Search Results - "Mock, RC"

  • Showing 1 - 14 results of 14
Refine Results
  1. 1
  2. 2

    Z -Pinch-Generated X Rays Demonstrate Potential for Indirect-Drive ICF Experiments by Sanford, T. W. L., Olson, R. E., Bowers, R. L., Chandler, G. A., Derzon, M. S., Hebron, D. E., Leeper, R. J., Mock, R. C., Nash, T. J., Peterson, D. L., Ruggles, L. E., Simpson, W. W., Struve, K. W., Vesey, R. A.

    Published in Physical review letters (27-12-1999)
    “…Hohlraums measuring 6 mm in diameter by 7 mm in height have been heated by x rays from a Z pinch. Over the measured x-ray input powers P of 0.7 to 13 TW, the…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Wire number doubling in high-wire-number regime increases Z-accelerator X-ray power by Sanford, T.W.L., Spielman, R.B., Allshouse, G.O., Chandler, G.A., Fehl, D.L., Stygar, W.A., Struve, K.W., Deeney, C., Nash, T.J., Seamen, J.F., Mock, R.C., Gilliland, T.L., McGurn, J.S., Jobe, D.O.

    Published in IEEE transactions on plasma science (01-08-1998)
    “…Doubling the number of tungsten wires from 120 to 240, keeping the mass fixed, increased the radiated X-ray power relative to the electrical power at the…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Azimuthal structure in wire-array Z pinch experiments by Sanford, T.W.L., Roderick, N.F., Mock, R.C., Struve, K.W., Peterson, D.L.

    Published in IEEE transactions on plasma science (01-04-2002)
    “…Nested wire-array loads on Z with a high degree of azimuthal symmetry in the outside current-return-shell (which surrounds a z pinch) exhibit a 6/spl plusmn/2…”
    Get full text
    Journal Article
  7. 7

    An intense large-volume uniform source of bremsstrahlung for pulsed gamma ray simulation by Sanford, T.W.L., Mock, R.C.

    Published in IEEE transactions on nuclear science (01-12-1992)
    “…The intense radiation fields generated with useful uniformity over large volumes using the novel compound-lens diode on Hermes III are characterized. The…”
    Get full text
    Journal Article Conference Proceeding
  8. 8

    Dose-rate field of the HERMES III flash X-ray source by Sanford, T.W.L., Halbleib, J.A., Mock, R.C.

    Published in IEEE transactions on nuclear science (01-12-1990)
    “…Measurements show that the HERMES III flash X-ray source produces a peak dose-rate radiation field of (5+or-0.5)*10/sup 12/ rad(Si)/s over a useful area of…”
    Get full text
    Journal Article Conference Proceeding
  9. 9

    Carbon dioxide induces endotrophic germ tube formation in Candida albicans by Mock, R C, Pollack, J H, Hashimoto, T

    Published in Canadian journal of microbiology (01-04-1990)
    “…Candida albicans formed germ tubes when exposed to air containing 5 to 15% carbon dioxide (CO2). The CO2-mediated germ tube formation occurred optimally at 37…”
    Get more information
    Journal Article
  10. 10
  11. 11
  12. 12

    Wire-array holder critical in high wire-number z-pinch implosions by Sanford, T.W.L., Mock, R.C., Gilliland, T.L., Seamen, J.F., Leeper, R.J., Watt, R.G., Chrien, R.E., Idzorek, G.C., Peterson, D.L., Duselis, P.U.

    “…The quality of high wire-number z-pinch implosions on Z using a dynamic-hohlraum configuration is significantly affected by the method of holding the wires…”
    Get full text
    Conference Proceeding
  13. 13
  14. 14

    Compound-lens injector for a 19-MeV, 700-kA electron beam by Sanford, T.W.L., Poukey, J.W., Halbleib, J.A., Mock, R.C.

    “…A robust injector capable of controlling the radius and angle of incidence of the intense, pulsed, annular electron beam extracted from the HERMES-III…”
    Get full text
    Conference Proceeding