Search Results - "Misiakos, K."

Refine Results
  1. 1

    Point-of-Need bioanalytics based on planar optical interferometry by Makarona, E, Petrou, P, Kakabakos, S, Misiakos, K, Raptis, I

    Published in Biotechnology advances (01-05-2016)
    “…This review brings about a comprehensive presentation of the research on interferometric transducers, which have emerged as extremely promising candidates for…”
    Get full text
    Journal Article
  2. 2

    All-silicon monolithic Mach-Zehnder interferometer as a refractive index and bio-chemical sensor by Misiakos, K, Raptis, I, Makarona, E, Botsialas, A, Salapatas, A, Oikonomou, P, Psarouli, A, Petrou, P S, Kakabakos, S E, Tukkiniemi, Kari, Sopanen, M, Jobst, G

    Published in Optics express (03-11-2014)
    “…A complete Mach-Zehnder interferometer monolithically integrated on silicon is presented and employed as a refractive index and bio-chemical sensor. The device…”
    Get full text
    Journal Article
  3. 3

    Label-free detection of the IL-6 and IL-8 interleukines through monolithic silicon photonic chips and simultaneous dual polarization optics by Anastasopoulou, M., Malainou, A., Salapatas, A., Chronis, N., Raptis, I., Misiakos, K.

    Published in Sensors and actuators. B, Chemical (01-03-2018)
    “…•A Si microphotonic chip with ten monolithically integrated broad-band Mach-Zehnder interferometers and an equal number of light sources.•The Si microphotonic…”
    Get full text
    Journal Article
  4. 4

    Broad-band Mach-Zehnder interferometers as high performance refractive index sensors: theory and monolithic implementation by Misiakos, K, Raptis, I, Salapatas, A, Makarona, E, Botsialas, A, Hoekman, M, Stoffer, R, Jobst, G

    Published in Optics express (21-04-2014)
    “…Broad-band Mach-Zehnder interferometry is analytically described and experimentally demonstrated as an analytical tool capable of high accuracy refractive…”
    Get full text
    Journal Article
  5. 5

    A label-free flow-through immunosensor for determination of total- and free-PSA in human serum samples based on white-light reflectance spectroscopy by Koukouvinos, G., Petrou, P.S., Misiakos, K., Drygiannakis, D., Raptis, I., Goustouridis, D., Kakabakos, S.E.

    Published in Sensors and actuators. B, Chemical (31-03-2015)
    “…•White light reflectance spectroscopy for the real-time monitoring of bioreactions.•Label-free determination of total-and free-PSA in human serum…”
    Get full text
    Journal Article
  6. 6

    Monolithically integrated broad-band Mach-Zehnder interferometers for highly sensitive label-free detection of biomolecules through dual polarization optics by Psarouli, A., Salapatas, A., Botsialas, A., Petrou, P. S., Raptis, I., Makarona, E., Jobst, G., Tukkiniemi, K., Sopanen, M., Stoffer, R., Kakabakos, S. E., Misiakos, K.

    Published in Scientific reports (02-12-2015)
    “…Protein detection and characterization based on Broad-band Mach-Zehnder Interferometry is analytically outlined and demonstrated through a monolithic silicon…”
    Get full text
    Journal Article
  7. 7

    Molecular film growth monitoring via reflection microscopy on periodically patterned substrates by Archontas, I, Salapatas, A, Misiakos, K

    Published in Optics express (25-02-2013)
    “…An optical method is presented for in the situ monitoring of biomolecular films via reflection microscopy on patterned substrates. The method is based on…”
    Get full text
    Journal Article
  8. 8

    Scaling of magnetotransport properties in granular Co(c=0.8)Bi(1−c) thin films by Speliotis, Th, Athanasopoulos, P., Melitsiotis, A., Papaioannou, V.M., Travlos, A., Misiakos, K., Christides, C.

    Published in Applied surface science (15-04-2015)
    “…•Granular Bi0.2Co0.8 films were prepared by magnetron sputtering.•Exhibit a quasi-linear temperature dependence of ρ(T) between 50 and 200K, whereas a…”
    Get full text
    Journal Article
  9. 9

    Biomolecular layer thickness evaluation using White Light Reflectance Spectroscopy by Kitsara, M., Petrou, P., Kontziampasis, D., Misiakos, K., Makarona, E., Raptis, I., Beltsios, K.

    Published in Microelectronic engineering (01-05-2010)
    “…A White Light Reflectance Spectroscopy (WLRS) methodology is applied in the evaluation of the effectiveness of biomolecules immobilization onto solid surfaces…”
    Get full text
    Journal Article Conference Proceeding
  10. 10

    Study of base series resistance losses in single and double emitter silicon solar cells through simulations and experiments by Kotsovos, K., Misiakos, K.

    Published in Progress in photovoltaics (01-11-2008)
    “…This work focuses on base series resistance influence on the performance of single and double emitter rear point contact silicon solar cells. This study is…”
    Get full text
    Journal Article
  11. 11

    Selective plasma-induced deposition of fluorocarbon films on metal surfaces for actuation in microfluidics by Bayiati, P., Tserepi, A., Gogolides, E., Misiakos, K.

    “…The present work focuses on the selective deposition of fluorocarbon (FC) films on metal surfaces, aluminum in specific, over SiO 2 surfaces, in order to…”
    Get full text
    Conference Proceeding Journal Article
  12. 12

    Capillary-based immunoassays, immunosensors and DNA sensors – steps towards integration and multi-analysis by Mastichiadis, C., Niotis, A.E., Petrou, P.S., Kakabakos, S.E., Misiakos, K.

    “…This review deals with immunoassays, immunosensors and DNA sensors based on capillaries. The one-dimensional cylindrical geometry of capillaries offers several…”
    Get full text
    Journal Article
  13. 13

    Monolithic silicon optocoupler engineering based on tapered waveguides by Misiakos, K., Makarona, E., Kitsara, M., Raptis, I.

    Published in Microelectronic engineering (01-05-2008)
    “…The increased need for further miniaturization of biosensors poses an increased need for the integrated optical fibers to bend, fold or change direction within…”
    Get full text
    Journal Article Conference Proceeding
  14. 14

    Electron beam patterning of biomolecules by Glezos, N, Misiakos, K, Kakabakos, S, Petrou, P, Terzoudi, G

    Published in Biosensors & bioelectronics (01-04-2002)
    “…The patterning of biomolecules on semiconducting surfaces is of central importance in the fabrication of novel biodevices. In the process of patterning, it is…”
    Get full text
    Journal Article Conference Proceeding
  15. 15

    Base limited carrier transport and performance of double junction rear point contact silicon solar cells by Kotsovos, K., Misiakos, K.

    Published in Solar energy materials and solar cells (15-05-2003)
    “…Rear point contact (locally diffused) solar cells with double collecting p/n junctions are investigated through numerical three-dimensional simulation and…”
    Get full text
    Journal Article
  16. 16

    Multi-analyte capillary immunosensor for the determination of hormones in human serum samples by Petrou, P.S., Kakabakos, S.E., Christofidis, I., Argitis, P., Misiakos, K.

    Published in Biosensors & bioelectronics (01-04-2002)
    “…In this work we present the development of a multi-analyte immunosensor for the determination of follitropin, human chorionic gonadotropin and prolactin in…”
    Get full text
    Journal Article Conference Proceeding
  17. 17

    Biofluid transport on hydrophobic plasma-deposited fluorocarbon films by Bayiati, P., Tserepi, A., Petrou, P.S., Misiakos, K., Kakabakos, S.E., Gogolides, E., Cardinaud, C.

    Published in Microelectronic engineering (01-05-2007)
    “…The present work focuses on the use of plasma-deposited hydrophobic fluorocarbon films for electrowetting-based bio-fluid transport in microfluidic devices…”
    Get full text
    Journal Article Conference Proceeding
  18. 18

    Protein patterning by micromachined silicon embossing on polymer surfaces by Goustouridis, D., Misiakos, K., Petrou, P. S., Kakabakos, S. E.

    Published in Applied physics letters (27-12-2004)
    “…An automated method for creating micron-sized patterns of different proteins is described. Unlike other methods, the process requires no masks, photochemichal…”
    Get full text
    Journal Article
  19. 19

    A multi-band capillary immunosensor by Misiakos, K., Kakabakos, S.E.

    Published in Biosensors & bioelectronics (01-10-1998)
    “…In the present work we propose a new optical immunosensor based on capillary geometry and capable of multianalyte determinations. The device is made of a…”
    Get full text
    Journal Article
  20. 20

    A readout system for X-ray powder crystallography by Loukas, D., Haralabidis, N., Pavlidis, A., Karvelas, E., Psycharis a, K. Misiakos, V., Mousa, J., Dre, Ch

    “…A system for capturing and processing data, from radiation detectors, in the field of X-ray crystallography has been developed. The system includes a…”
    Get full text
    Journal Article