Search Results - "Martineau, Paul A."
-
1
Comparing a Portable Motion Analysis System against the Gold Standard for Potential Anterior Cruciate Ligament Injury Prevention and Screening
Published in Sensors (Basel, Switzerland) (01-03-2024)“…Knee kinematics during a drop vertical jump, measured by the Kinect V2 (Microsoft, Redmond, WA, USA), have been shown to be associated with an increased risk…”
Get full text
Journal Article -
2
The Apex of the Deep Cartilage: A Landmark and New Technique to Help Identify Femoral Tunnel Placement in Anterior Cruciate Ligament Reconstruction
Published in Arthroscopy (01-09-2015)“…Purpose The purpose of this study was to evaluate the apex of the deep cartilage (ADC) as a landmark to help guide femoral tunnel placement during anatomic…”
Get full text
Journal Article -
3
Defective bone repair in mast cell-deficient Cpa3Cre/+ mice
Published in PloS one (28-03-2017)“…In the adult skeleton, cells of the immune system interact with those of the skeleton during all phases of bone repair to influence the outcome. Mast cells are…”
Get full text
Journal Article -
4
Investigating Commercial Filaments for 3D Printing of Stiff and Elastic Constructs with Ligament-Like Mechanics
Published in Micromachines (Basel) (11-09-2020)“…The current gold standard technique for treatment of anterior cruciate ligament (ACL) injury is reconstruction with autograft. These treatments have a…”
Get full text
Journal Article -
5
A Nanoporous 3D-Printed Scaffold for Local Antibiotic Delivery
Published in Micromachines (Basel) (30-12-2023)“…Limitations of bone defect reconstruction include poor bone healing and osteointegration with acrylic cements, lack of strength with bone putty/paste, and poor…”
Get full text
Journal Article -
6
Is the Clock Face an Accurate, Precise, and Reliable Measuring Tool for Anterior Cruciate Ligament Reconstruction?
Published in Arthroscopy (01-07-2014)“…Purpose (1) To assess the use and practice of the clock face among surgeons who routinely perform anterior cruciate ligament (ACL) reconstructions, and (2) to…”
Get full text
Journal Article -
7
A Cadaveric Analysis of Tunnel Position Created Using Flexible Versus Rigid Instrumentation in a Single-Incision Distal Biceps Tendon Repair
Published in Arthroscopy (01-05-2014)“…Purpose This study was designed to determine whether the use of a flexible guide pin and reamer through an anterior single-incision approach would allow for a…”
Get full text
Journal Article -
8
An Arthroscopic Procedure for Restoration of Posterolateral Tibial Plateau Slope in Tibial Plateau Fracture Associated With Anterior Cruciate Ligament Injuries
Published in Arthroscopy techniques (Amsterdam) (01-09-2020)“…High-energy anterior cruciate ligament (high-energy ACL) injury, occurring in high-energy rotatory trauma of the knee, can accompany a unique fracture pattern…”
Get full text
Journal Article -
9
Central Versus Eccentric Internal Fixation of Acute Scaphoid Fractures
Published in The Journal of hand surgery (American ed.) (2013)“…Purpose To accurately calculate the cross-sectional area of typical scaphoid fracture patterns and compare the amount of fracture surface area available for…”
Get full text
Journal Article -
10
Can Surgeons Identify ACL Femoral Ridges Landmark and Optimal Tunnel Position? A 3D Model Study
Published in Arthroscopy, Sports Medicine, and Rehabilitation (01-08-2020)“…To examine the ability of surgeons to identify the osseous landmarks associated with the femoral anterior cruciate ligament (ACL) footprint and locate optimal…”
Get full text
Journal Article -
11
Three-Dimensional (3D) Animation and Calculation for the Assessment of Engaging Hill–Sachs Lesions With Computed Tomography 3D Reconstruction
Published in Arthroscopy, Sports Medicine, and Rehabilitation (01-02-2021)“…To dynamically assess for Hill–Sachs engagement with animated 3-dimensional (3D) shoulder models. We created 3D shoulder models from reconstructed computed…”
Get full text
Journal Article -
12
Insertion Profiles of 4 Headless Compression Screws
Published in The Journal of hand surgery (American ed.) (01-09-2013)“…Purpose In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge…”
Get full text
Journal Article -
13
Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Flexible Reamers
Published in Arthroscopy techniques (Amsterdam) (01-02-2018)“…Abstract Distal biceps tendon ruptures are treated operatively in active healthy individuals. Treatment consists of either single- or double-incision…”
Get full text
Journal Article -
14
Comparative Biomechanic Study of Flexor Tendon Repair Using FiberWire
Published in The Journal of hand surgery (American ed.) (01-05-2008)“…Purpose FiberWire, an increasingly popular suture material, allows for strong flexor tendon repair that may allow early mobilization. This study was designed…”
Get full text
Journal Article -
15
Suture Bridge Fixation for Tibial Eminence Fractures
Published in Arthroscopy (01-03-2013)Get full text
Journal Article -
16
A Prospective Evaluation of Femoral Tunnel Placement for Anatomic Anterior Cruciate Ligament Reconstruction Using 3-Dimensional Magnetic Resonance Imaging
Published in The American journal of sports medicine (01-01-2018)“…Background: The recent emphasis on anatomic reconstruction of the anterior cruciate ligament (ACL) is well supported by clinical and biomechanical research…”
Get full text
Journal Article -
17
Risk of Glove Perforation With Arthroscopic Knot Tying Using Different Surgical Gloves and High–Tensile Strength Sutures
Published in Arthroscopy (01-09-2013)“…Purpose To examine the risk of glove tears associated with arthroscopic knot tying using 4 commonly used high–tensile strength sutures and 2 different types of…”
Get full text
Journal Article -
18
Evaluating the Accuracy of Tibial Tunnel Placement After Anatomic Single-Bundle Anterior Cruciate Ligament Reconstruction
Published in The American journal of sports medicine (01-11-2019)“…Background: Anatomic anterior cruciate ligament (ACL) reconstruction improves knee kinematics and joint stability in symptomatic patients who have ACL…”
Get full text
Journal Article -
19
Comparing novel smartphone pose estimation frameworks with the Kinect V2 for knee tracking during athletic stress tests
Published in International journal for computer assisted radiology and surgery (01-07-2024)“…Purpose To compare the accuracy of the Microsoft Kinect V2 with novel pose estimation frameworks, in assessing knee kinematics during athletic stress tests,…”
Get full text
Journal Article -
20
Drill wobble – effect on femoral tunnel aperture during anterior cruciate ligament reconstruction
Published in Journal of experimental orthopaedics (01-12-2016)“…Background In anterior cruciate ligament reconstruction performed using cortical button fixation on the femur, we have observed a “wobble” effect that can…”
Get full text
Journal Article