Search Results - "Marois, Y"
-
1
Characterization of plasma proteins adsorbed onto biomaterials by MALDI-TOFMS
Published in Biomaterials (01-08-2000)“…The analysis of plasma proteins adsorbed onto a polyurethane (PU) biomaterial was performed using matrix-assisted laser desorption/ionization time-of-flight…”
Get full text
Journal Article -
2
First-Generation Aortic Endografts: Analysis of Explanted Stentor Devices from the EUROSTAR Registry
Published in Journal of endovascular therapy (01-04-2000)“…Purpose: To examine the structure and healing characteristics of chronically implanted Stentor endografts that were explanted due to migration, endoleak,…”
Get full text
Journal Article -
3
An albumin-coated polyester arterial graft: in vivo assessment of biocompatibility and healing characteristics
Published in Biomaterials (1996)“…The albumin-coated vascular graft (ACG) and its uncoated polyester substrate, the Vascular ® II (V-II), were evaluated in terms of biocompatibility and…”
Get full text
Journal Article -
4
Vascugraft ® polyurethane arterial prosthesis as femoro-popliteal and femoro-peroneal bypasses in humans: pathological, structural and chemical analyses of four excised grafts
Published in Biomaterials (1997)“…Following positive results obtained in in vitro studies and in vivo implantations in animals, a clinical trial using the Vascugraft ® polyurethane arterial…”
Get full text
Journal Article -
5
Endovascular Repair of Thoracic Aortic Aneurysm in Dogs: Evaluation of a Nitinol-Polyester Self-Expanding Stent-Graft
Published in Journal of endovascular therapy (01-02-2000)“…Purpose: To validate the ease of deployment and in vivo healing performance of a nitinol-polyester self-expanding stent-graft using a canine thoracic aortic…”
Get full text
Journal Article -
6
In vivo magnetic resonance imaging and relaxometry study of a porous hydrogel implanted in the trapezius muscle of rabbits
Published in Tissue engineering (01-06-2000)“…In vivo magnetic resonance imaging (MRI) and relaxometry were performed to assess noninvasively the tissue reaction and the biological integration of hydrogels…”
Get more information
Journal Article -
7
The benefits of fluoropassivation of polyester arterial prostheses as observed in a canine model
Published in ASAIO journal (1992) (01-07-1994)“…The effect of treating the surface of a polyester vascular prosthesis with a novel fluoropolymer before sealing the graft with gelatin has been evaluated in a…”
Get more information
Journal Article -
8
Benefit from high intrarenal levels of gentamicin in the treatment of E. coli pyelonephritis
Published in Kidney international (01-10-1986)“…Benefit from high intrarenal levels of gentamicin in the treatment of E. coli pyelonephritis. The importance of high intrarenal levels of gentamicin on the…”
Get full text
Journal Article -
9
Autoradiographic study of tobramycin uptake by proximal and distal tubules of normal and pyelonephritic rats
Published in Antimicrobial Agents and Chemotherapy (01-09-1987)“…Classifications Services AAC Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit…”
Get full text
Journal Article -
10
The gelweave polyester arterial prosthesis
Published in Canadian Journal of Surgery (01-08-1995)“…To determine the effect of the gelatin coating on the efficacy of Gelweave, a new gelatin-sealed woven polyester graft material, as an arterial prosthesis…”
Get full text
Journal Article -
11
Autoradiography of tobramycin uptake by the proximal and distal tubules of normal and endotoxin-treated rats
Published in Antimicrobial Agents and Chemotherapy (01-06-1986)“…Classifications Services AAC Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit…”
Get full text
Journal Article -
12
Analysis of retrieved polymer fiber based replacements for the ACL
Published in Biomaterials (01-12-2000)“…The present retrospective analysis of 117 surgically excised anterior cruciate ligament (ACL) prostheses was designed to elucidate the etiology and mechanisms…”
Get full text
Journal Article -
13
Measurement of CD11/CD18 integrin expression on the polymorphonuclear cell surface after incubation with synthetic vascular prostheses
Published in ASAIO journal (1992) (01-07-1994)“…Polymorphonuclear (PMN) cell activation in the presence of synthetic vascular grafts was studied by using flow cytometry to measure CD11/CD18 leukocyte…”
Get more information
Journal Article -
14
Noninvasive follow-up of tissue encapsulation of foreign materials. Are magnetic resonance imaging and spectroscopy breakthroughs?
Published in ASAIO journal (1992) (01-07-1995)“…The development of sensitive and noninvasive magnetic resonance (MR) techniques for the long- and short-term evaluation of vascular prostheses requires…”
Get more information
Journal Article -
15
Hydrophilic polyurethane versus autologous femoral vein as substitutes in the femoral arteries of dogs: quantification of platelets and fibrin deposits
Published in Biomaterials (01-03-1989)“…Hydrophilic, microporous polyurethane vascular prostheses displayed good mechanical characteristics and the behaviour in vitro was excellent. The in-vivo…”
Get more information
Journal Article -
16
Histopathologic findings in synthetic and biologic explanted grafts used in peripheral arterial reconstruction
Published in ASAIO journal (1992) (01-07-1994)“…Surgically explanted vascular grafts, including 47 autografts, 14 allografts, 103 chemically processed human umbilical vein (HUV) grafts, and 406…”
Get more information
Journal Article -
17
Evaluation of biodegradable synthetic scaffold coated on arterial prostheses implanted in rat subcutaneous tissue
Published in Biomaterials (01-12-2005)“…Polyester arterial prostheses impregnated with various synthetic biodegradable materials and with gelatin were implanted subcutaneously in rats for 3–180 days…”
Get full text
Journal Article -
18
T lymphocyte modification with the UTA microporous polyurethane vascular prosthesis: in vivo studies in rats
Published in Clinical and investigative medicine (01-04-1992)“…Sequential quantification of blood T cell subsets by immunocytofluorometry was used to investigate the immune response of microporous polyurethane vascular…”
Get more information
Journal Article -
19
A new bioactive molecule for improving vascular graft patency: exploratory trials in dogs
Published in Clinical and investigative medicine (01-08-1992)“…Myxalin is a new bioactive molecule that we have isolated from the culture medium of Myxococcus xanthus, a non-pathogenic Gram negative bacterium. This…”
Get more information
Journal Article -
20
Comparison of processed bovine internal mammary arteries and autologous veins as arterial femoral substitutes in dogs: blood compatibility and pathological characteristics
Published in Canadian journal of surgery (01-05-1989)“…This study was undertaken to compare the chemically processed internal mammary artery (BIMA) and the autologous femoral vein as arterial grafts. The BIMA…”
Get more information
Journal Article