Search Results - "Manglos, S H"

Refine Results
  1. 1

    Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT by Manglos, S H, Gagne, G M, Krol, A, Thomas, F D, Narayanaswamy, R

    Published in Physics in medicine & biology (01-07-1995)
    “…An iterative algorithm is presented for accelerated reconstruction of cone beam transmission CT data (CBCT). CBCT supplies an attenuation map for SPECT…”
    Get more information
    Journal Article
  2. 2

    Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects by Manglos, S H

    Published in Physics in medicine & biology (01-03-1992)
    “…Transverse image truncation can be a serious problem for human imaging using cone-beam transmission CT (CB-CT) implemented on a conventional rotating gamma…”
    Get more information
    Journal Article
  3. 3

    Persistent pain inhibits contralateral somatosensory cortical activity in humans by Apkarian, A V, Stea, R A, Manglos, S H, Szeverenyi, N M, King, R B, Thomas, F D

    Published in Neuroscience letters (22-06-1992)
    “…To assess cortical activity during pain perception, regional cerebral blood flow (rCBF) studies were done in humans using single photon emission computed…”
    Get more information
    Journal Article
  4. 4

    Phantom Study of Breast Tissue Attenuation in Myocardial Imaging by Manglos, Stephen H, Thomas, F. Deaver, Gagne, George M, Hellwig, Bradford J

    Published in The Journal of nuclear medicine (1978) (01-06-1993)
    “…The attenuation of photons by the breasts and other soft tissue overlying the chest may decrease the diagnostic accuracy of SPECT myocardial imaging. In this…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Experimentally measured scatter fractions and energy spectra as a test of Monte Carlo simulations by Manglos, S H, Floyd, C E, Jaszczak, R J, Greer, K L, Harris, C C, Coleman, R E

    Published in Physics in medicine & biology (01-03-1987)
    “…A method for the validation of Monte Carlo photon transport calculations is presented, with particular emphasis on the scatter component of such calculations…”
    Get more information
    Journal Article
  7. 7

    Cone-Beam Transmission Computed Tomography for Nonuniform Attenuation Compensation of SPECT Images by Manglos, Stephen H, Bassano, Daniel A, Thomas, F. Deaver

    Published in The Journal of nuclear medicine (1978) (01-09-1991)
    “…This paper develops and tests cone-beam transmission computed tomography (CB-CT) for attenuation compensation of SPECT images. CB-CT was implemented on a…”
    Get full text
    Journal Article
  8. 8

    Imaging of the Human Torso Using Cone-Beam Transmission CT Implemented on a Rotating Gamma Camera by Manglos, Stephen H, Bassano, Daniel A, Thomas, F. Deaver, Grossman, Zachary D

    Published in The Journal of nuclear medicine (1978) (01-01-1992)
    “…Radionuclide transmission CT generated on a rotating gamma camera can improve SPECT imaging by providing attenuation maps for attenuation compensation and for…”
    Get full text
    Journal Article
  9. 9
  10. 10

    Nonisotropic Attenuation in SPECT: Phantom Tests of Quantitative Effects and Compensation Techniques by Manglos, Stephen H, Jaszczak, Ronald J, Floyd, Carey E, Hahn, Leszek J, Greer, Kim L, Coleman, R. Edward

    Published in The Journal of nuclear medicine (1978) (01-10-1987)
    “…A quantitative study of nonisotropic attenuation in SPECT imaging is presented. The study includes a case where the spatial distribution of the attenuation…”
    Get full text
    Journal Article
  11. 11

    An EM algorithm for estimating SPECT emission and transmission parameters from emission data only by Krol, A., Bowsher, J.E., Manglos, S.H., Feiglin, D.H., Tornai, M.P., Thomas, F.D.

    Published in IEEE transactions on medical imaging (01-03-2001)
    “…A maximum-likelihood (ML) expectation-maximization (EM) algorithm (called EM-IntraSPECT) is presented for simultaneously estimating single photon emission…”
    Get full text
    Journal Article
  12. 12

    Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection by Jaszczak, R J, Floyd, Jr, C E, Manglos, S H, Greer, K L, Coleman, R E

    Published in Medical physics (Lancaster) (01-07-1986)
    “…This paper presents an analysis of two cone beam configurations (having focal lengths of 40 and 60 cm) for the acquisition of single photon emission computed…”
    Get more information
    Journal Article
  13. 13

    Noise characteristics for cone beam collimators: a comparison with parallel hole collimator by Hahn, L J, Jaszczak, R J, Gullberg, G T, Floyd, C E, Manglos, S H, Greer, K L, Coleman, R E

    Published in Physics in medicine & biology (01-05-1988)
    “…In order to evaluate the properties of a cone beam (CB) collimator and three-dimensional filtered backprojection algorithm, the noise characteristics of this…”
    Get more information
    Journal Article
  14. 14

    Practical evaluation of several cone beam orbits for SPECT by Manglos, S.H., Smith, B.D.

    Published in IEEE transactions on nuclear science (01-08-1993)
    “…Several alternative orbits have been suggested for cone beam single photon emission computed tomography (SPECT), since the standard circular orbit provides…”
    Get full text
    Journal Article Conference Proceeding
  15. 15

    Detection nonuniformity measurements and corrections for cone beam transmission CT on a gamma camera by Manglos, S H, Capone, R B, Bassano, D A

    Published in Medical physics (Lancaster) (01-03-1992)
    “…Cone beam transmission CT (CB-CT) improves SPECT imaging by providing high-quality attenuation maps for attenuation compensation and for correlated SPECT and…”
    Get more information
    Journal Article
  16. 16

    Attenuation compensation of cone beam SPECT images using maximum likelihood reconstruction by Manglos, S.H., Thomas, F.D., Capone, R.B.

    Published in IEEE transactions on medical imaging (01-03-1991)
    “…Attenuation compensation for cone beam single-photon emission computed tomography (SPECT) imaging is performed by cone beam maximum likelihood reconstruction…”
    Get full text
    Journal Article
  17. 17

    Weighted backprojection implemented with a non-uniform attenuation map for improved SPECT quantitation by Manglos, S.H., Jaszczak, R.J., Floyd, C.E.

    Published in IEEE transactions on nuclear science (01-02-1988)
    “…A method is developed to improve quantitation in single-photon-emission computed tomography (SPECT) imaging by using an attenuation compensation method that…”
    Get full text
    Journal Article
  18. 18

    Compensation for collimator divergence in SPECT using inverse Monte Carlo reconstruction by Floyd, C.E., Jaszczak, R.J., Manglos, S.H., Coleman, R.E.

    Published in IEEE transactions on nuclear science (01-02-1988)
    “…The inverse Monte Carlo (IMC) reconstruction algorithm achieved compensation for two degrading collimator effects in SPECT (single-photon-emission computed…”
    Get full text
    Journal Article
  19. 19

    Maximum likelihood reconstruction for cone beam SPECT with camera tilt by Manglos, S.H., Jaszczak, R.J., McAfee, J.G.

    Published in IEEE transactions on nuclear science (01-02-1989)
    “…Iterative maximum-likelihood (ML) reconstruction techniques are extended to the cone-beam SPECT (single-photon-emission computed tomography) geometry with the…”
    Get full text
    Journal Article
  20. 20

    Attenuation maps for SPECT determined using cone beam transmission computed tomography by Manglos, S.H., Bassano, D.A., Duxbury, C.E., Capone, R.B.

    “…A novel method for measuring nonuniform attenuation maps is presented. A cone beam geometry CT (computed tomography) scan acquired on a standard rotating gamma…”
    Get full text
    Journal Article Conference Proceeding