Search Results - "Millan, Maria S"

Refine Results
  1. 1

    Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients by Armengol, Jesús, Garzón, Nuria, Vega, Fidel, Altemir, Irene, Millán, Maria S.

    Published in Biomedical optics express (01-05-2020)
    “…This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their…”
    Get full text
    Journal Article
  2. 2

    Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design by Vega, Fidel, Millán, Maria S, Garzón, Nuria, Altemir, Irene, Poyales, Francisco, Larrosa, Jose Manuel

    Published in Biomedical optics express (01-10-2018)
    “…The optical quality of a set of IOLs (modeling set: one monofocal and two bifocals) was assessed through focus by the area under the modulation transfer…”
    Get full text
    Journal Article Publication
  3. 3

    Spatio-chromatic vision with multifocal diffractive intraocular lens by Millan, Maria S, Clavé, Laura, Torrents, Aurora, Armengol, Jesús, Vega, Fidel

    Published in Eye and vision (Novato, Calif.) (01-08-2023)
    “…This study aims to detect alterations in the spatio-chromatic pseudophakic vision produced by multifocal diffractive intraocular lenses (IOLs) and provides a…”
    Get full text
    Journal Article
  4. 4

    Editorial to the Special Issue on “Ocular Imaging for Eye Care” by Millan, Maria S., Marrugo, Andres G.

    Published in Photonics (01-07-2022)
    “…The need for fast, inexpensive, and robust medical technology is now more crucial than ever [...]…”
    Get full text
    Journal Article
  5. 5

    Retinal Vessel Local Tortuosity under a Macula-to-Optic Disc Central-Framing Change by Ramírez, Natalia, Ralló, Miquel, Millan, Maria S

    Published in Diagnostics (Basel) (01-03-2023)
    “…Some ocular and cardiovascular diseases can be detected through the increased tortuosity of retinal blood vessels. Objective tortuosity measures can be…”
    Get full text
    Journal Article
  6. 6

    Defocus correction in the optical system of the eye: unconventional degrees of freedom by Alba-Bueno, Francisco, Millan, Maria S

    Published in Journal of Biomedical Optics (01-01-2011)
    “…Despite the interest in developing improved formulas for intraocular lens power calculation, there are several sources of uncertainty that may well give rise…”
    Get full text
    Journal Article
  7. 7

    Chromatic changes in vision with diffractive ophthalmic optics by Clavé, Laura, Faria-Ribeiro, Miguel, Millan, Maria S

    Published in Optics express (11-03-2024)
    “…Diffractive optics is a valuable technique for designing presbyopia-correcting lenses, but its effectiveness is wavelength-dependent. This study investigates…”
    Get full text
    Journal Article
  8. 8

    Extended depth of focus intraocular lens: Chromatic performance by Millán, Maria S, Vega, Fidel

    Published in Biomedical optics express (01-09-2017)
    “…We describe a first-and-second-diffractive-order intraocular lens ((1 ,2 )DIOL) within the class of hybrid refractive-diffractive designs for intraocular…”
    Get full text
    Journal Article Publication
  9. 9

    Optical Techniques for Information Security by Matoba, Osamu, Nomura, Takanori, Perez-Cabre, Elisabet, Millan, MarÍa S., Javidi, Bahram

    Published in Proceedings of the IEEE (01-06-2009)
    “…This paper presents an overview of the potential of free space optical technology in information security, encryption, and authentication. Optical waveform…”
    Get full text
    Journal Article Publication
  10. 10

    Corneal endothelium assessment in specular microscopy images with Fuchs' dystrophy via deep regression of signed distance maps by Sierra, Juan S, Pineda, Jesus, Rueda, Daniela, Tello, Alejandro, Prada, Angélica M, Galvis, Virgilio, Volpe, Giovanni, Millan, Maria S, Romero, Lenny A, Marrugo, Andres G

    Published in Biomedical optics express (01-01-2023)
    “…Specular microscopy assessment of the human corneal endothelium (CE) in Fuchs' dystrophy is challenging due to the presence of dark image regions called…”
    Get full text
    Journal Article
  11. 11

    Comparison of visual and optical quality of monofocal versus multifocal intraocular lenses by Altemir-Gomez, Irene, Millan, Maria S, Vega, Fidel, Bartol-Puyal, Francisco, Gimenez-Calvo, Galadriel, Larrosa, Jose M, Polo, Vicente, Pablo, Luis E, Garcia-Martin, Elena

    Published in European journal of ophthalmology (01-03-2020)
    “…Objective: To compare visual quality in patients implanted with Tecnis® monofocal (ZCB00) and multifocal (ZMB00) intraocular lenses taking into account their…”
    Get full text
    Journal Article Publication
  12. 12

    Optical design and performance of a trifocal sinusoidal diffractive intraocular lens by Vega, Fidel, Valentino, Maite, Rigato, Franco, Millán, María S.

    Published in Biomedical optics express (01-06-2021)
    “…Two theoretical sinusoidal diffractive profile models to build up a trifocal intraocular lens (IOL) are analysed. Topographic features of the diffractive zones…”
    Get full text
    Journal Article
  13. 13

    Do diffractive intraocular lenses break the beneficial interaction between chromatic and monochromatic aberrations in the eye? by Clavé, Laura, Millan, Maria S.

    Published in Biomedical optics express (01-12-2024)
    “…This study investigates whether a diffractive presbyopia-correcting multifocal intraocular lens disrupts the favorable interaction between chromatic and…”
    Get full text
    Journal Article
  14. 14

    Double Image Encryption System Using a Nonlinear Joint Transform Correlator in the Fourier Domain by Perez, Ronal A, Pérez-Cabré, Elisabet, Vilardy, Juan M, Millán, María S, Torres, Cesar O

    Published in Sensors (Basel, Switzerland) (02-02-2023)
    “…In this work, we present a new nonlinear joint transform correlator (JTC) architecture in the Fourier domain (FD) for the encryption and decryption of two…”
    Get full text
    Journal Article
  15. 15

    Nonlinear Encryption for Multiple Images Based on a Joint Transform Correlator and the Gyrator Transform by Perez, Ronal A, Vilardy, Juan M, Pérez-Cabré, Elisabet, Millán, María S, Torres, Cesar O

    Published in Sensors (Basel, Switzerland) (03-02-2023)
    “…A novel nonlinear encryption-decryption system based on a joint transform correlator (JTC) and the Gyrator transform (GT) for the simultaneous encryption and…”
    Get full text
    Journal Article
  16. 16

    Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses by Vega, Fidel, Alba-Bueno, Francisco, Millán, María S, Varón, Consuelo, Gil, Miguel A, Buil, Jose A

    “…To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). Three diffractive…”
    Get full text
    Journal Article Publication
  17. 17

    Tolerance to residual astigmatism of an isofocal intraocular lens by Pérez-Sanz, Lidia, Vega, Fidel, Azor-Morón, Juan A., Cuellar, Fátima, Millán, María S., Garzón, Nuria

    “…Purpose To evaluate the impact of residual astigmatism on the optical and visual performance of an enhanced-monofocal isofocal intraocular lens (EM Isopure,…”
    Get full text
    Journal Article
  18. 18

    Optical and Clinical Outcomes of an Enhanced Monofocal Intraocular Lens for High Hyperopia by Fernández-Vega-Cueto, Luis, Vega, Fidel, Guerra-Velasco, Raquel, Millán, María S, Madrid-Costa, David, Alfonso, José F

    Published in Journal of refractive surgery (1995) (01-09-2022)
    “…To evaluate the optical and clinical performance of an enhanced monofocal intraocular lens (IOL) (TECNIS Eyhance ICB00; Johnson & Johnson Vision) in patients…”
    Get more information
    Journal Article
  19. 19

    Optical and Clinical Outcomes of an Extended Range of Vision Intraocular Lens by Fernández-Vega-Cueto, Luis, Madrid-Costa, David, Alfonso-Bartolozzi, Belén, Vega, Fidel, Millán, María S, Alfonso, José F

    Published in Journal of refractive surgery (1995) (01-03-2022)
    “…To assess the in vitro optical quality and halo formation of the AcrySof IQ Vivity intraocular lens (IOL) (Alcon Laboratories, Inc) and to evaluate the…”
    Get more information
    Journal Article
  20. 20

    Comparison of visual performance between two aspheric monofocal intraocular lens models by Poyales, Francisco, Garzón, Nuria, Rico, Laura, Zhou, Ying, Millán, María S, Vega, Fidel

    “…It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These…”
    Get full text
    Journal Article