Search Results - "Matsuura, Taeko"
-
1
An initial systematic study of the linear energy transfer distributions of a proton beam under a transverse magnetic field
Published in Medical physics (Lancaster) (01-03-2022)“…Purpose To evaluate the biological effectiveness of magnetic resonance (MR)‐guided proton beam therapy, comprehensively characterizing the dose and…”
Get full text
Journal Article -
2
First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker
Published in Physics in medicine & biology (09-09-2021)“…Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning…”
Get more information
Journal Article -
3
Proton dose calculation based on converting dual-energy CT data to stopping power ratio (DEEDZ-SPR): a beam-hardening assessment
Published in Physics in medicine & biology (07-12-2020)“…To achieve an accurate stopping power ratio (SPR) prediction in particle therapy treatment planning, we previously proposed a simple conversion to the SPR from…”
Get more information
Journal Article -
4
Enhanced radiobiological effects at the distal end of a clinical proton beam: in vitro study
Published in Journal of radiation research (01-07-2014)“…In the clinic, the relative biological effectiveness (RBE) value of 1.1 has usually been used in relation to the whole depth of the spread-out Bragg-peak…”
Get full text
Journal Article -
5
A proton beam therapy system dedicated to spot-scanning increases accuracy with moving tumors by real-time imaging and gating and reduces equipment size
Published in PloS one (01-04-2014)“…A proton beam therapy (PBT) system has been designed which dedicates to spot-scanning and has a gating function employing the fluoroscopy-based…”
Get full text
Journal Article -
6
Ionoacoustic application of an optical hydrophone to detect proton beam range in water
Published in Medical physics (Lancaster) (01-04-2023)“…Background Proton range uncertainty has been the main factor limiting the ability of proton therapy to concentrate doses to tumors to their full potential…”
Get full text
Journal Article -
7
On-line range verification for proton beam therapy using spherical ionoacoustic waves with resonant frequency
Published in Scientific reports (23-11-2020)“…In contrast to conventional X-ray therapy, proton beam therapy (PBT) can confine radiation doses to tumours because of the presence of the Bragg peak. However,…”
Get full text
Journal Article -
8
Deformed dose restoration to account for tumor deformation and position changes for adaptive proton therapy
Published in Medical physics (Lancaster) (01-02-2023)“…Background Online adaptation during intensity‐modulated proton therapy (IMPT) can minimize the effect of inter‐fractional anatomical changes, but remains…”
Get full text
Journal Article -
9
Impact of Real-Time Image Gating on Spot Scanning Proton Therapy for Lung Tumors: A Simulation Study
Published in International journal of radiation oncology, biology, physics (01-01-2017)“…Purpose To investigate the effectiveness of real-time-image gated proton beam therapy for lung tumors and to establish a suitable size for the gating window…”
Get full text
Journal Article -
10
Technical note: Performance evaluation of volumetric imaging based on motion modeling by principal component analysis
Published in Medical physics (Lancaster) (01-02-2023)“…Purpose To quantitatively evaluate the achievable performance of volumetric imaging based on lung motion modeling by principal component analysis (PCA)…”
Get full text
Journal Article -
11
A novel range-verification method using ionoacoustic wave generated from spherical gold markers for particle-beam therapy: a simulation study
Published in Scientific reports (08-03-2019)“…This study proposes a novel alternative range-verification method for proton beam with acoustic waves generated from spherical metal markers. When proton beam…”
Get full text
Journal Article -
12
Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System
Published in International journal of radiation oncology, biology, physics (2016)“…Purpose To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using…”
Get full text
Journal Article -
13
Prediction of target position from multiple fiducial markers by partial least squares regression in real-time tumor-tracking radiation therapy
Published in Journal of radiation research (01-09-2021)“…Abstract The purpose of this work is to show the usefulness of a prediction method of tumor location based on partial least squares regression (PLSR) using…”
Get full text
Journal Article -
14
Real‐time CT image generation based on voxel‐by‐voxel modeling of internal deformation by utilizing the displacement of fiducial markers
Published in Medical physics (Lancaster) (01-09-2021)“…Purpose To show the feasibility of real‐time CT image generation technique utilizing internal fiducial markers that facilitate the evaluation of internal…”
Get full text
Journal Article -
15
Impact of a spatially dependent dose delivery time structure on the biological effectiveness of scanning proton therapy
Published in Medical physics (Lancaster) (01-01-2022)“…Purpose In the scanning beam delivery of protons, different portions of the target are irradiated with different linear energy transfer protons with various…”
Get full text
Journal Article -
16
An analytical dose‐averaged LET calculation algorithm considering the off‐axis LET enhancement by secondary protons for spot‐scanning proton therapy
Published in Medical physics (Lancaster) (01-07-2018)“…Purpose To evaluate the biological effects of proton beams as part of daily clinical routine, fast and accurate calculation of dose‐averaged linear energy…”
Get full text
Journal Article -
17
Evaluation of the relative biological effectiveness of spot-scanning proton irradiation in vitro
Published in Journal of radiation research (01-06-2016)“…Variations in relative biological effectiveness (RBE) from a fixed value of 1.1 are critical in proton beam therapy. To date, studies estimating RBE at…”
Get full text
Journal Article -
18
A Consistent Protocol Reveals a Large Heterogeneity in the Biological Effectiveness of Proton and Carbon-Ion Beams for Various Sarcoma and Normal-Tissue-Derived Cell Lines
Published in Cancers (15-04-2022)“…This study investigated variations in the relative biological effectiveness (RBE) values among various sarcoma and normal-tissue-derived cell lines (normal…”
Get full text
Journal Article -
19
Potential benefits of adaptive intensity‐modulated proton therapy in nasopharyngeal carcinomas
Published in Journal of applied clinical medical physics (01-01-2021)“…Purpose To investigate potential advantages of adaptive intensity‐modulated proton beam therapy (A‐IMPT) by comparing it to adaptive intensity‐modulated X‐ray…”
Get full text
Journal Article -
20
Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction
Published in Journal of radiation research (01-07-2021)“…Abstract In spot scanning proton therapy (SSPT), the spot position relative to the target may fluctuate through tumor motion even when gating the radiation by…”
Get full text
Journal Article