Search Results - "Meuris, Aline"
-
1
Characterization of polarization phenomenon in Al-Schottky CdTe detectors using a spectroscopic analysis method
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-10-2011)“…CdTe radiation detectors equipped with Schottky contacts are known to show spectral response degradation over time under biasing. Nevertheless, they can be…”
Get full text
Journal Article -
2
Micro Hard-X Ray Camera: From Caliste 64 to Caliste 256
Published in IEEE transactions on nuclear science (01-08-2009)“…Caliste project aims at hybridizing 1 cm 2 Cd(Zn)Te detectors with low noise front-end electronics, in a single component standing in a 1 times 1times 2 cm 3…”
Get full text
Journal Article -
3
Development and Characterization of New 256 \,\times\,256 Pixel DEPFET Detectors for X-Ray Astronomy
Published in IEEE transactions on nuclear science (01-06-2011)“…DEPFET detectors are silicon (Si) active pixel sensors designed and manufactured in the Max-Planck-Institut semiconductor lab. Their high spatial resolution…”
Get full text
Journal Article -
4
The enhanced X-ray Timing and Polarimetry mission—eXTP
Published in Science China. Physics, mechanics & astronomy (01-02-2019)“…In this paper we present the enhanced X-ray Timing and Polarimetry mission—eXTP. eXTP is a space science mission designed to study fundamental physics under…”
Get full text
Journal Article -
5
Characterization of the focal plane of the microchannel X-ray telescope at the metrology beamline of SOLEIL synchrotron for the space astronomy mission SVOM
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2023)“…The Microchannel X-Ray Telescope is one of the four instruments of the SVOM Sino-French space mission to observe the afterglow of gamma-ray bursts in the…”
Get full text
Journal Article -
6
Second generation of portable gamma camera based on Caliste CdTe hybrid technology
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-12-2018)“…In the framework of a national funded program for nuclear safety, a first prototype of portable gamma camera was built and tested. It integrates a Caliste-HD…”
Get full text
Journal Article -
7
Characterization of the detection chain of the Micro-channel X-ray Telescope
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-09-2020)“…This paper describes the first performance tests and characterization of the detection chain of the Micro-channel X-ray Telescope (MXT), one of the instruments…”
Get full text
Journal Article -
8
Low Energy Characterization of Caliste HD, a Fine Pitch CdTe-Based Imaging Spectrometer
Published in IEEE transactions on nuclear science (01-10-2013)“…Caliste HD is a recently developed micro-camera designed for X and gamma-ray astronomy, based on a 1×1 cm 2 CdTe Schottky pixelated detector. Its entire…”
Get full text
Journal Article -
9
Development and Characterization of New 256[Formula Omitted]256 Pixel DEPFET Detectors for X-Ray Astronomy
Published in IEEE transactions on nuclear science (01-06-2011)“…DEPFET detectors are silicon (Si) active pixel sensors designed and manufactured in the Max-Planck-Institut semiconductor lab. Their high spatial resolution…”
Get full text
Journal Article -
10
Semiconductor Detector Developments for High Energy Space Astronomy
Published 06-06-2014“…The rise of high energy astrophysics and solar physics in the 20th century is linked to the development of space telescopes; since the 1960s they have given…”
Get full text
Journal Article -
11
Caliste HD: A new fine pitch Cd(Zn)Te imaging spectrometer from 2 keV up to 1 MeV
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…Caliste HD is the last member of the Caliste family of Cd(Zn)Te micro-cameras for space applications. This hybrid component is made of the assembly of one 16 ×…”
Get full text
Conference Proceeding -
12
IDeF-X ECLAIRs: A CMOS ASIC for the Readout of CdTe and CdZnTe Detectors for High Resolution Spectroscopy
Published in IEEE transactions on nuclear science (01-08-2009)“…The very last member of the IDeF-X ASIC family is presented: IDeF-X ECLAIRs is a 32-channel front end ASIC designed for the readout of Cadmium Telluride (CdTe)…”
Get full text
Journal Article -
13
Low energy characterization of Caliste HD, a CdTe based imaging spectrometer
Published in 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) (01-10-2012)“…Caliste HD is a recently developed micro-camera designed for X and gamma-rays astronomy, based on a 1×1 cm 2 CdTe Schottky pixelated detector. Its entire…”
Get full text
Conference Proceeding -
14
IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications
Published 03-02-2021“…IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to…”
Get full text
Journal Article -
15
The TRILL project: increasing the technological readiness of Laue lenses
Published 20-09-2023“…Proceedings Volume 12181, Space Telescopes and Instrumentation 2022: Ultraviolet to Gamma Ray; 121812K (2022) Hard X-/soft Gamma-ray astronomy (> 100 keV) is a…”
Get full text
Journal Article -
16
The Wide Field Monitor (WFM) of the China-Europe eXTP (enhanced X-ray Timing and Polarimetry) mission
Published 05-11-2024“…Proc. of SPIE 2024 Vol. 13093 130931Y The eXTP mission is a major project of the Chinese Academy of Sciences (CAS), with a large involvement of Europe. Its…”
Get full text
Journal Article -
17
STROBE-X High Energy Modular Array (HEMA)
Published 10-10-2024“…J. Astron. Telesc. Instrum. Syst. 10(4) 042503 (26 October 2024) The High Energy Modular Array (HEMA) is one of three instruments that compose the STROBE-X…”
Get full text
Journal Article -
18
First Characterization of the Focal Plane of the Micro-Channel X-Ray Telescope on board the SVOM Mission and Preparation of Radiation Tests to Predict its Performances in Low-Earth Orbit
Published in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC) (01-11-2018)“…This paper describes the simulated in-orbit environment and the first on-ground experimental characterisation of the focal plane of the Micro-channel X-ray…”
Get full text
Conference Proceeding -
19
Development and characterization of new 256 × 256 pixel DEPFET detectors for X-ray astronomy
Published in IEEE Nuclear Science Symposuim & Medical Imaging Conference (01-10-2010)“…DEPFET detectors are silicon active pixel sensors for X-ray imaging spectroscopy. They will be used for the MIXS instrument of BepiColombo planetary mission…”
Get full text
Conference Proceeding -
20
Second generation of portable gamma camera based on Caliste CdTe hybrid technology
Published 28-01-2020“…In the framework of a national funded program for nuclear safety, a first prototype of portable gamma camera was built and tested. It integrates a Caliste-HD…”
Get full text
Journal Article