Search Results - "Monajemi, T. T."
-
1
Application of plastic scintillating fibres to surface dosimetry in megavoltage photon and electron beams: considerations for Cerenkov correction
Published in Physics in medicine & biology (10-09-2018)“…This work investigated the application of plastic scintillation detectors (PSDs) in dosimetry measurements on the surface of a phantom in megavoltage photon…”
Get more information
Journal Article -
2
In search of a one plan solution for VMAT post‐mastectomy chest wall irradiation
Published in Journal of applied clinical medical physics (01-08-2020)“…Purpose This study was designed to evaluate skin dose in both VMAT and tangent treatment deliveries for the purpose of identifying suitable bolus use protocols…”
Get full text
Journal Article -
3
PO-226 INCORPORATING EDEMA IN PROSTATE SEED IMPLANT DOSIMETRY USING A CLINICALLY-INFORMED EDEMA MODEL
Published in Radiotherapy and oncology (01-05-2012)Get full text
Journal Article -
4
Thick, segmented CdWO4‐photodiode detector for cone beam megavoltage CT: A Monte Carlo study of system design parameters
Published in Medical physics (Lancaster) (01-12-2006)“…Megavoltage (MV) imaging detectors have been the focus of research by many groups in recent years. We have been working with segmented CdWO4 crystals in…”
Get full text
Journal Article -
5
A bench‐top megavoltage fan‐beam CT using CdWO4‐photodiode detectors. II. Image performance evaluation
Published in Medical physics (Lancaster) (01-04-2006)“…Megavoltage computed tomography (MVCT) is a potential imaging tool for positioning and dose delivery verification during image guided radiotherapy. The problem…”
Get full text
Journal Article -
6
TH‐C‐303A‐06: Performance Characterization of a MVCT Scanner Using Multi‐Slice Thick, Segmented Cadmium Tungstate‐Photodiode Detectors
Published in Medical Physics (01-06-2009)“…Purpose: To evaluate the performance of a MVCT system based on multi‐slice, thick, and segmented cadmium tungstate‐photodiode detectors. Method and Materials:…”
Get full text
Conference Proceeding Journal Article -
7
A bench‐top megavoltage fan‐beam CT using CdWO4‐photodiode detectors. I. System description and detector characterization
Published in Medical physics (Lancaster) (01-04-2006)“…We describe the components of a bench‐top megavoltage computed tomography (MVCT) scanner that uses an 80‐element detector array consisting of CdWO4…”
Get full text
Journal Article -
8
Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema
Published in Medical physics (Lancaster) (01-04-2011)“…Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated…”
Get full text
Journal Article -
9
Modeling scintillator-photodiodes as detectors for megavoltage CT
Published in Medical physics (Lancaster) (01-05-2004)“…The use of cadmium tungstate ( CdWO 4 ) and cesium iodide [CsI(Tl)] scintillation detectors is studied in megavoltage computed tomography (MVCT). A model…”
Get full text
Journal Article -
10
Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors
Published in Medical physics (Lancaster) (01-01-2010)“…Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior…”
Get full text
Journal Article -
11
Impact of edema and seed movement on the dosimetry of prostate seed implants
Published in Journal of medical physics (01-04-2012)“…This article summarizes current knowledge concerning the characterization of prostatic edema and intra-prostatic seed movement as these relate to dosimetry of…”
Get full text
Journal Article -
12
TU‐FF‐A3‐01: X‐Ray and Optical Monte Carlo Study of Thick, Segmented Scintillators for MV Imaging
Published in Medical Physics (01-06-2006)“…Purpose: To study the imaging characteristics of thick, segmented, 2‐D CdWO4 crystal‐photodiode detectors as a function of crystal height, septa material and…”
Get full text
Conference Proceeding Journal Article -
13
OC-0617 Camera-based in-vivo dosimetry using dual-material 3D printed scintillator arrays
Published in Radiotherapy and oncology (01-05-2022)Get full text
Journal Article -
14
Sci‐PM Sat ‐ 01: Imaging performance of a bench‐top megavoltage CT scanner
Published in Medical physics (Lancaster) (01-07-2005)“…The ultimate goal of this project is to create a focused 2D MV detector with high detective quantum efficiency so reasonable low contrast resolution (LCR) at…”
Get full text
Journal Article -
15
TU‐C‐I‐609‐10: Preliminary Study of Pixel Pitch and Effect of Divergence On Thick Cadmium Tungstate Detector
Published in Medical physics (Lancaster) (01-06-2005)“…Purpose: To theoretically study the effects of pixel pitch and beam divergence on 1 cm thick CdWO 4 crystals for use in megavoltage cone beam computed…”
Get full text
Journal Article -
16
TU‐EE‐A3‐03: Performance of a Bench‐Top, Megavoltage CT (MVCT) Scanner Using Cadmium Tungstate‐Photodiodes
Published in Medical physics (Lancaster) (01-06-2005)“…Purpose: To evaluate the imaging performance of a prototype fan‐beam megavoltage CT (MVCT) scanner in Co 60 and 6 MV beams. Method and Materials: The…”
Get full text
Journal Article -
17
PO-1335: Characterization of novel 3D printed plastic scintillation dosimeters
Published in Radiotherapy and oncology (01-11-2020)Get full text
Journal Article -
18
Po‐Poster ‐ 01: A bench‐top megavoltage CT scanner
Published in Medical physics (Lancaster) (01-07-2005)“…The purpose of this project was to design, fabricate and test the data acquisition timing control, precision rotary stage control, and analog data multiplexer…”
Get full text
Journal Article -
19
SU‐FF‐I‐05: A Bench‐Top Megavoltage CT (MVCT) Scanner with Cadmium Tungstate‐Photodiode Detectors
Published in Medical physics (Lancaster) (01-06-2005)“…Purpose: To design, fabricate and test the data acquisition timing control, precision rotary stage control, and an analog data multiplexer unit for a prototype…”
Get full text
Journal Article -
20
Thick, segmented ‐photodiode detector for cone beam megavoltage CT: A Monte Carlo study of system design parameters
Published in Medical physics (Lancaster) (01-12-2006)“…Megavoltage (MV) imaging detectors have been the focus of research by many groups in recent years. We have been working with segmented crystals in contact with…”
Get full text
Journal Article