Search Results - "Moerman, Kevin M"

Refine Results
  1. 1

    MultiDIC: An Open-Source Toolbox for Multi-View 3D Digital Image Correlation by Solav, Dana, Moerman, Kevin M., Jaeger, Aaron M., Genovese, Katia, Herr, Hugh M.

    Published in IEEE access (01-01-2018)
    “…Three-dimensional Digital Image Correlation (3D-DIC) is a non-contact optical-numerical technique for evaluating the dynamic mechanical behavior at the surface…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Multi-material 3-D viscoelastic model of a transtibial residuum from in-vivo indentation and MRI data by Sengeh, David M., Moerman, Kevin M., Petron, Arthur, Herr, Hugh

    “…Although the socket is critical in a prosthetic system for a person with limb amputation, the methods of its design are largely artisanal. A roadblock for a…”
    Get full text
    Journal Article
  4. 4

    Finite element analysis of the performance of additively manufactured scaffolds for scapholunate ligament reconstruction by Perevoshchikova, Nataliya, Moerman, Kevin M, Akhbari, Bardiya, Bindra, Randy, Maharaj, Jayishni N, Lloyd, David G, Gomez Cerezo, Maria, Carr, Amelia, Vaquette, Cedryck, Saxby, David J

    Published in PloS one (19-11-2021)
    “…Rupture of the scapholunate interosseous ligament can cause the dissociation of scaphoid and lunate bones, resulting in impaired wrist function. Current…”
    Get full text
    Journal Article
  5. 5

    A clinical comparison of a digital versus conventional design methodology for transtibial prosthetic interfaces by Lee, Duncan R. C., Yang, Xingbang, Riccio-Ackerman, Francesca, Alemón, Beatriz, Ballesteros-Escamilla, Mariana, Solav, Dana, Lipsitz, Stuart R., Moerman, Kevin M., Meyer, Christina I., Jaeger, Aaron M., Huegel, Joel C., Herr, Hugh M.

    Published in Scientific reports (28-10-2024)
    “…A transtibial prosthetic interface typically comprises a compliant liner and an outer rigid socket. The preponderance of today’s conventional liners are mass…”
    Get full text
    Journal Article
  6. 6

    A MRI-Compatible Combined Mechanical Loading and MR Elastography Setup to Study Deformation-Induced Skeletal Muscle Damage in Rats by Nelissen, Jules L, de Graaf, Larry, Traa, Willeke A, Schreurs, Tom J L, Moerman, Kevin M, Nederveen, Aart J, Sinkus, Ralph, Oomens, Cees W J, Nicolay, Klaas, Strijkers, Gustav J

    Published in PloS one (11-01-2017)
    “…Deformation of skeletal muscle in the proximity of bony structures may lead to deep tissue injury category of pressure ulcers. Changes in mechanical properties…”
    Get full text
    Journal Article
  7. 7

    Biomechanical Characterisation of Thoracic Ascending Aorta with Preserved Pre-Stresses by Parikh, Shaiv, Moerman, Kevin M, Ramaekers, Mitch J F G, Schalla, Simon, Bidar, Elham, Delhaas, Tammo, Reesink, Koen, Huberts, Wouter

    Published in Bioengineering (Basel) (01-07-2023)
    “…Mechanical properties of an aneurysmatic thoracic aorta are potential markers of future growth and remodelling and can help to estimate the risk of rupture…”
    Get full text
    Journal Article
  8. 8
  9. 9

    Journal of Open Source Software (JOSS): design and first-year review by Smith, Arfon M, Niemeyer, Kyle E, Katz, Daniel S, Barba, Lorena A, Githinji, George, Gymrek, Melissa, Huff, Kathryn D, Madan, Christopher R, Mayes, Abigail Cabunoc, Moerman, Kevin M, Prins, Pjotr, Ram, Karthik, Rokem, Ariel, Teal, Tracy K, Guimera, Roman Valls, Vanderplas, Jacob T

    Published in PeerJ Computer Science (12-02-2018)
    “…This article describes the motivation, design, and progress of the Journal of Open Source Software (JOSS). JOSS is a free and open-access journal that…”
    Get full text
    Journal Article
  10. 10

    A Novel Dual Non-Invasive Ventilator Continuous Positive Airway Pressure Non-Aerosolization Circuit for Emergency Use in the COVID-19 Pandemic by Vaughan, Ted J., Kirrane, Frank, Moerman, Kevin M., Cahill, Tara, O’Regan, Anthony, O’Keeffe, Derek T.

    Published in Journal of open hardware (04-09-2020)
    “…The COVID-19 pandemic is a public health emergency of unprecedented scale. The surge in clinical cases of patients with severe respiratory illness has…”
    Get full text
    Journal Article
  11. 11

    Novel hyperelastic models for large volumetric deformations by Moerman, Kevin M., Fereidoonnezhad, Behrooz, McGarry, J. Patrick

    “…Materials such as elastomeric foams, lattices, and cellular solids are capable of undergoing large elastic volume changes. Although many hyperelastic…”
    Get full text
    Journal Article
  12. 12

    A Framework for Measuring the Time-Varying Shape and Full-Field Deformation of Residual Limbs Using 3-D Digital Image Correlation by Solav, Dana, Moerman, Kevin M., Jaeger, Aaron M., Herr, Hugh M.

    “…Effective prosthetic socket design following lower limb amputation depends upon the accurate characterization of the shape of the residual limb as well as its…”
    Get full text
    Journal Article
  13. 13

    Experimental and computational analysis of energy absorption characteristics of three biomimetic lattice structures under compression by Vafaeefar, Mahtab, Moerman, Kevin M, Vaughan, Ted J

    “…The objective of this study is to evaluate the mechanical properties and energy absorption characteristics of the gyroid, dual-lattice and spinodoid…”
    Get full text
    Journal Article
  14. 14

    A morphological, topological and mechanical investigation of gyroid, spinodoid and dual-lattice algorithms as structural models of trabecular bone by Vafaeefar, Mahtab, Moerman, Kevin M., Kavousi, Majid, Vaughan, Ted J.

    “…In this study, we evaluate the performance of three algorithms as computational models of trabecular bone architecture, through systematic evaluation of…”
    Get full text
    Journal Article
  15. 15

    A new compressible hyperelastic model for the multi-axial deformation of blood clot occlusions in vessels by Fereidoonnezhad, Behrooz, Moerman, Kevin M., Johnson, Sarah, McCarthy, Ray, McGarry, Patrick J.

    “…Mechanical thrombectomy can be significantly affected by the mechanical properties of the occluding thrombus. In this study, we provide the first…”
    Get full text
    Journal Article
  16. 16

    Imaging Arterial Fibres Using Diffusion Tensor Imaging—Feasibility Study and Preliminary Results by Flamini, Vittoria, Kerskens, Christian, Moerman, Kevin M, Simms, Ciaran K, Lally, Caitríona

    “…MR diffusion tensor imaging (DTI) was used to analyze the fibrous structure of aortic tissue. A fresh porcine aorta was imaged at 7T using a spin echo sequence…”
    Get full text
    Journal Article
  17. 17

    The anisotropic mechanical behaviour of passive skeletal muscle tissue subjected to large tensile strain by Takaza, Michael, Moerman, Kevin M., Gindre, Juliette, Lyons, Garry, Simms, Ciaran K.

    “…The passive mechanical properties of muscle tissue are important for many biomechanics applications. However, significant gaps remain in our understanding of…”
    Get full text
    Journal Article
  18. 18

    3D Ultrasound Imaging of Residual Limbs With Camera-Based Motion Compensation by Ranger, Bryan J., Feigin, Micha, Zhang, Xiang, Moerman, Kevin M., Herr, Hugh, Anthony, Brian W.

    “…Ultrasound is a cost-effective, readily available, and non-ionizing modality for musculoskeletal imaging. Though some research groups have pursued methods that…”
    Get full text
    Journal Article
  19. 19

    Constitutive parameter identification of transtibial residual limb soft tissue using ultrasound indentation and shear wave elastography by Ranger, Bryan J, Moerman, Kevin M, Anthony, Brian W, Herr, Hugh M

    “…Finite element analysis (FEA) can be used to evaluate applied interface pressures and internal tissue strains for computational prosthetic socket design. This…”
    Get full text
    Journal Article
  20. 20

    3D Ultrasound Shear Wave Elastography for Musculoskeletal Tissue Assessment Under Compressive Load: A Feasibility Study by Ranger, Bryan J., Moerman, Kevin M., Feigin, Micha, Herr, Hugh M., Anthony, Brian W.

    Published in Ultrasonic imaging (01-09-2024)
    “…Given its real-time capability to quantify mechanical tissue properties, ultrasound shear wave elastography holds significant promise in clinical…”
    Get full text
    Journal Article