”
Get full text
Conference Proceeding -
15
Detection of motion artifacts in photoplethysmographic signals based on time and period domain analysis
Published in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2012)“…The presence of motion artifacts in the photoplethysmographic (PPG) signals is one of the major obstacles in the extraction of reliable cardiovascular…”
Get full text
Conference Proceeding Journal Article -
16
Method for measurement of arterial compliance by fusion of oscillometry and pulse wave velocity
Published in 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) (01-07-2020)“…Up until now estimation of arterial compliance has been performed either by analysis of arterial pressure changes with respect to volume changes or by…”
Get full text
Conference Proceeding -
17
Comparison of systolic time interval measurement modalities for portable devices
Published in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology (01-01-2010)“…Systolic time intervals (STI) have shown significant diagnostic and prognostic value to assess the global cardiac function. Their value has been largely…”
Get full text
Conference Proceeding Journal Article -
18
Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: The impact of posture
Published in 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2008)“…There is an unmet need for cuff-less blood pressure (BP) monitoring especially, in personal healthcare applications. The pulse arrival time (PAT) approach…”
Get full text
Conference Proceeding Journal Article -
19
Multi-Gaussian fitting for the assessment of left ventricular ejection time from the Photoplethysmogram
Published in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (01-01-2012)“…The Left ventricular ejection time (LVET) is one of the primary surrogates of the left ventricular contractility and stroke volume. Its continuous monitoring…”
Get full text
Conference Proceeding Journal Article -
20
Algorithm for real-time prediction of neurally mediated syncope integrating indexes of autonomic modulation
Published in 2015 Computing in Cardiology Conference (CinC) (01-09-2015)“…Neurally mediated syncope (NMS) is a transient and self-limited loss of consciousness that affects all ages and is associated with high rates of falls and…”
Get full text
Conference Proceeding Journal Article