Search Results - "Mihalczo, J."
-
1
Subcritical reactivity monitoring in accelerator driven systems
Published in Annals of nuclear energy (01-10-2001)“…In this paper, an absolute measurements technique for the subcriticality determination is presented. The development of accelerator driven systems (ADS)…”
Get full text
Journal Article -
2
Physical description of nuclear materials identification system (NMIS) signatures
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2000)“…This paper describes all time and frequency analysis parameters measured with a new correlation processor (capability up to 1 GHz sampling rates and up to five…”
Get full text
Journal Article -
3
NMIS plus gamma spectroscopy for attributes of HEU, PU and HE detection
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (2004)“…A combined nuclear materials identification system–gamma ray spectrometry system can be used passively to obtain the following attributes of Pu: presence,…”
Get full text
Journal Article -
4
Fast coincidence counting with active inspection systems
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-12-2005)“…This paper describes 2nd and 3rd order time coincidence distributions measurements with a GHz processor that synchronously samples 5 or 10 channels of data…”
Get full text
Journal Article -
5
Delayed critical ORNL unreflected uranium (93.20) metal sphere and the pure unreflected uranium (93.80) sphere critical mass
Published in Annals of nuclear energy (01-03-2002)“…A spherical critical assembly of unreflected and unmoderated uranium (93.20 wt.% 235U) metal was assembled at the Oak Ridge Critical Experiments Facility in…”
Get full text
Journal Article -
6
MCNP-DSP: A neutron and gamma ray Monte carlo calculation of source-driven noise-measured parameters
Published in Annals of nuclear energy (1996)“…The 252Cf-source-driven noise analysis measurement method was developed to determine the subcriticality and other properties of configurations of fissile…”
Get full text
Journal Article -
7
Stochastic transport theory of neutron and photon coupled fields: neutron and photon counting statistics in nuclear assemblies
Published in Annals of nuclear energy (2000)“…The behavior of neutrons and gamma rays in a nuclear reactor or configuration of fissile material can be represented as a stochastic process. The observation…”
Get full text
Journal Article -
8
A novel method for determining pulse counting circuitry dead time using the Nuclear Weapons Inspection System
Published in IEEE transactions on nuclear science (01-06-1998)“…A novel method for measuring dead time in nuclear pulse processing circuitry has been developed using the autocorrelation measurement capability of the Nuclear…”
Get full text
Journal Article -
9
Portable fast-neutron radiography with the nuclear materials identification system for fissile material transfers
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-08-2007)“…The nuclear materials identification system (NMIS) has historically been used with a 252Cf source for bulk interrogation of highly enriched uranium and…”
Get full text
Journal Article -
10
High-efficiency scintillation detector for thermal and high-energy neutrons and gamma radiation
Published in IEEE Transactions on Nuclear Science (01-02-1988)“…Subcriticality experiments require high-efficiency radiation detectors that are sensitive to neutrons (thermal and fast) over a wide energy range and to gamma…”
Get full text
Journal Article Conference Proceeding -
11
Validation of the Monte Carlo code MCNP-DSP
Published in Annals of nuclear energy (1997)“…Several calculations were performed to validate MCNP-DSP, which is a Monte Carlo code that calculates all the time and frequency analysis parameters associated…”
Get full text
Journal Article -
12
A portable measurement system for subcriticality measurements by the CF-source-driven neutron noise analysis method
Published in IEEE transactions on nuclear science (01-02-1988)“…A description is given of a portable measurement system consisting of a personal computer used as a Fourier analyzer and three detection channels (with…”
Get full text
Journal Article Conference Proceeding -
13
An alpha particle detector for a portable neutron generator for the Nuclear Materials Identification System (NMIS)
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-12-2005)“…A recoil alpha particle detector has been developed for use in a portable neutron generator. The associated particle sealed tube neutron generator (APSTNG)…”
Get full text
Journal Article -
14
Characterization of an Associated Particle Neutron Generator With ZnO:Ga Alpha-Detector and Active Focusing
Published in IEEE transactions on nuclear science (01-06-2009)“…A deuterium-tritium (DT) associated particle neutron generator (APNG) with active focusing has been operated using an alpha particle detector made of a ZnO:Ga…”
Get full text
Journal Article -
15
Utilization of actively-induced, prompt radiation emission for nonproliferation applications
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-08-2007)“…The pulsed photonuclear assessment (PPA) technique, which has demonstrated the ability to detect shielded nuclear material, is based on utilizing delayed…”
Get full text
Journal Article Conference Proceeding -
16
Monte Carlo analysis of neutron detection with a BaF(2) scintillation detector
Published in IEEE transactions on nuclear science (01-06-2004)“…This work presents the results of investigations aimed at simulating the response of a barium fluoride (BaF(2)) detector to neutrons and photons. The…”
Get full text
Journal Article -
17
Monte Carlo analysis of neutron detection with a BaF sub(2) scintillation detector
Published in IEEE transactions on nuclear science (01-01-2004)“…This work presents the results of investigations aimed at simulating the response of a barium fluoride (BaF sub(2)) detector to neutrons and photons. The…”
Get full text
Journal Article -
18
In-the-flash pulse shape discrimination with liquid scintillators
Published in 2008 IEEE Nuclear Science Symposium Conference Record (01-10-2008)“…Single neutron and gamma charge pulses were captured using a fast ADC. These data were used to populate simulated 5-µs active interrogation flash events…”
Get full text
Conference Proceeding -
19
Detection of Special Nuclear Material by means of promptly emitted radiation following photonuclear stimulation
Published in 2007 IEEE Nuclear Science Symposium Conference Record (01-10-2007)“…Techniques have been developed to exploit abundant prompt emissions from photonuclear reactions for the identification of special nuclear material (SNM). These…”
Get full text
Conference Proceeding -
20
Plasma Confinement Studies in the ISX- A Tokamak
Published in Physical review letters (05-03-1979)“…Gross-energy-confinement times in the ISX-A (Impurity Study Experiment) tokamak exceeded predictions of the usual empirical scaling relations. This performance…”
Get full text
Journal Article