Search Results - "Manke, Christoph"
-
1
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
Published in Journal of magnetic resonance imaging (01-01-2001)“…The interest in performing vascular interventions under magnetic resonance (MR) guidance has initiated the evaluation of the potential hazard of long…”
Get full text
Journal Article -
2
Peripheral arterial balloon angioplasty: effect of short versus long balloon inflation times on the morphologic results
Published in Journal of vascular and interventional radiology (01-04-2002)“…To evaluate the effect of different balloon inflation times on angiographic results in peripheral angioplasty. Seventy-four infrainguinal arteriosclerotic…”
Get more information
Journal Article -
3
Aktueller Stand der endovaskulären Behandlung von Shuntdysfunktionen
Published in Gefässchirurgie (01-12-2023)“…Zusammenfassung Shuntdysfunktionen umfassen Abnormalitäten des Gefäßzugangs, die eine adäquate Dialyse verhindern bzw. den Patienten gefährden. Die häufigste…”
Get full text
Journal Article -
4
Percutaneous Aspiration Thrombectomy for the Treatment of Arterial Thromboembolic Occlusions Following Percutaneous Transluminal Angioplasty
Published in Cardiovascular and interventional radiology (01-02-2015)“…Purpose This study was designed to evaluate the technical success and the early clinical outcome of patients undergoing percutaneous aspiration thrombectomy…”
Get full text
Journal Article -
5
Radiation exposure in whole-body computed tomography of multiple trauma patients: Bearing devices and patient positioning
Published in Injury (01-01-2012)“…Abstract Background Whole-body computed tomography (WBCT) plays an important role in the management of severely injured patients. We evaluated the radiation…”
Get full text
Journal Article -
6
Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease
Published in Cardiovascular and interventional radiology (01-06-2010)“…Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16…”
Get full text
Journal Article -
7
Dose effects and image quality: Is there any influence by bearing devices in whole-body computed tomography in trauma patients?
Published in Injury (01-01-2014)“…Abstract Background Stable bearing devices are often utilized by prehospital first responders in modern management of severely injured patients. It is not…”
Get full text
Journal Article -
8
Spinal Metastases from Renal Cell Carcinoma: Effect of Preoperative Particle Embolization on Intraoperative Blood Loss
Published in American journal of neuroradiology : AJNR (01-05-2001)“…Surgical repair of spinal metastases from renal origin is often complicated by excessive bleeding. The purpose of this study was to assess the effect of…”
Get full text
Journal Article -
9
Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents
Published in Radiology (01-10-2000)“…To evaluate signal intensity changes influencing assessment of stent patency at contrast material-enhanced magnetic resonance (MR) angiography. By using an in…”
Get more information
Journal Article -
10
MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study
Published in Radiology (01-05-2001)“…To assess the feasibility of magnetic resonance (MR) imaging-guided stent placement in iliac arterial stenoses. Thirteen patients with 14 iliac arterial…”
Get more information
Journal Article -
11
Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses
Published in Radiology (01-08-2001)“…Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal…”
Get more information
Journal Article -
12
Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of the Carotid Arteries: Diagnostic Accuracy and Inter-Observer Variability Compared With Selective Catheter Angiography
Published in Investigative radiology (01-10-2002)“…Lenhart M, Framme N, Völk M, et al. Time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteriesdiagnostic accuracy and…”
Get full text
Journal Article -
13
Time-Resolved Contrast-Enhanced MR Angiography of Renal Artery Stenosis: Diagnostic Accuracy and Interobserver Variability
Published in American journal of roentgenology (1976) (01-06-2000)“…The purpose of this study was to evaluate diagnostic accuracy and interobserver variability of time-resolved three-dimensional gadolinium-enhanced MR…”
Get full text
Journal Article -
14
Corrosion of tungsten coils after peripheral vascular embolization therapy: Influence on outcome and tungsten load
Published in Catheterization and cardiovascular interventions (01-07-2004)“…The purpose of this study was to evaluate coil corrosion and the long‐term outcome after peripheral vascular embolization therapy performed with tungsten…”
Get full text
Journal Article -
15
Pain in femoral arteriography. A double-blind, randomized, clinical study comparing safety and efficacy of the iso-osmolar iodixanol 270 mgI/ml and the low-osmolar iomeprol 300 mgI/ml in 9 European centers
Published in Acta radiologica (1987) (01-11-2003)“…To compare the injection-associated pain and heat sensation after administration of the iso-osmolar contrast medium (IOCM) iodixanol (Visipaque trade mark 270…”
Get more information
Journal Article -
16
Is Unprotected Carotid Stenting Safe?
Published in Clinical neuroradiology (Munich) (01-09-2006)“…So far, there is no proof that protection systems reduce the risk of cerebral embolism in patients undergoing stent-assisted angioplasty of the carotid artery…”
Get full text
Journal Article -
17
Appearance of Vascular Stents in Computed Tomographic Angiography: In Vitro Examination of 14 Different Stent Types
Published in Investigative radiology (01-11-2001)“…Strotzer M, Lenhart M, Butz B, et al. Appearance of vascular stents in computed tomographic angiographyIn vitro examination of 14 different stent types. Invest…”
Get full text
Journal Article -
18
Intraarterial MR angioplasty in iliac arterial stenosis
Published in Radiology (01-03-2002)Get more information
Journal Article -
19
Magnetic Resonance Monitoring of Stent Deployment: In Vitro Evaluation of Different Stent Designs and Stent Delivery Systems
Published in Investigative radiology (01-06-2000)“…Manke C, Nitz WR, Lenhart M, et al. Magnetic resonance monitoring of stent deploymentIn vitro evaluation of different stent designs and stent delivery systems…”
Get full text
Journal Article -
20
Flat-Panel X-Ray Detector Using Amorphous Silicon Technology: Reduced Radiation Dose for the Detection of Foreign Bodies
Published in Investigative radiology (01-07-1997)“…RATIONALE AND OBJECTIVESThe authors evaluate a new flat-panel x-ray detector (FD) with respect to foreign body detection and reduction of radiation dose…”
Get full text
Journal Article