Search Results - "Mehler, D."
-
1
Neurofeedback: One of today's techniques in psychiatry?
Published in Encéphale (01-04-2017)“…Neurofeedback is a technique that aims to teach a subject to regulate a brain parameter measured by a technical interface to modulate his/her related brain and…”
Get more information
Journal Article -
2
Biomechanical evaluation of a new treatment method for distal tibia fractures
Published in Computer methods in biomechanics and biomedical engineering (01-01-2015)Get full text
Journal Article -
3
Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula
Published in Archives of orthopaedic and trauma surgery (01-12-2004)“…Studies of hip arthroplasty have dealt mainly with total endoprosthesis, while tribology measurement values of hemi-endoprosthetic implants are rare. The small…”
Get full text
Journal Article -
4
Exceptional Convergence on the Macroevolutionary Landscape in Island Lizard Radiations
Published in Science (American Association for the Advancement of Science) (19-07-2013)“…G. G. Simpson, one of the chief architects of evolutionary biology's modern synthesis, proposed that diversification occurs on a macroevolutionary adaptive…”
Get full text
Journal Article -
5
Influence of implant and screw type on local bone strain field: a preliminary study
Published in Computer methods in biomechanics and biomedical engineering (01-05-2019)Get full text
Journal Article -
6
ON-X bileaflet valve in aortic position--early experience shows an improved hemodynamic profile
Published in The Thoracic and cardiovascular surgeon (01-10-1998)“…Despite considerable progress during the last decades, mechanical heart valves still have significant disadvantages in performance compared to native valves…”
Get more information
Journal Article -
7
Friction in hip hemiendoprostheses. Review of literature and own model using cadaveric acetabula
Published in Hip international (01-04-2002)“…The science of tribology concerning hip arthroplasty has mainly dealt with total endoprosthesis, whereas measurement values of hemiendoprosthetic implants are…”
Get full text
Journal Article -
8
Shaft lengthening in hip replacement: experimental studies on bending stiffness
Published in Der Unfallchirurg (01-08-2006)“…Cortical atrophy of the proximal femur can be seen after wearing a total hip prosthesis for several years because loads are borne distally at the prosthesis…”
Get full text
Journal Article -
9
Locking plates for corrective Osteotomy of malunited dorsally tilted distal radial fractures: a biomechanical study
Published in Journal of hand surgery, British volume (01-10-2006)“…The purpose of the study was to compare the biomechanical properties of five different palmar fixation plate designs in a distal radius osteotomy cadaver…”
Get full text
Journal Article -
10
Die proximale extraartikuläre Tibiafraktur
Published in Der Unfallchirurg (2002)Get full text
Journal Article -
11
Biomechanical investigations of different osteosynthesis procedures in the proximal tibia-introduction of a new measuring system
Published in Biomedizinische Technik (01-11-2003)“…In this article a new measuring system for biomechanical studies of various osteosynthesis procedures on the tibia is described. The paired tibias are…”
Get more information
Journal Article -
12
Off-bypass coronary bypass grafting via minithoracotomy using mechanical epicardial stabilization
Published in The Annals of thoracic surgery (01-06-1997)“…Minimally or less invasive surgical coronary revascularization has gained increasing interest along with new techniques and devices designed for easier and…”
Get full text
Journal Article Conference Proceeding -
13
Are angle-fixed implants with elastic properties advantageous for the internal fixation of proximal humerus fractures?
Published in Biomedizinische Technik (01-12-2004)“…There is a recent interest for the use of angle-fixed plates in the management of proximal humerus fractures. Rigid implants might be associated with an…”
Get more information
Journal Article -
14
Bilateral monitoring of cerebral oxygen saturation in aortic arch surgery
Published in Anästhesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie : AINS (01-06-2001)“…Cerebral ischemia with consecutive neurological damage is a typical complication in aortic arch surgery. Therefore, intraoperative neuromonitoring is of…”
Get more information
Journal Article -
15
Determination of frictional coefficients of different HIP-hemiendoprostheses against cadaveric acetabula
Published in Hip international (01-04-2004)“…The science concerning hip arthroplasty has mainly dealt with total endoprosthesis, whereas tribology measurement values of hemiendoprosthetic implants are…”
Get full text
Journal Article -
16
The HEPFIEx simulator, a device for determination of friction between femur head prosthesis and cartilage
Published in Biomedizinische Technik (01-03-2002)“…We describe a device designed to investigate friction between various femoral head prostheses and human acetabula. It enables not only the determination of…”
Get more information
Journal Article -
17
Friction in hip hemiendoprostheses. Review of literature and own model using cadaveric acetabula
Published in Hip international (01-04-2002)Get full text
Journal Article -
18
Transient low-frequency hypoacousia after spinal anaesthesia
Published in The Lancet (British edition) (03-09-1983)Get more information
Journal Article -
19
Wound infections after heart surgery interventions--a cost analysis
Published in Langenbecks Archiv fur Chirurgie. Supplement. Kongressband. Deutsche Gesellschaft fur Chirurgie. Kongress (1997)“…Decreasing financial resources in the health care system require effective cost management. For this reason and due to special modalities of reimbursement…”
Get more information
Journal Article -
20
The extraarticular proximal tibial fractures
Published in Der Unfallchirurg (01-10-2002)“…Operative stabilization of proximal tibial fractures by use of conventional osteosynthesis is still problematic. The choice of the osteosynthetic treatment is…”
Get full text
Journal Article