Effectiveness of a continuous patient position monitoring system in improving hospital turn protocol compliance in an ICU: A multiphase multisite study in India

Purpose Hospital-acquired pressure ulcers are a significant cause of morbidity and consume considerable financial resources. Turn protocols (repositioning patients at regular intervals) are utilized to reduce incidence of pressure ulcers. Adherence to turn protocols is particularly challenging for n...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the Intensive Care Society Vol. 20; no. 4; pp. 309 - 315
Main Authors: Renganathan, BS, Nagaiyan, Sridhar, Preejith, SP, Gopal, Shameer, Mitra, Susovan, Sivaprakasam, Mohanasankar
Format: Journal Article
Language:English
Published: London, England SAGE Publications 01-11-2019
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose Hospital-acquired pressure ulcers are a significant cause of morbidity and consume considerable financial resources. Turn protocols (repositioning patients at regular intervals) are utilized to reduce incidence of pressure ulcers. Adherence to turn protocols is particularly challenging for nursing teams, given the high number of interventions in intensive care unit, and lack of widely available tools to monitor patient position and generate alerts. We decided to develop and evaluate usefulness of a continuous patient position monitoring system to assist nurses in improving turn protocol compliance. Methods We conducted a prospective, non-randomized, multiphase, multicentre trial. In Phase I (control group), the function of the device was not revealed to nurses so as to observe their baseline adherence to turn protocol, while Phase II (intervention group) used continuous patient position monitoring system to generate alerts, when non-compliant with the turn protocol. All consecutive patients admitted to one of the two intensive care units during the study period were screened for enrolment. Patients at risk of acquiring pressure ulcers (Braden score < 18) were considered for the study (Phase I (N = 22), Phase II (N = 25)). Results We analysed over 1450 h of patient position data collected from 40 patients (Phase I (N = 20), Phase II (N = 20)). Turn protocol compliance was significantly higher in Phase II (80.15 ± 8.97%) compared to the Phase I (24.36 ± 12.67%); p < 0.001. Conclusion Using a continuous patient position monitoring system to provide alerts significantly improved compliance with hospital turn protocol. Nurses found the system to be useful in providing automated turn reminders and prioritising tasks.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1751-1437
2057-360X
DOI:10.1177/1751143718804682